Air Trapping: Comparison of Standard-Dose and Simulated Low-Dose Thin-Section CT Techniques
Authors:
- Alexander A. BankierABAlexander A. Bankier
- Cornelia Schaefer-ProkopCSCornelia Schaefer-Prokop
- Viviane De MaertelaerVMViviane De Maertelaer
- Denis TackDTDenis Tack
- Peter JakschPJPeter Jaksch
- Walter KlepetkoWKWalter Klepetko
- Pierre Alain GevenoisPGPierre Alain Gevenois
- 1 March 2007
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (3) , 898-906
Abstract
To prospectively investigate the effect of radiation dose reduction on the visual quantification of air trapping at expiratory thin-section computed tomography (CT). In this ethical committee-approved study, 27 lung transplant recipients (12 women, 15 men; mean age, 54 years +/- 2 [standard error of the mean]) underwent expiratory thin-section CT at 140 kVp and 80 mAs (effective). All patients gave written informed consent. Dose reduction corresponding to 60, 40, and 20 mAs (effective) was simulated. The extent of air trapping in both original and dose-reduced studies was scored by three independent readers. The effects of tube current-time product, reader, reading session, and body mass index on average air trapping scores were assessed with analysis of variance. Agreements between and within observers were assessed with a weighted kappa statistic. Subjective scores for diagnostic confidence were attributed (3 = high, 2 = medium, 1 = low), and their means were calculated for each tube current-time product value. No significant effect on average air trapping scores as a result of tube current-time product (P = .222), reader (P = .217), reading session (P = .705), or body mass index (P = .505) could be detected. At 80 mAs, agreement between readers was excellent; agreement decreased to good or moderate at lower tube current settings. Agreement within readers decreased with a decrease in dose but remained good even at 20 mAs. Confidence also decreased, with mean scores decreasing from 2.33 +/- 0.73 (standard deviation) to 1.04 +/- 0.19 when dose decreased. At 140 kVp, the tube current-time product can be reduced from 80 to 20 mAs without impairing the visual quantification of air trapping at expiratory thin-section CT and with acceptable decreases in agreement between and within readers and in reader confidence.Keywords
This publication has 34 references indexed in Scilit:
- Image Quality from High-Resolution CT of the Lung: Comparison of Axial Scans and of Sections Reconstructed from Volumetric Data Acquired Using MDCTAmerican Journal of Roentgenology, 2005
- Radiologic and Pathologic Features of BronchiolitisAmerican Journal of Roentgenology, 2005
- Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image QualityAmerican Journal of Roentgenology, 2002
- Common Terminology for Single and Multislice Helical CTAmerican Journal of Roentgenology, 2001
- Lung TransplantationNew England Journal of Medicine, 1999
- Air trapping on expiratory high-resolution CT scans in the absence of inspiratory scan abnormalities: correlation with pulmonary function tests and differential diagnosis.American Journal of Roentgenology, 1998
- Low-Dose Spiral Computed Tomography of the ThoraxInvestigative Radiology, 1998
- CT of the chest: minimal tube current required for good image quality with the least radiation dose.American Journal of Roentgenology, 1995
- High-resolution computed tomography of the lung: Normal and abnormal anatomySeminars in Roentgenology, 1991
- Weighted kappa: Nominal scale agreement provision for scaled disagreement or partial credit.Psychological Bulletin, 1968