ATAdam Trepczynski

Adam Trepczynski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Adam Trepczynski has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Georg N. Duda

    Julius Wolff Institute Berlin Institute of Health at Charité – Universitätsmedizin Berlin Berlin Germany

    8 shared publications
  • Philippe Moewis

    Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany

    7 shared publications
  • Georg Bergmann

    Julius Wolff Institute, Charité - Universitätsmedizin Berlin, Berlin, Germany

    3 shared publications
  • Hagen Hommel

    Krankenhaus Märkisch-Oderland GmBH, Wriezen, Germany

    3 shared publications
  • Leonie Krahl

    <!--1--> Berlin Institute of Health at Charité‐Universitätsmedizin Berlin Julius Wolff Institute Augustenburger Platz 1 13353 Berlin Germany

    3 shared publications
  • Philipp von Roth

    Julius Wolff Institute and Center for Musculoskeletal Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany

    3 shared publications

Latest Publications

  • Open Access

    Comparison of global and local optimization methods for intensity-based 2D–3D registration

    by Marko Leskovar, Mark Heyland, Adam Trepczynski, Stefan Zachow


  • Knieendoprothetik: Biomechanik des Kniegelenks

    by Georg N. Duda, Philippe Moewis, Hagen Hommel, Markus O. Heller, William R. Taylor, Georg Bergmann, Adam Trepczynski

  • Loading of the Knee Joint After Total Knee Arthroplasty

    by P. Moewis, A. Trepczynski, A. Bender, G. N. Duda, P. Damm

  • Open Access

    Dynamic Knee Joint Line Orientation Is Not Predictive of Tibio-Femoral Load Distribution During Walking

    by Adam Trepczynski, Philippe Moewis, Philipp Damm, Pascal Schütz, Jörn Dymke, Hagen Hommel, William R. Taylor, Georg N. Duda

    Some approaches in total knee arthroplasty aim for an oblique joint line to achieve an even medio-lateral load distribution across the condyles during the stance phase of gait. While there is much focus on the angulation of the joint line in static frontal radiographs, precise knowledge of the associated dynamic joint line orientation and the internal joint loading is limited. The aim of this study was to analyze how static alignment in frontal radiographs relates to dynamic alignment and load distribution, based on direct measurements of the internal joint loading and kinematics. A unique and novel combination of telemetrically measured in vivo knee joint loading and simultaneous internal joint kinematics derived from mobile fluoroscopy (“CAMS-Knee dataset”) was employed to access the dynamic alignment and internal joint loading in 6 TKA patients during level walking. Static alignment was measured in standard frontal postoperative radiographs while external adduction moments were computed based on ground reaction forces. Both static and dynamic parameters were analyzed to identify correlations using linear and non-linear regression. At peak loading during gait, the joint line was tilted laterally by 4°–7° compared to the static joint line in most patients. This dynamic joint line tilt did not show a strong correlation with the medial force (R2: 0.17) or with the mediolateral force distribution (pseudo R2: 0.19). However, the external adduction moment showed a strong correlation with the medial force (R2: 0.85) and with the mediolateral force distribution (pseudo R2: 0.78). Alignment measured in static radiographs has only limited predictive power for dynamic kinematics and loading, and even the dynamic orientation of the joint line is not an important factor for the medio-lateral knee load distribution. Preventive and rehabilitative measures should focus on the external knee adduction moment based on the vertical and horizontal components of the ground reaction forces.


  • Open Access

    Patient‐specific resurfacing implant knee surgery in subjects with early osteoarthritis results in medial pivot and lateral femoral rollback during flexion: a retrospective pilot study

    by Philippe Moewis, René Kaiser, Adam Trepczynski, Christoph von Tycowicz, Leonie Krahl, Ansgar Ilg, Johannes Holz, Georg N. Duda

    Purpose: Metallic resurfacing implants have been developed for the treatment of early, small, condylar and trochlear osteoarthritis (OA) lesions. They represent an option for patients who do not fulfill the criteria for unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA) or are too old for biological treatment. Although clinical evidence has been collected for different resurfacing types, the in vivo post‐operative knee kinematics remain unknown. The present study aims to analyze the knee kinematics in subjects with patient‐specific episealer implants. This study hypothesized that patient‐specific resurfacing implants would lead to knee kinematics close to healthy knees, resulting in medial pivot and a high degree of femoral rollback during flexion.Methods: Retrospective study design. Fluoroscopic analysis during unloaded flexion–extension and loaded lunge was conducted at > 12 months post‐surgery in ten episealer knees, and compared to ten healthy knees. Pre‐ and post‐operative clinical data of the episealer knees were collected using a visual analog scale (VAS), the EQ 5d Health, and the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaires.Results: A consistent medial pivot was observed in both episealer and healthy knees. Non‐significant differences were found in the unloaded (p = 0.15) and loaded (p = 0.51) activities. Although lateral rollback was observed in both groups, it was significantly higher for the episealer knees in both the unloaded (p = 0.02) and loaded (p = 0.01) activities. Coupled axial rotation was significantly higher in the unloaded (p = 0.001) but not in the loaded (p = 0.06) activity in the episealer knees. Improved scores were observed at 1‐year post‐surgery in the episealer subjects for the VAS (p = 0.001), KOOS (p = 0.001) and EQ Health (p = 0.004).Conclusion: At 12 month follow‐up, a clear physiological knee kinematics pattern of medial pivot, lateral femoral rollback and coupled axial external femoral rotation during flexion was observed in patients treated with an episealer resurfacing procedure. However, higher femoral rollback and axial external rotation in comparison to healthy knees was observed, suggesting possible post‐operative muscle weakness and consequent insufficient stabilization at high flexion.


  • Retention of Posterior Cruciate Ligament Alone May Not Achieve Physiological Knee Joint Kinematics After Total Knee Arthroplasty

    by Philippe Moewis, Georg N. Duda, Adam Trepczynski, Leonie Krahl, Christoph K. Boese, Hagen Hommel

    Background: The apparently physiological kinematics of the bicruciate-stabilized total knee arthroplasty (BCS TKA) systems have been attributed to the anterior and posterior post-cam mechanism. Although comparisons between TKA designs with either a retained or a sacrificed cruciate ligament have been conducted, we are not aware of any analyses of 2 implants with identical bearing geometry but different cruciate-ligament strategies under equal loading conditions. Knowledge about the kinematic effect of the different cruciate ligament strategies would potentially be valuable to facilitate preoperative planning and decision-making with regard to selecting the most appropriate implant for a patient. Methods: This retrospective study included 20 patients: 10 treated with a BCS and 10 treated with a cruciate retaining (CR) TKA. Fluoroscopic analyses during high-flexion activities (unloaded flexion-extension and loaded lunge) were conducted at 24 months postsurgery. All patients completed the Knee Society Score, Forgotten Joint Score, and High-Flexion Knee Score questionnaires preoperatively and postoperatively. Results: The BCS cohort showed greater femoral lateral rollback as well as a medial pivot in both activities. In contrast, the CR cohort showed a significant increase in anterior translation on the medial compartment as well as almost absent femoral lateral rollback. Higher clinical scores were observed in the BCS cohort. Conclusions: At 24 months postsurgery, despite equal bearing geometry, retention of the posterior cruciate ligament in the CR cohort apparently was insufficient to reduce anterior shift. The BCS cohort showed expected knee joint kinematics; however, the kinematics in this cohort could eventually benefit from a smooth transition between the interchanging surfaces. Further investigation should be focused on the surgical technique and its interaction with the TKA design. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


  • Open Access

    Author Correction: Weight Bearing Activities change the Pivot Position after Total Knee Arthroplasty

    by Philippe Moewis, Hagen Hommel, Adam Trepczynski, Leonie Krahl, Philipp von Roth, Georg N. Duda

    An amendment to this paper has been published and can be accessed via a link at the top of the paper.


  • Open Access

    Author Correction: Tibio-Femoral Contact Force Distribution is Not the Only Factor Governing Pivot Location after Total Knee Arthroplasty

    by A. Trepczynski, I. Kutzner, P. Schütz, J. Dymke, R. List, P. von Roth, P. Moewis, G. Bergmann, W. R. Taylor, G. N. Duda

    A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

  • Open Access

    Tibio-Femoral Contact Force Distribution is Not the Only Factor Governing Pivot Location after Total Knee Arthroplasty

    by A. Trepczynski, I. Kutzner, P. Schütz, J. Dymke, R. List, P. von Roth, P. Moewis, G. Bergmann, W. R. Taylor, G. N. Duda

    Total knee arthroplasty aims to mimic the natural knee kinematics by optimizing implant geometry, but it is not clear how loading relates to tibio-femoral anterior-posterior translation or internal-external pivoting. We hypothesised that the point of pivot in the transverse plane is governed by the location of the highest axial force. Tibio-femoral loading was measured using an instrumented tibial component in six total knee arthroplasty patients (aged 65–80y, 5–7y post-op) during 5–6 squat repetitions, while knee kinematics were captured using a mobile video-fluoroscope. In the range of congruent tibio-femoral contact the medial femoral condyle remained approximately static while the lateral condyle translated posteriorly by 4.1 mm (median). Beyond the congruent range, the medial and lateral condyle motions both abruptly changed to anterior sliding by 4.6 mm, and 2.6 mm respectively. On average, both the axial loading and pivot position were more medial near extension, and transferred to the lateral side in flexion. However, no consistent relationship between pivoting and load distribution was found across all patients throughout flexion, with R2 values ranging from 0.00 to 0.65. Tibio-femoral kinematics is not related to the load distribution alone: medial loading of the knee does not necessarily imply a medial pivot location.


  • Open Access

    Impact of antagonistic muscle co-contraction on in vivo knee contact forces

    by Adam Trepczynski, Ines Kutzner, Verena Schwachmeyer, Markus O. Heller, Tilman Pfitzner, Georg N. Duda

    The onset and progression of osteoarthritis, but also the wear and loosening of the components of an artificial joint, are commonly associated with mechanical overloading of the structures. Knowledge of the mechanical forces acting at the joints, together with an understanding of the key factors that can alter them, are critical to develop effective treatments for restoring joint function. While static anatomy is usually the clinical focus, less is known about the impact of dynamic factors, such as individual muscle recruitment, on joint contact forces. In this study, instrumented knee implants provided accurate in vivo tibio-femoral contact forces in a unique cohort of 9 patients, which were used as input for subject specific musculoskeletal models, to quantify the individual muscle forces during walking and stair negotiation. Even between patients with a very similar self-selected gait speed, the total tibio-femoral peak forces varied 1.7-fold, but had only weak correlation with static alignment (varus/valgus). In some patients, muscle co-contraction of quadriceps and gastrocnemii during walking added up to 1 bodyweight (~ 50%) to the peak tibio-femoral contact force during late stance. The greatest impact of co-contraction was observed in the late stance phase of stair ascent, with an increase of the peak tibio-femoral contact force by up to 1.7 bodyweight (66%). Treatment of diseased and failed joints should therefore not only be restricted to anatomical reconstruction of static limb axes alignment. The dynamic activation of muscles, as a key modifier of lower limb biomechanics, should also be taken into account and thus also represents a promising target for restoring function, patient mobility, and preventing future joint failure. German Clinical Trials Register: ID: DRKS00000606 , date: 05.11.2010.