The use of tourniquet may influence the cement mantle thickness under the tibial implant during total knee arthroplasty
- 8 January 2019
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 29 (4) , 869-875
Abstract
Introduction It is still unknown whether the creation of blood-free surfaces by the use of tourniquet during total knee arthroplasty (TKA) has an influence on cement penetration and on implant fixation. The aim of this study is to evaluate the cement mantle under tibial component and the occurrence of progressive radiolucent lines (RLLs) according to the use of tourniquet in primary TKA. Materials and methods Fifty patients undergone TKA without the use of tourniquet (group 1) were well matched regarding baseline characteristics with 50 TKAs with the use of tourniquet (group 2). Patients were followed up prospectively. Cement mantle thickness was measured using immediate postoperative X-rays, and the occurrence of progressive radiolucency was finally evaluated in 3-year follow-up. New Knee Society Score (KSS) was used to compare clinical outcome between groups. Results Mean cement mantle thickness was 9.27 ± 1.86 mm in group 1 versus 10.49 ± 2.31 mm in group 2 (p = 0.005). Mean cumulated width of RLLs in anterioposterior (AP) view was 7.74 ± 6.68 mm in group 1 versus 3.48 ± 4.69 mm in group 2 (p < 0.001). The percentage of RLLs in AP view was related to the cumulated cement mantle thickness in the same view (r = − 0.218, p < 0.05). There was no significant difference between groups at the final follow-up in terms of ROM and new KSS. Conclusion Our results suggest that the use of tourniquet increased the cement mantle thickness under tibial implant and had an influence on the occurrence of RLLs in cement–bone interface, which is related to implant survivorship, with this implant design.Keywords
This publication has 37 references indexed in Scilit:
- Why Are Total Knees Failing Today? Etiology of Total Knee Revision in 2010 and 2011The Journal of Arthroplasty, 2013
- Why are Total Knee Arthroplasties Being Revised?The Journal of Arthroplasty, 2013
- Tourniquet use in total knee replacement does not improve fixation, but appears to reduce final range of motionActa Orthopaedica, 2012
- A Comparison of Outcomes With and Without a Tourniquet in Total Knee ArthroplastyThe Journal of Arthroplasty, 2012
- The New Knee Society Knee Scoring SystemClinical Orthopaedics and Related Research, 2012
- Tourniquet use in total knee arthroplasty: a meta‐analysisKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- Tibial Component Fixation With CementClinical Orthopaedics and Related Research, 2003
- Changes in bone mineral density at the proximal tibia after total knee arthroplasty: A 2‐year follow‐up of 28 knees using dual energy x‐ray absorptiometryJournal of Orthopaedic Research, 2000
- Long-term Results after Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1987
- Radiological Assessment of Osteo-ArthrosisAnnals of the Rheumatic Diseases, 1957