Efficacy of magnetic resonance imaging at 3 T compared with 1.5 T in small pituitary tumors for stereotactic radiosurgery planning
Authors:
- 19 November 2013
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (1) , 22-29
Abstract
The objective of this study was to determine the value of high-field magnetic resonance imaging and to clarify the characteristics of each image among three-dimensional gradient echo (3D-GRE), two-dimensional spin echo (2D-SE) and inversion recovery (2D-IR) sequences used as contrast-enhanced T1-weighted images for stereotactic irradiation treatment planning of sellar lesions. Pulse sequences of 2D-SE and 3D-spoiled gradient recalled acquisition in the steady state (3D-SPGR) using GRE at 1.5 T and 2D-IR and 3D-fast SPGR (3D-FSPGR) at 3 T after injection of contrast material were acquired for 14 small pituitary tumors. As quantitative methods, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated using a region-of-interest analysis. There was no significant difference in SNR between 1.5-T SPGR and 3-T FSPGR, while 3-T IR was superior to 1.5-T SE. The 2D-SE and -IR provided significantly better CNR than 3D-GRE between tumor and normal structures. Three Tesla was found to be superior to 1.5 T in distinguishing tumors from the normal sellar structure. Optimal dose planning will utilize each advantage of imaging; 3D-GRE allows high-resolution acquisition and 2D-SE and -IR can offer better tissue contrast.Keywords
This publication has 18 references indexed in Scilit:
- Three-dimensional gradient echo versus spin echo sequence in contrast-enhanced imaging of the pituitary gland at 3TEuropean Journal of Radiology, 2011
- Initial experience of 3 Tesla versus conventional field strength magnetic resonance imaging of small functioning pituitary tumoursClinical Endocrinology, 2011
- Clinical Evaluation of Stereotactic Target Localization Using 3-Tesla MRI for Radiosurgery PlanningInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Stereotactic Imaging for Radiosurgery: Localization Accuracy of Magnetic Resonance Imaging and Positron Emission Tomography Compared with Computed TomographyStereotactic and Functional Neurosurgery, 2006
- Early experience with Matrix detachable coilsJournal of Neurosurgery, 2006
- The value of high-field MRI (3T) in the assessment of sellar lesionsEuropean Journal of Radiology, 2005
- Application of three-tesla magnetic resonance imaging for diagnosis and surgery of sellar lesionsJournal of Neurosurgery, 2004
- FID-Acquired-Echos (FAcE): A short echo time imaging method for flow artefact suppressionMagnetic Resonance Imaging, 1991
- MR imaging of cavernous sinus involvement by pituitary adenomasAmerican Journal of Roentgenology, 1988
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986