Dalila Mateus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Dalila Mateus has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Clivio
Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona, Switzerland
1 shared publication - Antonella Fogliata
Humanitas Research Hospital IRCCS Radiotherapy and Radiosurgery Dept Milan‐Rozzano Italy
1 shared publication - Carlo Greco
Department of Radiation Oncology, Champalimaud Centre for the Unknown, Lisbon, Portugal
1 shared publication - Eugenio Vanetti
Radiation Oncology Department, Medical Physics Unit, IOSI, Oncology Institute of Southern Switzerland, Bellinzona, Switzerland
1 shared publication - Giorgia Nicolini
Oncology Institute of Southern Switzerland, Medical Physics Unit, Bellinzona, Switzerland
1 shared publication - Joep Stroom
Champalimaud Foundation, Radiation Oncology, Lisbon, Portugal
1 shared publication
Latest Publications
- Open Access
- 5 September 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 1-9
On the robustness of VMAT-SABR treatment plans against isocentre positioning uncertainties
To appraise the robustness of VMAT dose distributions against uncertainties in the positioning of the patients when single fraction SABRT treatments are planned. A set of 18 patients (8 lung, 5 brain, 5 spinal or para-spinal) treated with VMAT in a single fraction of 24Gy were retrospectively analyzed. All approved plans were re-calculated by applying shifts to the isocentre of ±0.5, ±1, ±1.5, ±2 and ±3 mm along the primary X, Y and Z axes. Dose calculations were performed with the AAA and the Acuros engines. Quantitative analysis of DVH was performed on a total of 36 references (18 patients with AAA, 18 with Acuros) and 1080 re-calculated plans to measure the potential degree of deterioration of the plans according to the simulated errors. The dose to the CTV was essentially not affected by the isocenter shifts in all cases. Concerning PTV, The main impact was observed on the near-to-minimum dose D99%. No relevant impact was observed on organs at risk in the case of lung patients. In the case of patients treated in the spinal or para-spinal region, the near-to-maximum dose to the spine showed, in the worst scenario, referring to Acuros calculation, a potential average increase of 0.3Gy with a maximum of 1.9Gy (from 10.3 to 12.2 Gy) or 18%. This was partially mitigated to 12% with 1 mm and to 5% with 0.5 mm shifts. The study showed that shifts in the position of the isocenter as large as 3 mm tend to have modest impacts on the quality of the VMAT plans, scored by means of conventional DVH parameters. From the data shown, the VMAT approach should be considered adequately robust for single fraction SABR.
- 5 September 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 1-9
Open AccessOn the robustness of VMAT-SABR treatment plans against isocentre positioning uncertainties
To appraise the robustness of VMAT dose distributions against uncertainties in the positioning of the patients when single fraction SABRT treatments are planned. A set of 18 patients (8 lung, 5 brain, 5 spinal or para-spinal) treated with VMAT in a single fraction of 24Gy were retrospectively analyzed. All approved plans were re-calculated by applying shifts to the isocentre of ±0.5, ±1, ±1.5, ±2 and ±3 mm along the primary X, Y and Z axes. Dose calculations were performed with the AAA and the Acuros engines. Quantitative analysis of DVH was performed on a total of 36 references (18 patients with AAA, 18 with Acuros) and 1080 re-calculated plans to measure the potential degree of deterioration of the plans according to the simulated errors. The dose to the CTV was essentially not affected by the isocenter shifts in all cases. Concerning PTV, The main impact was observed on the near-to-minimum dose D99%. No relevant impact was observed on organs at risk in the case of lung patients. In the case of patients treated in the spinal or para-spinal region, the near-to-maximum dose to the spine showed, in the worst scenario, referring to Acuros calculation, a potential average increase of 0.3Gy with a maximum of 1.9Gy (from 10.3 to 12.2 Gy) or 18%. This was partially mitigated to 12% with 1 mm and to 5% with 0.5 mm shifts. The study showed that shifts in the position of the isocenter as large as 3 mm tend to have modest impacts on the quality of the VMAT plans, scored by means of conventional DVH parameters. From the data shown, the VMAT approach should be considered adequately robust for single fraction SABR.