Patient‐specific resurfacing implant knee surgery in subjects with early osteoarthritis results in medial pivot and lateral femoral rollback during flexion: a retrospective pilot study
Open Access
- 3 October 2021
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (4) , 1247-1266
Abstract
Purpose: Metallic resurfacing implants have been developed for the treatment of early, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who do not fulfill the criteria for unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) or are too old for biological treatment. Although clinical evidence has been collected for different resurfacing types, the in vivo post‐operative knee kinematics remain unknown. The present study aims to analyze the knee kinematics in subjects with patient‐specific episealer implants. This study hypothesized that patient‐specific resurfacing implants would lead to knee kinematics close to healthy knees, resulting in medial pivot and a high degree of femoral rollback during flexion.Methods: Retrospective study design. Fluoroscopic analysis during unloaded flexion–extension and loaded lunge was conducted at > 12 months post‐surgery in ten episealer knees, and compared to ten healthy knees. Pre‐ and post‐operative clinical data of the episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health, and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaires.Results: A consistent medial pivot was observed in both episealer and healthy knees. Non‐significant differences were found in the unloaded (p = 0.15) and loaded (p = 0.51) activities. Although lateral rollback was observed in both groups, it was significantly higher for the episealer knees in both the unloaded (p = 0.02) and loaded (p = 0.01) activities. Coupled axial rotation was significantly higher in the unloaded (p = 0.001) but not in the loaded (p = 0.06) activity in the episealer knees. Improved scores were observed at 1‐year post‐surgery in the episealer subjects for the VAS (p = 0.001), KOOS (p = 0.001) and EQ Health (p = 0.004).Conclusion: At 12 month follow‐up, a clear physiological knee kinematics pattern of medial pivot, lateral femoral rollback and coupled axial external femoral rotation during flexion was observed in patients treated with an episealer resurfacing procedure. However, higher femoral rollback and axial external rotation in comparison to healthy knees was observed, suggesting possible post‐operative muscle weakness and consequent insufficient stabilization at high flexion.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (EH 422‐2‐1/MO 3865‐1‐1, TR 1657/1‐1)
- Charité – Universitätsmedizin Berlin
- Deutsche Forschungsgemeinschaft (EH 422-2-1/MO 3865-1-1, TR 1657/1-1)
- Charité - Universitätsmedizin Berlin
This publication has 28 references indexed in Scilit:
- Focal femoral condyle resurfacingThe Bone & Joint Journal, 2013
- Autologous chondrocyte implantation for osteochondral lesions in the knee using a bilayer collagen membrane and bone graftThe Journal of Bone and Joint Surgery. British volume, 2012
- The quality of bone surfaces may govern the use of model based fluoroscopy in the determination of joint laxityMedical Engineering & Physics, 2012
- Unicompartmental knee replacement for patients with partial thickness cartilage loss in the affected compartmentThe Knee, 2011
- Effects of preoperative neuromuscular electrical stimulation on quadriceps strength and functional recovery in total knee arthroplasty. A pilot studyBMC Musculoskeletal Disorders, 2010
- Factors associated with reduced early survival in the Oxford phase III medial unicompartment knee replacementThe Knee, 2010
- The knee in full flexionThe Journal of Bone and Joint Surgery. British volume, 2009
- A Prospective Study of Autologous Chondrocyte Implantation in Patients with Failed Prior Treatment for Articular Cartilage Defect of the KneeThe American Journal of Sports Medicine, 2008
- Articular damage caused by metal plugs in a rabbit model for treatment of localized cartilage defectsOsteoarthritis and Cartilage, 2007
- Safety of, and biological and functional response to, a novel metallic implant for the management of focal full‐thickness cartilage defects: Preliminary assessment in an animal model out to 1 yearJournal of Orthopaedic Research, 2006