JRJoseph G. Rogers

Joseph G. Rogers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joseph G. Rogers has a total of 190 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Adverse Events on Functional Capacity and Quality of Life After HeartWare Ventricular Assist Device Implantation

    by Marc D. Samsky, Carmelo A. Milano, Salpy Pamboukian, Mark S. Slaughter, Emma Birks, Steven Boyce, Samer S. Najjar, Akinobu Itoh, Bruce Reid, Nahush Mokadam, et al.

    Left ventricular assist devices (LVADs) improve quality of life (QoL) and functional capacity (FC) for patients with advanced heart failure. The association between adverse events (AEs) and changes in QoL and FC are unknown. Patients treated with the HeartWare ventricular assist device (HVAD) with paired 6-minute walk distance (6MWD, n = 263) and Kansas City Cardiomyopathy Questionnaires (KCCQ, n = 272) at baseline and 24 months in the ENDURANCE and ENDURANCE Supplemental Trial databases were included. Patients were stratified based upon occurrence of clinically significant AEs during the first 24 months of support and analyzed for the mean change in 6MWD and KCCQ. The impact of AE frequency on change in 6MWD and KCCQ from baseline to 24 months was evaluated. Of the AEs examined, only sepsis was associated with an improvement in 6MWD (109 m vs. 16 m, p = 0.002). Patients without improvement in 6MWD test from baseline to 24 months had significantly more AEs than those with FC improvement (p = 0.0002). Adverse events did not affect the KCCQ overall summary score. In this analysis, patients with fewer AEs had greater improvement in FC during the 24-month follow up. The frequency of AEs did not have a significant impact on QoL after LVAD implantation.


  • Top Cited Papers

    Advanced Heart Failure

    by Lauren K. Truby, Joseph G. Rogers


  • Clinical and regulatory landscape for cardiogenic shock: A report from the Cardiac Safety Research Consortium ThinkTank on cardiogenic shock

    by Marc Samsky, Mitchell Krucoff, Andrew D. Althouse, William T. Abraham, Philip Adamson, Fernando Aguel, Seth Bilazarian, George D. Dangas, Ian C Gilchrist, Timothy D. Henry, et al.


  • RAAS Inhibition to Prevent GI Bleeding

    by Joseph G. Rogers, Adam D. DeVore

  • Different Strokes for Different Folks

    by Sounok Sen, Joseph G. Rogers

    Contemporary left ventricular assist devices (LVADs) have improved survival and quality of life in patients with advanced heart failure. However, to reap these benefits our patients accept the important tradeoffs associated with this therapy; namely, bleeding, infection, neurologic events, and pump malfunction or failure.1 Although it has become customary to consider these adverse events or other negative clinical outcomes in the context of rigorously conducted clinical trials, it is equally important to acknowledge the key milestones that have decorated the evolution of this therapy. Mechanically assisted circulation has evolved dramatically over the past half-century. From the original large nondischargeable extracorporeal systems used for temporary circulatory support to the contemporary miniaturized, implantable, and durable pumps, we have witnessed a truly remarkable feat of iterative design and engineering that has afforded incremental improvement in our patients’ lives.2 In the last 2 decades, we have seen the transition from pulsatile devices to continuous flow pumps and more recently the design shift from the axial flow HeartMate II (Abbott, Abbott Park, IL) to centrifugal pumps such as the HeartMate 3 (Abbott, Abbott Park, IL) and the HeartWare HVAD (Medtronic, Framingham, MA). What’s more, the recent advances in magnetic levitation and artificial pulsatility have added another layer of improvements geared towards addressing adverse events and device reliability. At each step, newer devices have been tested meticulously against older generations in randomized controlled trials providing a strong evidence base for the clinical benefits of adopting newer technologies. In this issue of the ASAIO Journal, Mahr et al.3 present a cross-trial comparison of neurologic outcomes between the HeartWare HVAD and the HeartMate 3. Although these two contemporary centrifugal pumps have never been tested head to head in a randomized controlled setting, each has been tested against the HeartMate II. In the ENDURANCE trial, HVAD was found to be noninferior to HeartMate II in terms of survival free of disabling stroke or reoperation at 2 years in a destination therapy population but was associated with significantly more stroke (29.7% vs. 12.1%; p < 0.001).4 A retrospective analysis revealed that elevated blood pressure was an independent risk factor for stroke in the HVAD population.5 As a result, the ENDURANCE Supplemental study was conducted to assess the effect of blood pressure control on the incidence of stroke among HVAD recipients. Despite successful lowering of mean arterial pressure, the difference in neurologic events which included strokes with a modified Rankin score > 0 and transient ischemic attacks failed to reach prespecified noninferiority margins compared with a HeartMate II control group.6 However, the ENDURANCE Supplemental cohort experienced less overall stroke (16.9% vs. 22.3%; p = 0.10) and less hemorrhagic stroke (5.2% vs. 10.5%; p = 0.02) than subjects in the primary trial. The MOMENTUM 3 trial that included patients who were considered for both bridge to transplant and destination therapy indications demonstrated that HeartMate 3 was associated with improved survival free of disabling stroke or reoperation at 2 years compared with the HeartMate II (79.5% vs. 60.2%; hazard ratio (HR), 0.46; p < 0.001) and importantly, also with a lower stroke risk (10.1% vs. 19.2%; HR, 0.47; p = 0.02).7 Taken together, these data are provocative and beg the question of how neurologic outcomes differ between the HeartMate 3 and HVAD devices. However, direct comparison between these two trials is hindered by key differences in study population, endpoint definition, reporting methodology, and possible differences in medical management during the trials.

  • It Is Time to Discuss Dying

    by Haider J. Warraich, Joseph G. Rogers


  • When VAD Things Happen to Good People

    by Marc D. Samsky, Joseph G. Rogers

    In his book, When Bad Things Happen to Good People, Harold Kushner explores explanations for human pain and suffering. He notes that while many of the afflictions of the human condition are beyond our understanding, none of us are exempt from the common experience. Despite the original publication of this thesis more than 35 years ago, Kushner's musings draw parallels to the patient experience with mechanically assisted circulation. The underlying mechanism and management of several morbid and mortal left ventricular assist device (LVAD) complications are beyond contemporary understanding but are sufficiently frequent to be considered common. The paper by Soliman in this issue of Circulation adds clarity to the question about why VAD things happen to good people by defining pre-operative risk factors that predispose patients to the development of right heart failure following implantation of a left-sided mechanical blood pump.