Hisato Nakazawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hisato Nakazawa has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Takahiko Tsugawa
Nagoya Radiosurgery Center Nagoya Kyoritsu Hospital Nagoya Aichi Japan
9 shared publicationsYuta Shibamoto
Department of Radiology Nagoya City University Graduate School of Medical Sciences Nagoya Aichi Japan
9 shared publicationsMasataka Komori
Department of Radiological Sciences Nagoya University Graduate School of Medicine Nagoya Aichi Japan
8 shared publicationsTatsuya Kobayashi
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital
8 shared publicationsYoshimasa Mori
Department of Radiology and Radiation Oncology Aichi Medical University Nagakute Aichi Japan
8 shared publicationsChisa Hashizume
Nagoya Radiosurgery Center, Nagoya Kyoritsu Hospital, Nagoya, Japan
6 shared publications
Latest Publications
- 15 August 2014
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 58 (5) , 595-600
Geometric accuracy in three‐dimensional coordinates of Leksell stereotactic skull frame with wide‐bore 1.5‐T MRI compared with conventional 1.5‐T MRI
Summary: The use of 1.5‐tesla (T) magnetic resonance (MR) imaging with a wide and simultaneously short bore enhances patient comfort compared with traditional 1.5‐T MR imaging and is becoming increasingly available in stereotactic radiosurgery treatment planning. However, the geometric accuracy seems unavoidably worse in wide‐bore MR imaging than in conventional MR imaging. We assessed the geometric distortion of the stereotactic image attached on a Leksell skull frame in conventional and wide‐bore 1.5‐T MR imaging. Two kinds of acrylic phantoms were placed on the skull frame and were scanned using computed tomography (CT) and conventional and wide‐bore 1.5‐T MR imaging. The three‐dimensional coordinates on both MR imaging were compared with those on CT. Deviations of measured coordinates at selected points (x = 50, 100, 150 mm; y = 50, 100, 150 mm) were indicated on different axial planes (z = 50, 75, 100, 125, 150 mm). The differences of coordinates were less than 1.0 mm in the entire treatable area for conventional MR imaging. With the large bore system, the differences of the coordinates were less than 1.0 mm around the center but substantially exceeded 1.0 mm in the peripheral regions. Further study is needed to increase the geometric accuracy of wide‐bore MR imaging for stereotactic radiosurgery treatment planning.
- 15 August 2014
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 58 (5) , 595-600
Geometric accuracy in three‐dimensional coordinates of Leksell stereotactic skull frame with wide‐bore 1.5‐T MRI compared with conventional 1.5‐T MRI
Summary: The use of 1.5‐tesla (T) magnetic resonance (MR) imaging with a wide and simultaneously short bore enhances patient comfort compared with traditional 1.5‐T MR imaging and is becoming increasingly available in stereotactic radiosurgery treatment planning. However, the geometric accuracy seems unavoidably worse in wide‐bore MR imaging than in conventional MR imaging. We assessed the geometric distortion of the stereotactic image attached on a Leksell skull frame in conventional and wide‐bore 1.5‐T MR imaging. Two kinds of acrylic phantoms were placed on the skull frame and were scanned using computed tomography (CT) and conventional and wide‐bore 1.5‐T MR imaging. The three‐dimensional coordinates on both MR imaging were compared with those on CT. Deviations of measured coordinates at selected points (x = 50, 100, 150 mm; y = 50, 100, 150 mm) were indicated on different axial planes (z = 50, 75, 100, 125, 150 mm). The differences of coordinates were less than 1.0 mm in the entire treatable area for conventional MR imaging. With the large bore system, the differences of the coordinates were less than 1.0 mm around the center but substantially exceeded 1.0 mm in the peripheral regions. Further study is needed to increase the geometric accuracy of wide‐bore MR imaging for stereotactic radiosurgery treatment planning.
- Open Access
- 17 July 2014
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (6) , 1184-1191
Geometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials
We assessed the geometric distortion of 1.5-Tesla (T) and 3.0-T magnetic resonance (MR) images with the Leksell skull frame system using three types of cranial quick fixation screws (QFSs) of different materials—aluminum, aluminum with tungsten tip, and titanium—for skull frame fixation. Two kinds of acrylic phantoms were placed on a Leksell skull frame using the three types of screws, and were scanned with computed tomography (CT), 1.5-T MR imaging and 3.0-T MR imaging. The 3D coordinates for both strengths of MR imaging were compared with those for CT. The deviations of the measured coordinates at selected points (x = 50, 100 and 150; y = 50, 100 and 150) were indicated on different axial planes (z = 50, 75, 100, 125 and 150). The errors of coordinates with QFSs of aluminum, tungsten-tipped aluminum, and titanium were 2.0 mm in most positions. The geometric accuracy of the Leksell skull frame system with 1.5-T MR imaging was high and valid for clinical use. However, the geometric errors with 3.0-T MR imaging were larger than those of 1.5-T MR imaging and were acceptable only with aluminum QFSs, and then only around the central region.
- 17 July 2014
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (6) , 1184-1191
Open AccessGeometric accuracy of 3D coordinates of the Leksell stereotactic skull frame in 1.5 Tesla- and 3.0 Tesla-magnetic resonance imaging: a comparison of three different fixation screw materials
We assessed the geometric distortion of 1.5-Tesla (T) and 3.0-T magnetic resonance (MR) images with the Leksell skull frame system using three types of cranial quick fixation screws (QFSs) of different materials—aluminum, aluminum with tungsten tip, and titanium—for skull frame fixation. Two kinds of acrylic phantoms were placed on a Leksell skull frame using the three types of screws, and were scanned with computed tomography (CT), 1.5-T MR imaging and 3.0-T MR imaging. The 3D coordinates for both strengths of MR imaging were compared with those for CT. The deviations of the measured coordinates at selected points (x = 50, 100 and 150; y = 50, 100 and 150) were indicated on different axial planes (z = 50, 75, 100, 125 and 150). The errors of coordinates with QFSs of aluminum, tungsten-tipped aluminum, and titanium were 2.0 mm in most positions. The geometric accuracy of the Leksell skull frame system with 1.5-T MR imaging was high and valid for clinical use. However, the geometric errors with 3.0-T MR imaging were larger than those of 1.5-T MR imaging and were acceptable only with aluminum QFSs, and then only around the central region.
- 16 July 2014
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 156 (10) , 1929-1935
Assessment of spatial uncertainty in computed tomography-based Gamma Knife stereotactic radiosurgery process with automated positioning system
In this study, we assessed the geometric accuracy of an automated positioning system in Gamma Knife (GK) surgery. Specifically, we looked at the total spatial uncertainty over the entire treatment range of GK stereotactic radiosurgery (SRS) procedures in both the GK model C and the Perfexion (PFX). An originally-developed phantom and a radiochromic film were used for obtaining actual dose distributions. The phantom, with inserted films on different axial planes (z = 60, 75, 100, 125, 140 mm), sagittal planes (x = 60, 75, 100, 125, 140 mm), and coronal planes (y = 60, 75, 100, 125, 140 mm), was placed on a Leksell skull frame. Computed tomography (CT) was then performed with a stereotactic localizer box attached to the frame, and dose planning was made using the Leksell GammaPlan treatment planning system. The phantom finally received beam delivery using a single shot of a 4-mm collimator helmet. The discrepancy between the planned shot position and the irradiated center position was evaluated by a dedicated film analysis software. The total uncertainty of CT-based GK SRS was less than 1 mm for almost all measured points over the stereotactic space in both the model C and the PFX. In addition, the geometric accuracy of the automated positioning system was estimated to be less than 0.1 mm and equal to 0.5 mm in the central and peripheral areas, respectively. We confirmed that the total spatial uncertainties of both the GK model C and the PFX are acceptable for clinical use.
- 16 July 2014
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 156 (10) , 1929-1935
Assessment of spatial uncertainty in computed tomography-based Gamma Knife stereotactic radiosurgery process with automated positioning system
In this study, we assessed the geometric accuracy of an automated positioning system in Gamma Knife (GK) surgery. Specifically, we looked at the total spatial uncertainty over the entire treatment range of GK stereotactic radiosurgery (SRS) procedures in both the GK model C and the Perfexion (PFX). An originally-developed phantom and a radiochromic film were used for obtaining actual dose distributions. The phantom, with inserted films on different axial planes (z = 60, 75, 100, 125, 140 mm), sagittal planes (x = 60, 75, 100, 125, 140 mm), and coronal planes (y = 60, 75, 100, 125, 140 mm), was placed on a Leksell skull frame. Computed tomography (CT) was then performed with a stereotactic localizer box attached to the frame, and dose planning was made using the Leksell GammaPlan treatment planning system. The phantom finally received beam delivery using a single shot of a 4-mm collimator helmet. The discrepancy between the planned shot position and the irradiated center position was evaluated by a dedicated film analysis software. The total uncertainty of CT-based GK SRS was less than 1 mm for almost all measured points over the stereotactic space in both the model C and the PFX. In addition, the geometric accuracy of the automated positioning system was estimated to be less than 0.1 mm and equal to 0.5 mm in the central and peripheral areas, respectively. We confirmed that the total spatial uncertainties of both the GK model C and the PFX are acceptable for clinical use.
- Open Access
- 24 June 2014
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (6) , 1192-1198
Effective usage of a clearance check to avoid a collision in Gamma Knife Perfexion radiosurgery with the Leksell skull frame
Skull frame attachment is one of the most significant issues with Gamma Knife radiosurgery. Because of the potential for suffering by patients, careful control of the frame position is required to avoid circumstances such as collision between the frame or the patient's head and the collimator helmet, and inaccessible target coordinates. This study sought to develop a simulation method to find the appropriate frame location on the patient's head by retrospective analysis of treatment plans for brain metastasis cases. To validate the accuracy of the collision warning, we compared the collision distance calculated using Leksell GammaPlan (LGP) with actual measured distances. We then investigated isocenter coordinates in near-collision cases using data from 844 previously treated patients and created a clearance map by superimposing them on CT images for just the frame, post and stereotactic fiducial box. The differences in distance between the simulation in LGP and the measured values were <1.0 mm. In 177 patients, 213 lesions and 461 isocenters, there was a warning of one possible collision. The clearance map was helpful for simulating appropriate skull frame placement. The clearance simulation eliminates the psychological stress associated with potential collisions, and enables more comfortable treatment for the patient.
- 24 June 2014
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (6) , 1192-1198
Open AccessEffective usage of a clearance check to avoid a collision in Gamma Knife Perfexion radiosurgery with the Leksell skull frame
Skull frame attachment is one of the most significant issues with Gamma Knife radiosurgery. Because of the potential for suffering by patients, careful control of the frame position is required to avoid circumstances such as collision between the frame or the patient's head and the collimator helmet, and inaccessible target coordinates. This study sought to develop a simulation method to find the appropriate frame location on the patient's head by retrospective analysis of treatment plans for brain metastasis cases. To validate the accuracy of the collision warning, we compared the collision distance calculated using Leksell GammaPlan (LGP) with actual measured distances. We then investigated isocenter coordinates in near-collision cases using data from 844 previously treated patients and created a clearance map by superimposing them on CT images for just the frame, post and stereotactic fiducial box. The differences in distance between the simulation in LGP and the measured values were <1.0 mm. In 177 patients, 213 lesions and 461 isocenters, there was a warning of one possible collision. The clearance map was helpful for simulating appropriate skull frame placement. The clearance simulation eliminates the psychological stress associated with potential collisions, and enables more comfortable treatment for the patient.
- 3 June 2014
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 156 (8) , 1483-1489
Dosimetric comparison of absolute and relative dose distributions between tissue maximum ratio and convolution algorithms for acoustic neurinoma plans in Gamma Knife radiosurgery
The treatment planning for Gamma Knife (GK) stereotactic radiosurgery (SRS) that performs dose calculations based on tissue maximum ratio (TMR) algorithm has disadvantages in predicting dose in tissue heterogeneity. The latest version of the planning software is equipped with a convolution dose algorithm as an optional extra and the new algorithm is able to compensate for head inhomogeneity. However, the effect of this improved calculation method requires detailed validation in clinical cases. In this study, we compared absolute and relative dose distributions of treatment plans for acoustic neurinoma between TMR and the convolution calculation. Twenty-nine clinically used plans created by TMR algorithm were recalculated by convolution method. Differences between TMR and convolution were evaluated in terms of absolute dose (beam-on time), dosimetric parameters including target coverage, selectivity, conformity index, gradient index, radical homogeneity index and the dose-volume relationship. The discrepancy in estimated absolute dose to the target ranged from 1 to 7 % between TMR and convolution. In addition, dosimetric parameters of the two methods achieved statistical significance. However, it was difficult to see the change of relative dose distribution by visual assessment on a monitor. Convolution, heterogeneity correction calculation, and the algorithm are necessary to reduce the dosimetric uncertainty of each case in GK SRS.
- 3 June 2014
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 156 (8) , 1483-1489
Dosimetric comparison of absolute and relative dose distributions between tissue maximum ratio and convolution algorithms for acoustic neurinoma plans in Gamma Knife radiosurgery
The treatment planning for Gamma Knife (GK) stereotactic radiosurgery (SRS) that performs dose calculations based on tissue maximum ratio (TMR) algorithm has disadvantages in predicting dose in tissue heterogeneity. The latest version of the planning software is equipped with a convolution dose algorithm as an optional extra and the new algorithm is able to compensate for head inhomogeneity. However, the effect of this improved calculation method requires detailed validation in clinical cases. In this study, we compared absolute and relative dose distributions of treatment plans for acoustic neurinoma between TMR and the convolution calculation. Twenty-nine clinically used plans created by TMR algorithm were recalculated by convolution method. Differences between TMR and convolution were evaluated in terms of absolute dose (beam-on time), dosimetric parameters including target coverage, selectivity, conformity index, gradient index, radical homogeneity index and the dose-volume relationship. The discrepancy in estimated absolute dose to the target ranged from 1 to 7 % between TMR and convolution. In addition, dosimetric parameters of the two methods achieved statistical significance. However, it was difficult to see the change of relative dose distribution by visual assessment on a monitor. Convolution, heterogeneity correction calculation, and the algorithm are necessary to reduce the dosimetric uncertainty of each case in GK SRS.
- Open Access
- 29 April 2014
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (5) , 924-933
Validation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery
The latest version of Leksell GammaPlan (LGP) is equipped with Digital Imaging and Communication in Medicine (DICOM) image-processing functions including image co-registration. Diagnostic magnetic resonance imaging (MRI) taken prior to Gamma Knife treatment is available for virtual treatment pre-planning. On the treatment day, actual dose planning is completed on stereotactic MRI or computed tomography (CT) (with a frame) after co-registration with the diagnostic MRI and in association with the virtual dose distributions. This study assesses the accuracy of image co-registration in a phantom study and evaluates its usefulness in clinical cases. Images of three kinds of phantoms and 11 patients are evaluated. In the phantom study, co-registration errors of the 3D coordinates were measured in overall stereotactic space and compared between stereotactic CT and diagnostic CT, stereotactic MRI and diagnostic MRI, stereotactic CT and diagnostic MRI, and stereotactic MRI and diagnostic MRI co-registered with stereotactic CT. In the clinical study, target contours were compared between stereotactic MRI and diagnostic MRI co-registered with stereotactic CT. The mean errors of coordinates between images were < 1 mm in all measurement areas in both the phantom and clinical patient studies. The co-registration function implemented in LGP has sufficient geometrical accuracy to assure appropriate dose planning in clinical use.
- 29 April 2014
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (5) , 924-933
Open AccessValidation of accuracy in image co-registration with computed tomography and magnetic resonance imaging in Gamma Knife radiosurgery
The latest version of Leksell GammaPlan (LGP) is equipped with Digital Imaging and Communication in Medicine (DICOM) image-processing functions including image co-registration. Diagnostic magnetic resonance imaging (MRI) taken prior to Gamma Knife treatment is available for virtual treatment pre-planning. On the treatment day, actual dose planning is completed on stereotactic MRI or computed tomography (CT) (with a frame) after co-registration with the diagnostic MRI and in association with the virtual dose distributions. This study assesses the accuracy of image co-registration in a phantom study and evaluates its usefulness in clinical cases. Images of three kinds of phantoms and 11 patients are evaluated. In the phantom study, co-registration errors of the 3D coordinates were measured in overall stereotactic space and compared between stereotactic CT and diagnostic CT, stereotactic MRI and diagnostic MRI, stereotactic CT and diagnostic MRI, and stereotactic MRI and diagnostic MRI co-registered with stereotactic CT. In the clinical study, target contours were compared between stereotactic MRI and diagnostic MRI co-registered with stereotactic CT. The mean errors of coordinates between images were < 1 mm in all measurement areas in both the phantom and clinical patient studies. The co-registration function implemented in LGP has sufficient geometrical accuracy to assure appropriate dose planning in clinical use.
- Open Access
- 6 March 2014
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (2) , 28-38
Effect of skull contours on dose calculations in Gamma Knife Perfexion stereotactic radiosurgery
In treatment planning of Leksell Gamma Knife (LGK) radiosurgery, the skull geometry defined by generally dedicated scalar measurement has a crucial effect on dose calculation. The LGK Perfexion (PFX) unit is equipped with a cone‐shaped collimator divided into eight sectors, and its configuration is entirely different from previous model C. Beam delivery on the PFX is made by a combination of eight sectors, but it is also mechanically available from one sector with the remaining seven blocked. Hence the treatment time using one sector is more likely to be affected by discrepancies in the skull shape than that of all sectors. In addition, the latest version (Ver. 10.1.1) of the treatment planning system Leksell GammaPlan (LGP) includes a new function to directly generate head surface contouring from computed tomography (CT) images in conjunction with the Leksell skull frame. This paper evaluates change of treatment time induced by different skull models. A simple simulation using a uniform skull radius of 80 mm and anthropomorphic phantom was implemented in LGP to find the trend between dose and skull measuring error. To evaluate the clinical effect, we performed an interobserver comparison of ruler measurement for 41 patients, and compared instrumental and CT‐based contours for 23 patients. In the phantom simulation, treatment time errors were less than 2% when the difference was within 3 mm. In the clinical cases, the variability of treatment time induced by the differences in interobserver measurements was less than 0. 91%, on average. Additionally the difference between measured and CT‐based contours was good, with a difference of (mean ±1 standard deviation) on average and a maximum of 3.4%. Although the skull model created from CT images reduced the dosimetric uncertainty caused by different measurers, these results showed that even manual skull measurement could reproduce the skull shape close to that of a patient's head within an acceptable range. PACS number: 87.53.Ly
- 6 March 2014
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (2) , 28-38
Open AccessEffect of skull contours on dose calculations in Gamma Knife Perfexion stereotactic radiosurgery
In treatment planning of Leksell Gamma Knife (LGK) radiosurgery, the skull geometry defined by generally dedicated scalar measurement has a crucial effect on dose calculation. The LGK Perfexion (PFX) unit is equipped with a cone‐shaped collimator divided into eight sectors, and its configuration is entirely different from previous model C. Beam delivery on the PFX is made by a combination of eight sectors, but it is also mechanically available from one sector with the remaining seven blocked. Hence the treatment time using one sector is more likely to be affected by discrepancies in the skull shape than that of all sectors. In addition, the latest version (Ver. 10.1.1) of the treatment planning system Leksell GammaPlan (LGP) includes a new function to directly generate head surface contouring from computed tomography (CT) images in conjunction with the Leksell skull frame. This paper evaluates change of treatment time induced by different skull models. A simple simulation using a uniform skull radius of 80 mm and anthropomorphic phantom was implemented in LGP to find the trend between dose and skull measuring error. To evaluate the clinical effect, we performed an interobserver comparison of ruler measurement for 41 patients, and compared instrumental and CT‐based contours for 23 patients. In the phantom simulation, treatment time errors were less than 2% when the difference was within 3 mm. In the clinical cases, the variability of treatment time induced by the differences in interobserver measurements was less than 0. 91%, on average. Additionally the difference between measured and CT‐based contours was good, with a difference of (mean ±1 standard deviation) on average and a maximum of 3.4%. Although the skull model created from CT images reduced the dosimetric uncertainty caused by different measurers, these results showed that even manual skull measurement could reproduce the skull shape close to that of a patient's head within an acceptable range. PACS number: 87.53.Ly
- Open Access
- 1 February 2014
- Vol. 76, 27-33
Useful base plate to support the head during Leksell skull frame placement in gamma knife perfexion radiosurgery.
We developed an original base plate to support both the patient's head and a Leksell stereotactic skull frame during frame placement in the supine position. The base plate is made of transparent acrylic board with holes at the posterior posts for injection of local anesthetics and maneuver of fixation screws through them. A stable and comfortable position of the patient's head in a supine position is obtained and maintained on this base plate with an air-pressure cuff beneath the patient's head. The patient is able to keep a stable, relaxed and comfortable posture during the procedures of skull frame placement.
- 1 February 2014
- Vol. 76, 27-33
Open AccessUseful base plate to support the head during Leksell skull frame placement in gamma knife perfexion radiosurgery.
We developed an original base plate to support both the patient's head and a Leksell stereotactic skull frame during frame placement in the supine position. The base plate is made of transparent acrylic board with holes at the posterior posts for injection of local anesthetics and maneuver of fixation screws through them. A stable and comfortable position of the patient's head in a supine position is obtained and maintained on this base plate with an air-pressure cuff beneath the patient's head. The patient is able to keep a stable, relaxed and comfortable posture during the procedures of skull frame placement.
- Open Access
- 17 December 2013
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (3) , 518-526
Simulational study of a dosimetric comparison between a Gamma Knife treatment plan and an intensity-modulated radiotherapy plan for skull base tumors
Fractionated stereotactic radiotherapy (SRT) is performed with a linear accelerator-based system such as Novalis. Recently, Gamma Knife Perfexion (PFX) featured the Extend system with relocatable fixation devices available for SRT. In this study, the dosimetric results of these two modalities were compared from the viewpoint of conformity, heterogeneity and gradient in target covering. A total of 14 patients with skull base tumors were treated with Novalis intensity-modulated (IM)-SRT. Treatment was planned on an iPlan workstation. Five- to seven-beam IM-SRT was performed in 14–18 fractions with a fraction dose of 2.5 or 3 Gy. With these patients' data, additional treatment planning was simulated using a GammaPlan workstation for PFX-SRT. Reference CT images with planning structure contour sets on iPlan, including the planning target volume (PTV, 1.1–102.2 ml) and organs at risk, were exported to GammaPlan in DICOM-RT format. Dosimetric results for Novalis IM-SRT and PFX-SRT were evaluated in the same prescription doses. The isocenter number of PFX was between 12 and 50 at the isodose contour of 50–60%. The PTV coverage was 95–99% for Novalis and 94–98% for PFX. The conformity index (CI) was 1.11–1.61 and 1.04–1.15, the homogeneity index (HI) was 1.1–3.62 and 2.3–3.25, and the gradient index (GI) was 3.72–7.97 and 2.54–3.39 for Novalis and PFX, respectively. PTV coverage by Novalis and PFX was almost equivalent. PFX was superior in CI and GI, and Novalis was better in HI. Better conformality would be achieved by PFX, when the homogeneity inside tumors is less important.
- 17 December 2013
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 55 (3) , 518-526
Open AccessSimulational study of a dosimetric comparison between a Gamma Knife treatment plan and an intensity-modulated radiotherapy plan for skull base tumors
Fractionated stereotactic radiotherapy (SRT) is performed with a linear accelerator-based system such as Novalis. Recently, Gamma Knife Perfexion (PFX) featured the Extend system with relocatable fixation devices available for SRT. In this study, the dosimetric results of these two modalities were compared from the viewpoint of conformity, heterogeneity and gradient in target covering. A total of 14 patients with skull base tumors were treated with Novalis intensity-modulated (IM)-SRT. Treatment was planned on an iPlan workstation. Five- to seven-beam IM-SRT was performed in 14–18 fractions with a fraction dose of 2.5 or 3 Gy. With these patients' data, additional treatment planning was simulated using a GammaPlan workstation for PFX-SRT. Reference CT images with planning structure contour sets on iPlan, including the planning target volume (PTV, 1.1–102.2 ml) and organs at risk, were exported to GammaPlan in DICOM-RT format. Dosimetric results for Novalis IM-SRT and PFX-SRT were evaluated in the same prescription doses. The isocenter number of PFX was between 12 and 50 at the isodose contour of 50–60%. The PTV coverage was 95–99% for Novalis and 94–98% for PFX. The conformity index (CI) was 1.11–1.61 and 1.04–1.15, the homogeneity index (HI) was 1.1–3.62 and 2.3–3.25, and the gradient index (GI) was 3.72–7.97 and 2.54–3.39 for Novalis and PFX, respectively. PTV coverage by Novalis and PFX was almost equivalent. PFX was superior in CI and GI, and Novalis was better in HI. Better conformality would be achieved by PFX, when the homogeneity inside tumors is less important.
- 19 November 2013
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (1) , 22-29
Efficacy of magnetic resonance imaging at 3 T compared with 1.5 T in small pituitary tumors for stereotactic radiosurgery planning
The objective of this study was to determine the value of high-field magnetic resonance imaging and to clarify the characteristics of each image among three-dimensional gradient echo (3D-GRE), two-dimensional spin echo (2D-SE) and inversion recovery (2D-IR) sequences used as contrast-enhanced T1-weighted images for stereotactic irradiation treatment planning of sellar lesions. Pulse sequences of 2D-SE and 3D-spoiled gradient recalled acquisition in the steady state (3D-SPGR) using GRE at 1.5 T and 2D-IR and 3D-fast SPGR (3D-FSPGR) at 3 T after injection of contrast material were acquired for 14 small pituitary tumors. As quantitative methods, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated using a region-of-interest analysis. There was no significant difference in SNR between 1.5-T SPGR and 3-T FSPGR, while 3-T IR was superior to 1.5-T SE. The 2D-SE and -IR provided significantly better CNR than 3D-GRE between tumor and normal structures. Three Tesla was found to be superior to 1.5 T in distinguishing tumors from the normal sellar structure. Optimal dose planning will utilize each advantage of imaging; 3D-GRE allows high-resolution acquisition and 2D-SE and -IR can offer better tissue contrast.
- 19 November 2013
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 32 (1) , 22-29
Efficacy of magnetic resonance imaging at 3 T compared with 1.5 T in small pituitary tumors for stereotactic radiosurgery planning
The objective of this study was to determine the value of high-field magnetic resonance imaging and to clarify the characteristics of each image among three-dimensional gradient echo (3D-GRE), two-dimensional spin echo (2D-SE) and inversion recovery (2D-IR) sequences used as contrast-enhanced T1-weighted images for stereotactic irradiation treatment planning of sellar lesions. Pulse sequences of 2D-SE and 3D-spoiled gradient recalled acquisition in the steady state (3D-SPGR) using GRE at 1.5 T and 2D-IR and 3D-fast SPGR (3D-FSPGR) at 3 T after injection of contrast material were acquired for 14 small pituitary tumors. As quantitative methods, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated using a region-of-interest analysis. There was no significant difference in SNR between 1.5-T SPGR and 3-T FSPGR, while 3-T IR was superior to 1.5-T SE. The 2D-SE and -IR provided significantly better CNR than 3D-GRE between tumor and normal structures. Three Tesla was found to be superior to 1.5 T in distinguishing tumors from the normal sellar structure. Optimal dose planning will utilize each advantage of imaging; 3D-GRE allows high-resolution acquisition and 2D-SE and -IR can offer better tissue contrast.