Alexander A. Bankier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander A. Bankier has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Qun Chen
Department of Radiology, New York University School of Medicine, New York, New York, USA
2 shared publicationsRobert R. Edelman
MRI Research, Department of Radiology, Northwestern University Medical School, Evanston, Illinois, USA
2 shared publicationsCornelia Schaefer-Prokop
1 shared publicationDenis Tack
1 shared publicationH. Imhof
Medizinische Universität
1 shared publicationKlaus D. Hagspiel
Department of Radiology, Health Sciences Center, University of Virginia, Charlottesville, Virginia
1 shared publication
Latest Publications
- 1 May 2007
- Published by Springer Nature in Der Radiologe
- Vol. 47 (5) , 383
Interstitielle Lungenerkrankungen
- 1 May 2007
- Published by Springer Nature in Der Radiologe
- Vol. 47 (5) , 383
Interstitielle Lungenerkrankungen
- 1 March 2007
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (3) , 898-906
Air Trapping: Comparison of Standard-Dose and Simulated Low-Dose Thin-Section CT Techniques
To prospectively investigate the effect of radiation dose reduction on the visual quantification of air trapping at expiratory thin-section computed tomography (CT). In this ethical committee-approved study, 27 lung transplant recipients (12 women, 15 men; mean age, 54 years +/- 2 [standard error of the mean]) underwent expiratory thin-section CT at 140 kVp and 80 mAs (effective). All patients gave written informed consent. Dose reduction corresponding to 60, 40, and 20 mAs (effective) was simulated. The extent of air trapping in both original and dose-reduced studies was scored by three independent readers. The effects of tube current-time product, reader, reading session, and body mass index on average air trapping scores were assessed with analysis of variance. Agreements between and within observers were assessed with a weighted kappa statistic. Subjective scores for diagnostic confidence were attributed (3 = high, 2 = medium, 1 = low), and their means were calculated for each tube current-time product value. No significant effect on average air trapping scores as a result of tube current-time product (P = .222), reader (P = .217), reading session (P = .705), or body mass index (P = .505) could be detected. At 80 mAs, agreement between readers was excellent; agreement decreased to good or moderate at lower tube current settings. Agreement within readers decreased with a decrease in dose but remained good even at 20 mAs. Confidence also decreased, with mean scores decreasing from 2.33 +/- 0.73 (standard deviation) to 1.04 +/- 0.19 when dose decreased. At 140 kVp, the tube current-time product can be reduced from 80 to 20 mAs without impairing the visual quantification of air trapping at expiratory thin-section CT and with acceptable decreases in agreement between and within readers and in reader confidence.
- 1 March 2007
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (3) , 898-906
Air Trapping: Comparison of Standard-Dose and Simulated Low-Dose Thin-Section CT Techniques
To prospectively investigate the effect of radiation dose reduction on the visual quantification of air trapping at expiratory thin-section computed tomography (CT). In this ethical committee-approved study, 27 lung transplant recipients (12 women, 15 men; mean age, 54 years +/- 2 [standard error of the mean]) underwent expiratory thin-section CT at 140 kVp and 80 mAs (effective). All patients gave written informed consent. Dose reduction corresponding to 60, 40, and 20 mAs (effective) was simulated. The extent of air trapping in both original and dose-reduced studies was scored by three independent readers. The effects of tube current-time product, reader, reading session, and body mass index on average air trapping scores were assessed with analysis of variance. Agreements between and within observers were assessed with a weighted kappa statistic. Subjective scores for diagnostic confidence were attributed (3 = high, 2 = medium, 1 = low), and their means were calculated for each tube current-time product value. No significant effect on average air trapping scores as a result of tube current-time product (P = .222), reader (P = .217), reading session (P = .705), or body mass index (P = .505) could be detected. At 80 mAs, agreement between readers was excellent; agreement decreased to good or moderate at lower tube current settings. Agreement within readers decreased with a decrease in dose but remained good even at 20 mAs. Confidence also decreased, with mean scores decreasing from 2.33 +/- 0.73 (standard deviation) to 1.04 +/- 0.19 when dose decreased. At 140 kVp, the tube current-time product can be reduced from 80 to 20 mAs without impairing the visual quantification of air trapping at expiratory thin-section CT and with acceptable decreases in agreement between and within readers and in reader confidence.
- Open Access
- 6 January 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 23 (2) , 115-122
Gravity‐dependent signal gradients on MR images of the lung in supine and prone positions: A comparison with isogravitational signal variability
Purpose: To investigate the tendency of proton MR signal intensity (SI) gradients to be steeper in the supine than in the prone body position, and to quantify the relation between gravity‐related and isogravitational changes of SI on proton MR images of the lung.Materials and Methods: In eight healthy volunteers, MR images were obtained in the supine and prone positions using a multiple inversion recovery turbo spin‐echo (TSE) sequence. The variation in SI along the gravity‐dependent direction and within isogravitational planes was measured on a pixel‐by‐pixel basis. Ratios of slopes were calculated for comparisons among volunteers. Comparisons of ratios were made using Fisher's exact test. Isogravitational variability was compared with the mean SI, the signal‐to‐noise ratio (SNR), and the image noise.Results: The average ratios of slopes showed that the overall SI gradient was steeper in the supine than the prone position, with a substantial difference in the supine/prone ratios between inspiration (1.21) and expiration (1.72). In both the supine and prone positions, gravity‐dependent gradients were steeper in expiration than in inspiration (P = 0.001). The SI variability along the gravitational direction was larger than the isogravitational variability. The isogravitational variability in turn was larger than the image noise but smaller than the mean SI of the MR images.Conclusion: Gravity‐dependent gradients in proton MR SI are steeper in the supine than in the prone position. The magnitudes of these gradients were larger than the isogravitational signal variability, showing that MRI is sensitive to gravitationally induced effects. J. Magn. Reson. Imaging 2006.
- 6 January 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 23 (2) , 115-122
Open AccessGravity‐dependent signal gradients on MR images of the lung in supine and prone positions: A comparison with isogravitational signal variability
Purpose: To investigate the tendency of proton MR signal intensity (SI) gradients to be steeper in the supine than in the prone body position, and to quantify the relation between gravity‐related and isogravitational changes of SI on proton MR images of the lung.Materials and Methods: In eight healthy volunteers, MR images were obtained in the supine and prone positions using a multiple inversion recovery turbo spin‐echo (TSE) sequence. The variation in SI along the gravity‐dependent direction and within isogravitational planes was measured on a pixel‐by‐pixel basis. Ratios of slopes were calculated for comparisons among volunteers. Comparisons of ratios were made using Fisher's exact test. Isogravitational variability was compared with the mean SI, the signal‐to‐noise ratio (SNR), and the image noise.Results: The average ratios of slopes showed that the overall SI gradient was steeper in the supine than the prone position, with a substantial difference in the supine/prone ratios between inspiration (1.21) and expiration (1.72). In both the supine and prone positions, gravity‐dependent gradients were steeper in expiration than in inspiration (P = 0.001). The SI variability along the gravitational direction was larger than the isogravitational variability. The isogravitational variability in turn was larger than the image noise but smaller than the mean SI of the MR images.Conclusion: Gravity‐dependent gradients in proton MR SI are steeper in the supine than in the prone position. The magnitudes of these gradients were larger than the isogravitational signal variability, showing that MRI is sensitive to gravitationally induced effects. J. Magn. Reson. Imaging 2006.
- Open Access
- 7 June 2000
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 43 (6) , 793-795
Imaging pulmonary blood flow and perfusion using phase‐sensitive selective inversion recovery
- 7 June 2000
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 43 (6) , 793-795
Open AccessImaging pulmonary blood flow and perfusion using phase‐sensitive selective inversion recovery