Abstract
This article investigates friction welding (FW) between electrolytic tough pitch copper (Cu) and 304 stainless steel (SS) in a rod joint configuration with a 16 mm diameter, utilizing the continuous drive FW technique. This welding was conducted by varying friction pressure (FP) and upset pressure (UP), while other parameters remained constant. From the welding parameters, the “coefficient of friction” (COF) was estimated, which is found in the range of 0.18–0.40. The concept of the COF is widely applied in both science and engineering. The variation in COF during the FW process affected the torque, which ranged from 12.13 to 16.2 Nm, and the power, which varied between 2094 and 2902 W. Changes in COF, torque, and power were governed by the applied pressure, which, in turn, influenced the strength of the welded joints. Notably, higher COF values corresponded to significant improvements in the tensile strength of the joint. All samples fractured on the Cu side, away from the interface, with the maximum recorded tensile strength reaching 202 MPa.

This publication has 13 references indexed in Scilit: