Dario Imbraguglio has a total of 90 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dissemination of thermodynamic temperature by gas thermometry below 300 K

    by Roberto Maria Gavioso, Peter Steur, Giuseppina Lopardo, Dario Imbraguglio

    The redefinition of the kelvin motivates the realization of thermodynamic temperature standards and their improvement up to the stage where they become sufficiently accurate, reliable and practically useful for the purpose of disseminating the unit by direct calibration of temperature sensors. We review progress milestones in the development of gas-based primary thermometry methods, assess their current state of the art and discuss the remaining challenges and the perspectives of using thermodynamic methods as an alternative to traditional dissemination based on the realization of the International Temperature Scale. We give an account of research initiatives which are underway to test the maturity of this perspective, including an international blind comparison of thermodynamic calibrations of capsule-type resistance thermometers using different methods of primary gas thermometry in the range 4 to 300 K. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.


  • Open Access

    Direct calibration of resistance thermometers between 10 K and 25 K by absolute acoustic gas thermometry in helium

    by Dario Imbraguglio, Peter P. M. Steur, Roberto M. Gavioso

    We have implemented absolute acoustic gas thermometry at 10 K, 13.8 K, 19 K and 24.6 K to evaluate the performance of this primary method for the direct thermodynamic calibration of capsule-type resistance thermometers, including both platinum and rhodium-iron types. Our implementation is based on speed of sound measurements in helium at a single pressure, chosen in the range 65 to 130 kPa, with non-ideality corrections relying on accurate ab initio calculations of the thermodynamic properties. The overall accuracy achieved in the determination of the thermodynamic temperature T varies between a minimum of 0.1 mK at 13.8 K to a maximum of 0.2 mK at 24.6 K. From the acoustic results and the calibration of thermometers on the international temperature scale ITS-90 providing T90, we determined the differences (T−T90), finding them in good agreement with the 2022 consensus estimates within the combined uncertainties. These results include a determination of the thermodynamic temperature at the triple point of neon TNe = (24.55502 ± 0.00030) K. This new value of TNe is consistent with other recent determinations obtained with various primary methods. Finally, we provide an example of a rapid, yet accurate, simplified thermodynamic calibration procedure. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.


  • Open Access

    European Partnership in Metrology Project: Photonic and Quantum Sensors for Practical Integrated Primary Thermometry (PhoQuS-T)

    by Olga Kozlova, Rémy Braive, Tristan Briant, Stéphan Briaudeau, Paulina Castro Rodríguez, Guochun Du, Tufan Erdoğan, René Eisermann, Emile Ferreux, Dario Imbraguglio, et al.

    Current temperature sensors require regular recalibration to maintain reliable temperature measurement. Photonic/quantum-based approaches have the potential to radically change the practice of thermometry through provision of in situ traceability, potentially through practical primary thermometry, without the need for sensor recalibration. This article gives an overview of the European Partnership in Metrology (EPM) project: Photonic and quantum sensors for practical integrated primary thermometry (PhoQuS-T), which aims to develop sensors based on photonic ring resonators and optomechanical resonators for robust, small-scale, integrated, and wide-range temperature measurement. The different phases of the project will be presented. The development of the integrated optical practical primary thermometer operating from 4 K to 500 K will be reached by a combination of different sensing techniques: with the optomechanical sensor, quantum thermometry below 10 K will provide a quantum reference for the optical noise thermometry (operating in the range 4 K to 300 K), whilst using the high-resolution photonic (ring resonator) sensor the temperature range to be extended from 80 K to 500 K. The important issues of robust fibre-to-chip coupling will be addressed, and application case studies of the developed sensors in ion-trap monitoring and quantum-based pressure standards will be discussed.


  • From ITS-90 to thermodynamic temperature: Hybrid CSPRT calibrations with LNE-Cnam acoustic gas thermometry

    by D. Imbraguglio, C. Pan, F. Sparasci, R. M. Gavioso, D. Madonna Ripa, P. M. C. Rourke, H. Zhang, B. Gao, L. Pitre

    In the cryogenic temperature range between 13.8033 K and 273.16 K, eight fixed points are required by the International Temperature Scale of 1990 (ITS-90 or T90 In the cryogenic temperature range between 13.8033 K and 273.16 K, eight fixed points are required by the International Temperature Scale of 1990 (ITS-90 or T90


  • Open Access

    Corrigendum: Refractive index gas thermometry between 13.8 K and 161.4 K (2021 Metrologia 58 025008)

    by D Madonna Ripa, D Imbraguglio, C Gaiser, P P M Steur, D Giraudi, M Fogliati, M Bertinetti, G Lopardo, R Dematteis, R M Gavioso


  • Open Access

    Acoustic measurement of the triple point of neon T Ne and thermodynamic calibration of a transfer standard for accurate cryogenic thermometry

    by Changzhao Pan, Fernando Sparasci, Haiyang Zhang, Pascal Gambette, Mark Plimmer, Dario Imbraguglio, Roberto M Gavioso, Michael R Moldover, Bo Gao, Laurent Pitre

    We used absolute primary acoustic gas thermometry (AGT) to calibrate a Pt–Co resistance thermometer on the thermodynamic temperature scale by measuring the speed of sound in helium at a temperature T* chosen to be near the temperature of the triple point of neon, T Ne. Prior to the present AGT, the Pt–Co thermometer was used with a neon triple-point cell as part of an interlaboratory comparison. Taken together, the results of the interlaboratory comparison and the present AGT redetermined the thermodynamic temperature T Ne = (24.555 15 ± 0.000 24) K. This new value of T Ne is consistent with other recent determinations obtained with various primary methods. After completing the AGT thermodynamic calibration, we used the Pt–Co thermometer to link T* to the temperature ratios measured by single-pressure refractive-index gas thermometry (SPRIGT) in a different laboratory. (Gao et al 2020 Metrologia 57 065006) Now, the T*-linked SPRIGT system can calibrate other thermometers on the thermodynamic temperature scale T in the range 5 K ⩽ T ⩽ T Ne without using the international temperature scale ITS-90. At most temperatures in this range, the uncertainties of the T*-linked SPRIGT system are smaller than those of the ITS-90 systems used by National Metrology Institutes to calibrate resistance thermometers.


  • Open Access

    Refractive index gas thermometry between 13.8 K and 161.4 K

    by Daniele Madonna Ripa, Dario Imbraguglio, Christof Gaiser, Peter P M Steur, Domenico Giraudi, Martina Fogliati, Marco Bertinetti, Giuseppina Lopardo, Roberto Dematteis, Roberto Maria Maria Gavioso

    We have measured the refractive index of helium using a quasi-spherical copper microwave resonator at five different temperatures in the interval between the triple point of hydrogen at 13.8 K and the triple point of xenon at 161.4 K for pressures up to 380 kPa. From these results and additional measurements of the refractive index of neon near 54.4 K, 83.8 K and 161.4 K we determine the differences (T − T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). We have estimated the isothermal compressibility of copper and the effective compressibility of our microwave resonator by different methods including resonant ultrasound spectroscopy (RUS) and microwave measurements with helium at 273.16 K. We compare the results of these compressibility estimates and discuss the associated uncertainty. From the refractive index measurements, we estimate the second density virial coefficient of helium and neon which are found in good agreement with the ab initio calculations of the same properties.


  • Open Access

    Comparison of ITS-90 realizations from 13 K to 273 K between LNE-CNAM and INRIM

    by Dario Imbraguglio, Petrus Paulus Maria Steur, Fernando Sparasci

    Since Key Comparison CCT-K2, only few comparisons on realizations of cryogenic fixed points have been carried out, be they bilateral (three, of which one still pending) or multilateral (two trilateral). Since a forthcoming general follow-up is unlikely, any bilateral comparison, not only key comparisons, is most welcome to provide evidence of the continuing thermometric capabilities of the laboratories involved in the realization of the ITS-90. Not too long after the creation in 2018 of the Joint Research Laboratory for Fluid Metrology Evangelista Torricelli between LNE-CNAM and INRIM, the two laboratories agreed to perform a bilateral comparison at all the cryogenic fixed points of the scale between 13 K and 273 K, including the two hydrogen vapour-pressure temperatures required for the full platinum resistance thermometer range 3.3.1 of the ITS-90. The results are reported here and show a substantial agreement, within the combined uncertainties.

  • Open Access

    Determination of the thermodynamic temperature between 236 K and 430 K from speed of sound measurements in helium

    by Roberto Maria Gavioso, Daniele Madonna Ripa, Peter P M Steur, Roberto Dematteis, Dario Imbraguglio

    We report speed of sound measurements in helium at 273.16 K and at eight temperatures in the range between 236 K and 430 K. These results determine the difference (T − T 90) between the thermodynamic temperature T and its approximation T 90 by the International Temperature Scale of 1990 (ITS-90). The uncertainty of our measurements of (T − T 90) spans between a minimum of 0.25 mK near 247 K and a maximum of 0.89 mK at the freezing point of indium (429.75 K) with comparable contributions from the uncertainty of our acoustic determination of T and from the uncertainty of our laboratory realization of ITS-90. On the overlapping temperature ranges these results are consistent with other recent acoustic determinations of (T − T 90). We also present evidence that (T − T 90) can be determined with comparably small uncertainties by the alternative, time-saving procedure of measuring the speed-of-sound in helium using only a single, judiciously-chosen, pressure on each isotherm.


  • Open Access

    Extending the plasmonic lifetime of tip-enhanced Raman spectroscopy probes

    by Naresh Kumar, Steve J. Spencer, Dario Imbraguglio, Andrea M. Rossi, Andrew J. Wain, Bert M. Weckhuysen, Debdulal Roy

    Relationship between plasmonic lifetime of tip-enhanced Raman spectroscopy probes and environments with different oxygen and moisture content is investigated systematically.