Intraocular robotic interventional surgical system (IRISS): Semi‐automated OCT‐guided cataract removal
Open Access
- 28 August 2018
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (6) , e1949
Abstract
Background With the development of laser‐assisted platforms, the outcomes of cataract surgery have been improved by automating several procedures. The cataract‐extraction step continues to be manually performed, but due to deficiencies in sensing capabilities, surgical complications such as posterior capsule rupture and incomplete cataract removal remain. Methods An optical coherence tomography (OCT) system is integrated into our intraocular robotic interventional surgical system (IRISS) robot. The OCT images are used for preoperative planning and intraoperative intervention in a series of automated procedures. Real‐time intervention allows surgeons to evaluate the progress and override the operation. Results The developed system was validated by performing lens extraction on 30 postmortem pig eyes. Complete lens extraction was achieved on 25 eyes, and “almost complete” extraction was achieved on the remainder due to an inability to image small lens particles behind the iris. No capsule rupture was found. Conclusion The IRISS successfully demonstrated semiautomated OCT‐guided lens removal with real‐time supervision and intervention.Keywords
Funding Information
- National Eye Institute (5R21EY024065-02)
This publication has 29 references indexed in Scilit:
- Integrative Advances for OCT-Guided Ophthalmic Surgery and Intraoperative OCT: Microscope Integration, Surgical Instrumentation, and Heads-Up Display Surgeon FeedbackPLOS ONE, 2014
- Quantitative assessment of manual and robotic microcannulation for eye surgery using new eye modelThe International Journal of Medical Robotics and Computer Assisted Surgery, 2014
- Femtosecond laser–assisted cataract surgeryJournal of Cataract & Refractive Surgery, 2013
- Robot-assisted intraocular surgery: development of the IRISS and feasibility studies in an animal modelEye, 2013
- Automatic segmentation of anterior segment optical coherence tomography imagesJournal of Biomedical Optics, 2013
- Global estimates of visual impairment: 2010British Journal of Ophthalmology, 2011
- Three-Dimensional 1060-nm OCT: Choroidal Thickness Maps in Normal Subjects and Improved Posterior Segment Visualization in Cataract PatientsInvestigative Ophthalmology & Visual Science, 2010
- Robot-Assisted Vitreoretinal SurgeryOphthalmology, 2009
- High‐resolution ultrasound imaging of the eye – a reviewClinical & Experimental Ophthalmology, 2009
- National cataract surgery survey 1997-8: a report of the results of the clinical outcomesBritish Journal of Ophthalmology, 1999