PTPanagiotis Touzopoulos

Panagiotis Touzopoulos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Panagiotis Touzopoulos has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Athanasios Ververidis

    Department of Orthopaedics, Medical School, Democritus University of Thrace, Alexandroupolis, Greece

    3 shared publications
  • Georgios I. Drosos

    Department of Orthopaedics, Faculty of Medicine, Democritus University of Thrace, University General Hospital of Alexandroupolis, Alexandroupolis, Greece

    2 shared publications
  • Athanasios Chatzigiannakis

    Department of Orthopaedics, University General Hospital of Alexandroupoli, Dragana, 68100, Alexandroupoli, Greece

    1 shared publication
  • Athanasios Ververidis

    Orthopaedic Department, Medical School, University General Hospital of Alexandroupolis, Democritus University of Thrace, St. Niarhos 1, Dragana, 68100, Alexandroupolis, Greece

    1 shared publication
  • Christos Mpogiatzis

    Department of Orthopaedics, University General Hospital of Alexandroupoli, Dragana, 68100, Alexandroupoli, Greece

    1 shared publication
  • Eirini Filidou

    Laboratory of Pharmacology, Faculty of Medicine, Democritus University of Thrace, 68100 Alexandroupolis, Greece

    1 shared publication

Latest Publications

  • Is serum gentamicin concentration modified with autologous cell-saved blood transfusion after total knee arthroplasty using tranexamic acid? A randomised control trial

    by Panagiotis Touzopoulos, Konstantinos Arvanitidis, Eirini Filidou, Konstantinos Tilkeridis, Michael Karanikas, George Kolios, Athanasios Ververidis


  • Asymmetrical thigh creases or isolated thigh crease may be a false positive sign with low predictive value in the diagnosis of developmental dysplasia of the hip in infants: a prospective cohort study of 117 patients

    by Panagiotis Touzopoulos, Nikolaos G. Markeas

    Background The clinical importance of asymmetrical thigh creases in the diagnosis of developmental dysplasia of the hip (DDH) in infants remains controversial. The aim of this study is to investigate the association of asymmetrical skinfolds of the thigh as the only clinical finding with the DDH in infants. Methods One hundred and thirty-four infants between January 2010 and December 2015 were referred to our clinics for DDH with the only clinical sign being asymmetrical or isolated thigh creases and met the inclusion criteria of the study. Patients with another clinical sign for DDH in our initial evaluation, those infants suspicious for syndrome and those older than 6 months were excluded. Finally, 117 patients had undergone clinical and ultrasound evaluation and were included to statistical analysis. Results There were 82 females and 35 males, with mean age of 2.2 months old. In 96 of the 117 infants (82.1%), there were provocative skin creases in the opposite thigh after a little pressure of the thigh by the examiner during the evaluation. Three of the babies (3.1%) with provocative skin creases and 1 (4.8%) with true isolated thigh crease had immature hips in ultrasonography. Positive predictive value for DDH of an isolated or asymmetrical thigh crease was 4.55% (95% CI 0.83–21.36%), and negative predictive value was 96.97% (95% CI 94.75–98.27%). Sensitivity of skinfold asymmetry found to be 25% (95% CI 0.63–80.59%), and specificity was 82.05% (95% CI 73.88–88.53%) for DDH. Conclusion The positive predictive value of asymmetrical or isolated thigh creases for DDH in infants was found to be low, as the majority of hips with normal clinical examination and asymmetry in thigh skinfolds seemed to be normal. Moreover, in-depth evaluation of the patients could highlight new provocative thigh creases in the opposite thigh, which could limit the referrals to expert physicians to exclude DDH. Level of evidence Level III.


  • Validation and cross-cultural adaptation of Greek version of Achilles tendon Total Rupture Score

    by Panagiotis Touzopoulos, Athanasios Ververidis, Giannis Giakas, Georgios I. Drosos


  • The use of tourniquet may influence the cement mantle thickness under the tibial implant during total knee arthroplasty

    by Panagiotis Touzopoulos, Athanasios Ververidis, Christos Mpogiatzis, Athanasios Chatzigiannakis, Georgios I. Drosos

    Introduction It is still unknown whether the creation of blood-free surfaces by the use of tourniquet during total knee arthroplasty (TKA) has an influence on cement penetration and on implant fixation. The aim of this study is to evaluate the cement mantle under tibial component and the occurrence of progressive radiolucent lines (RLLs) according to the use of tourniquet in primary TKA. Materials and methods Fifty patients undergone TKA without the use of tourniquet (group 1) were well matched regarding baseline characteristics with 50 TKAs with the use of tourniquet (group 2). Patients were followed up prospectively. Cement mantle thickness was measured using immediate postoperative X-rays, and the occurrence of progressive radiolucency was finally evaluated in 3-year follow-up. New Knee Society Score (KSS) was used to compare clinical outcome between groups. Results Mean cement mantle thickness was 9.27 ± 1.86 mm in group 1 versus 10.49 ± 2.31 mm in group 2 (p = 0.005). Mean cumulated width of RLLs in anterioposterior (AP) view was 7.74 ± 6.68 mm in group 1 versus 3.48 ± 4.69 mm in group 2 (p < 0.001). The percentage of RLLs in AP view was related to the cumulated cement mantle thickness in the same view (r = − 0.218, p < 0.05). There was no significant difference between groups at the final follow-up in terms of ROM and new KSS. Conclusion Our results suggest that the use of tourniquet increased the cement mantle thickness under tibial implant and had an influence on the occurrence of RLLs in cement–bone interface, which is related to implant survivorship, with this implant design.


  • Short stems in total hip replacement: evidence on primary stability according to the stem type

    by Georgios I Drosos, Panagiotis Touzopoulos

    As the prevalence of total hip replacement is increasing in younger patients, less invasive implants (short stems) are becoming more favourable. However, despite the advantages of these stems, clinical results with a follow-up of more than 10 years are limited to a very few stem designs. There has been an increase in publications recently – mechanical and clinical studies – concerning the primary stability of short stems. Primary stem stability is an important factor as it reflects final stem stabilisation and is related to the clinical results of the prosthesis. We conducted a systematic review of the literature to retrieve evidence concerning primary implant stability in short stems – as expressed by implant micromotion and stem subsidence – according to our previously proposed short-stem classification. Mechanical in vitro studies on stem micromotion are very few and limited to type 2 “partial collum” short stems. The results are comparable to those of stems with a known long-term excellent clinical course. Clinical results concerning stem migration patterns are also limited to some of the commercially available short stems. Although comparative studies are very few, the results for most of the short stems are similar to those of standard stems. There are promising results concerning biomechanical studies of the initial micromotion of short stems, as well as clinical results of stem migration patterns. Long-term clinical studies are needed in order to confirm these findings. The existing literature concerns very few of the many commercially available implants.


    • 1 May 2015
      • Vol. 26, 307-16

    Constrained Implants in Total Knee Replacement.

    by Panagiotis Touzopoulos, Georgios I Drosos, Athanasios Ververidis, Konstantinos Kazakos

    Total knee replacement (TKR) is a successful procedure for pain relief and functional restoration in patients with advanced osteoarthritis. The number of TKRs is increasing, and this has led to an increase in revision surgeries. The key to long-term success in both primary and revision TKR is stability, as well as adequate and stable fixation between components and underlying bone. In the vast majority of primary TKRs and in some revision cases, a posterior cruciate retaining or a posterior cruciate substituting device can be used. In some primary cases with severe deformity or ligamentous instability and in most of the revision cases, a more constrained implant is required. The purpose of this paper is to review the literature concerning the use of condylar constrained knee (CCK) and rotating hinge (RH) implants in primary and revision cases focusing on the indications and results. According to this review, although excellent and very good results have been reported, there are limitations of the existing literature concerning the indications for the use of constrained implants, the absence of long-term results, and the limited comparative studies.