Abstract
Contemporary left ventricular assist devices (LVADs) have improved survival and quality of life in patients with advanced heart failure. However, to reap these benefits our patients accept the important tradeoffs associated with this therapy; namely, bleeding, infection, neurologic events, and pump malfunction or failure.1 Although it has become customary to consider these adverse events or other negative clinical outcomes in the context of rigorously conducted clinical trials, it is equally important to acknowledge the key milestones that have decorated the evolution of this therapy. Mechanically assisted circulation has evolved dramatically over the past half-century. From the original large nondischargeable extracorporeal systems used for temporary circulatory support to the contemporary miniaturized, implantable, and durable pumps, we have witnessed a truly remarkable feat of iterative design and engineering that has afforded incremental improvement in our patients’ lives.2 In the last 2 decades, we have seen the transition from pulsatile devices to continuous flow pumps and more recently the design shift from the axial flow HeartMate II (Abbott, Abbott Park, IL) to centrifugal pumps such as the HeartMate 3 (Abbott, Abbott Park, IL) and the HeartWare HVAD (Medtronic, Framingham, MA). What’s more, the recent advances in magnetic levitation and artificial pulsatility have added another layer of improvements geared towards addressing adverse events and device reliability. At each step, newer devices have been tested meticulously against older generations in randomized controlled trials providing a strong evidence base for the clinical benefits of adopting newer technologies. In this issue of the ASAIO Journal, Mahr et al.3 present a cross-trial comparison of neurologic outcomes between the HeartWare HVAD and the HeartMate 3. Although these two contemporary centrifugal pumps have never been tested head to head in a randomized controlled setting, each has been tested against the HeartMate II. In the ENDURANCE trial, HVAD was found to be noninferior to HeartMate II in terms of survival free of disabling stroke or reoperation at 2 years in a destination therapy population but was associated with significantly more stroke (29.7% vs. 12.1%; p < 0.001).4 A retrospective analysis revealed that elevated blood pressure was an independent risk factor for stroke in the HVAD population.5 As a result, the ENDURANCE Supplemental study was conducted to assess the effect of blood pressure control on the incidence of stroke among HVAD recipients. Despite successful lowering of mean arterial pressure, the difference in neurologic events which included strokes with a modified Rankin score > 0 and transient ischemic attacks failed to reach prespecified noninferiority margins compared with a HeartMate II control group.6 However, the ENDURANCE Supplemental cohort experienced less overall stroke (16.9% vs. 22.3%; p = 0.10) and less hemorrhagic stroke (5.2% vs. 10.5%; p = 0.02) than subjects in the primary trial. The MOMENTUM 3 trial that included patients who were considered for both bridge to transplant and destination therapy indications demonstrated that HeartMate 3 was associated with improved survival free of disabling stroke or reoperation at 2 years compared with the HeartMate II (79.5% vs. 60.2%; hazard ratio (HR), 0.46; p < 0.001) and importantly, also with a lower stroke risk (10.1% vs. 19.2%; HR, 0.47; p = 0.02).7 Taken together, these data are provocative and beg the question of how neurologic outcomes differ between the HeartMate 3 and HVAD devices. However, direct comparison between these two trials is hindered by key differences in study population, endpoint definition, reporting methodology, and possible differences in medical management during the trials.

This publication has 8 references indexed in Scilit: