Comparison of ITS-90 realizations from 13 K to 273 K between LNE-CNAM and INRIM
Authors:
- Dario ImbraguglioDIDario Imbraguglio
- Petrus Paulus Maria SteurPSPetrus Paulus Maria Steur
Preprint
Abstract
Since Key Comparison CCT-K2, only few comparisons on realizations of cryogenic fixed points have been carried out, be they bilateral (three, of which one still pending) or multilateral (two trilateral). Since a forthcoming general follow-up is unlikely, any bilateral comparison, not only key comparisons, is most welcome to provide evidence of the continuing thermometric capabilities of the laboratories involved in the realization of the ITS-90. Not too long after the creation in 2018 of the Joint Research Laboratory for Fluid Metrology Evangelista Torricelli between LNE-CNAM and INRIM, the two laboratories agreed to perform a bilateral comparison at all the cryogenic fixed points of the scale between 13 K and 273 K, including the two hydrogen vapour-pressure temperatures required for the full platinum resistance thermometer range 3.3.1 of the ITS-90. The results are reported here and show a substantial agreement, within the combined uncertainties.Keywords
All Related Versions
- Version 1, 2020-07-22, ArXiv
- Version 2, 2020-08-04, ArXiv
- Published version: Measurement, 166.
This publication has 16 references indexed in Scilit:
- Dependence of the triple point temperature of neon on isotopic composition and its implications for the ITS-90AIP Conference Proceedings, 2013
- Adjustments to the ICVGT scale of INRIMAIP Conference Proceedings, 2013
- A new calorimeter for the simultaneous calibration of SPRTs and CSPRTs at the triple point of mercuryAIP Conference Proceedings, 2013
- An Adiabatic Calorimeter for the Realization of the ITS-90 in the Cryogenic Range at the LNE-CNAMInternational Journal of Thermophysics, 2011
- CCT-K2.1: NRC/VNIIFTRI bilateral comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 KMetrologia, 2005
- Cryogenic Temperature Sealed Fixed Points: a New-Generation of Modular Cells at IMGCAIP Conference Proceedings, 2003
- “MULTICELLS”: A European Project on Cryogenic Temperature Fixed Points in Sealed CellsAIP Conference Proceedings, 2003
- The IMGC Interpolating Constant Volume Gas Thermometer — New DataAIP Conference Proceedings, 2003
- CCT-K2: key comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 KMetrologia, 2002
- Confidence-interval interpretation of a measurement pair for quantifying a comparisonMetrologia, 1998