Reliable detection of generalized convulsive seizures using an off‐the‐shelf digital watch: A multisite phase 2 study
Abstract
Objective: The aim of this study was to develop a machine learning algorithm using an off‐the‐shelf digital watch, the Samsung watch (SM‐R800), and evaluate its effectiveness for the detection of generalized convulsive seizures (GCS) in persons with epilepsy.Methods: This multisite epilepsy monitoring unit (EMU) phase 2 study included 36 adult patients. Each patient wore a Samsung watch that contained accelerometer, gyroscope, and photoplethysmographic sensors. Sixty‐eight time and frequency domain features were extracted from the sensor data and were used to train a random forest algorithm. A testing framework was developed that would better reflect the EMU setting, consisting of (1) leave‐one‐patient‐out cross‐validation (LOPO CV) on GCS patients, (2) false alarm rate (FAR) testing on nonseizure patients, and (3) “fixed‐and‐frozen” prospective testing on a prospective patient cohort. Balanced accuracy, precision, sensitivity, and FAR were used to quantify the performance of the algorithm. Seizure onsets and offsets were determined by using video‐electroencephalographic (EEG) monitoring. Feature importance was calculated as the mean decrease in Gini impurity during the LOPO CV testing.Results: LOPO CV results showed balanced accuracy of .93 (95% confidence interval [CI] = .8–.98), precision of .68 (95% CI = .46–.85), sensitivity of .87 (95% CI = .62–.96), and FAR of .21/24 h (interquartile range [IQR] = 0–.90). Testing the algorithm on patients without seizure resulted in an FAR of .28/24 h (IQR = 0–.61). During the “fixed‐and‐frozen” prospective testing, two patients had three GCS, which were detected by the algorithm, while generating an FAR of .25/24 h (IQR = 0–.89). Feature importance showed that heart rate‐based features outperformed accelerometer/gyroscope‐based features.Significance: Commercially available wearable digital watches that reliably detect GCS, with minimum false alarm rates, may overcome usage adoption and other limitations of custom‐built devices. Contingent on the outcomes of a prospective phase 3 study, such devices have the potential to provide non‐EEG‐based seizure surveillance and forecasting in the clinical setting.Keywords
Funding Information
- Foundation for the National Institutes of Health (R01NS126690)
This publication has 32 references indexed in Scilit:
- Novel electrode architecture for subgaleal electroencephalography: a feasibility studySensors & Diagnostics, 2021
- Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical NeurophysiologyClinical Neurophysiology, 2021
- Tonic-clonic seizure detection using accelerometry-based wearable sensors: A prospective, video-EEG controlled studySeizure: European Journal of Epilepsy, 2019
- Onset Detection of Epileptic Seizures From Accelerometry Signal2018
- Multimodal, automated detection of nocturnal motor seizures at home: Is a reliable seizure detector feasible?Epilepsia Open, 2017
- Tracking generalized tonic-clonic seizures with a wrist accelerometer linked to an online databaseSeizure: European Journal of Epilepsy, 2016
- SmartWatch by SmartMonitor: Assessment of Seizure Detection Efficacy for Various Seizure Types in Children, a Large Prospective Single-Center StudyPediatric Neurology, 2015
- Detection of seizure-like movements using a wrist accelerometerEpilepsy & Behavior, 2011
- A Novel Portable Seizure Detection Alarm System: Preliminary ResultsJournal Of Clinical Neurophysiology, 2011
- Random ForestsMachine Learning, 2001