Hardik D. Vyas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hardik D. Vyas has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Tapan Patel
Institute for Plasma Research, Gandhinagar, Gujarat, India
4 shared publications U. K. Baruah
Institute for Plasma Research, Gandhinagar, Gujarat, India
4 shared publicationsVishvesh Badheka
Department of Mechanical Engineering, School of Technology, Pandit Deendayal EnergyUniversity, Gandhinagar, India
3 shared publicationsM. R. Jana
Institute for Plasma Research, Gandhinagar, Gujarat, India
2 shared publications- M. R. Jana
Institute for Plasma Research, Gandhinagar, Gujarat, India
2 shared publications P. Chaudhuri
Institute for Plasma Research, Gandhinagar, Gujarat, India
2 shared publications
Latest Publications
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2456-2462
Fabrication of Prototype Ion Extractor Grid and Its 500 s Long-Pulse Operation With 1.63 MW/m 2 Heat Load
A neutral beam injection (NBI) system works as an auxiliary heating system for Steady-State Superconducting Tokamak-1 (SST-1) with a capacity to inject power up to 1.7 MW at 55 keV extraction voltage. NBI consists of a multiaperture three-grid ion extraction system made up of oxygen-free electronic (OFE) copper to obtain a high-power focused beam. The fabrication of ion extractor grids is complex due to the requirement of precision dimensional tolerances during the machining of the grid and other technologies involved, e.g., electrodeposition (ED) of copper for making embedded water cooling channels. This article describes an in-house technology development for the fabrication of a prototype ion extraction grid (PG) of size $150\times 60$ mm, which consists of four wavy embedded semicircular (R $1.1~\pm ~0.05$ mm) cooling channels. There are 19 through holes, each of 8mm in diameter, lying between the cooling channels. To study the long pulse operation, this prototype grid is tested with a heat flux of 1.63 MW/m2 for 500 s pulse (2 cycles with 30 min cool down period) generated from 16.6 kW electron beam (EB) power. Inlet water at ~ $26~^{\circ }$ C is supplied to the inlet water header with 0.078 kg/s flow rate at an inlet pressure of 4 bar to remove the incident heat flux. The online surface temperature of the PG is measured with an infrared (IR) camera. The average surface temperature measured on PG is ~ $~48~^{\circ}$ C± $2~^{\circ }$ C. Inlet and outlet water temperature is measured using a resistance temperature detector (RTD). The bulk temperature rise $\Delta $ Tw is ~ $17.8~^{\circ }$ C and $18.26~^{\circ }$ C for shot 1 and shot 2, respectively, which corresponds to the absorbed heat flux of ~0.6 MW/m2, and the absorption coefficient of ~37%. After the high heat flux test (HHFT), the measured leak rate is ~ $3.9\lt 10^{-10}$ mbar−1/s. This study will help us in the fabrication of an actual-size grid, which is in progress.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2456-2462
Fabrication of Prototype Ion Extractor Grid and Its 500 s Long-Pulse Operation With 1.63 MW/m 2 Heat Load
A neutral beam injection (NBI) system works as an auxiliary heating system for Steady-State Superconducting Tokamak-1 (SST-1) with a capacity to inject power up to 1.7 MW at 55 keV extraction voltage. NBI consists of a multiaperture three-grid ion extraction system made up of oxygen-free electronic (OFE) copper to obtain a high-power focused beam. The fabrication of ion extractor grids is complex due to the requirement of precision dimensional tolerances during the machining of the grid and other technologies involved, e.g., electrodeposition (ED) of copper for making embedded water cooling channels. This article describes an in-house technology development for the fabrication of a prototype ion extraction grid (PG) of size $150\times 60$ mm, which consists of four wavy embedded semicircular (R $1.1~\pm ~0.05$ mm) cooling channels. There are 19 through holes, each of 8mm in diameter, lying between the cooling channels. To study the long pulse operation, this prototype grid is tested with a heat flux of 1.63 MW/m2 for 500 s pulse (2 cycles with 30 min cool down period) generated from 16.6 kW electron beam (EB) power. Inlet water at ~ $26~^{\circ }$ C is supplied to the inlet water header with 0.078 kg/s flow rate at an inlet pressure of 4 bar to remove the incident heat flux. The online surface temperature of the PG is measured with an infrared (IR) camera. The average surface temperature measured on PG is ~ $~48~^{\circ}$ C± $2~^{\circ }$ C. Inlet and outlet water temperature is measured using a resistance temperature detector (RTD). The bulk temperature rise $\Delta $ Tw is ~ $17.8~^{\circ }$ C and $18.26~^{\circ }$ C for shot 1 and shot 2, respectively, which corresponds to the absorbed heat flux of ~0.6 MW/m2, and the absorption coefficient of ~37%. After the high heat flux test (HHFT), the measured leak rate is ~ $3.9\lt 10^{-10}$ mbar−1/s. This study will help us in the fabrication of an actual-size grid, which is in progress.
- 27 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2437-2443
Status of the Progress of Fabrication of High Power Prototype Ion Extractor Grid for NBI System
The steady-state superconducting tokamak (SST) neutral beam injection (NBI) system has an ion extractor system that consists of three grids, each having a number of shaped apertures to extract a 90-A hydrogen ion current at 55 kV. During beam operation, the grid received heat load, which is removed by embedded water cooling channels. The ion optical design of grids demands stringent tolerances in various dimensions, which makes the complexity in the engineering design and fabrication. This article describes the status of the progress of the work done toward the development of technologies and routes for the successful fabrication of the prototype acceleration grid (PAG). Friction welding (FW) of a dissimilar metals joint of SS304L rod to oxygen-free electronic (OFE) copper plate was done for making water headers to supply water. scanning electron microscope (SEM) and energy-dispersive x-ray spectroscopy (EDS) analysis of FW samples shows that recrystallization occurred at the weld interface, and a fine grain is formed at the Cu side due to frictional heat and forging pressure. Elemental diffusion takes place across the joint interface, which improves metallurgical bonding between SS and Cu. CMM measurement of the CNC-machined grid shows that the dimensions are as per the design specification. Machined cooling channels and manifolds’ grooves are covered by a technique called copper electrodeposition (ED). Continuity of the cooling channels is checked by a liquid crystal display (LCD) display test, and radiography test (RT) results are satisfactory. Steady-state computational fluid dynamics (CFD) analysis with 0.44-MW/m2 heat load (max.) shows that maximum surface temperature is $150~^{\circ }$ C with a 0.22-kg/s water flow rate at $20~^{\circ }$ C and a velocity of 10.5 m/s. Knowledge gained from the prototype grid (PG) fabrication and acceptance test results shall be used for the fabrication of actual-size ion extractor grids for the NBI system to support Indian fusion program.
- 27 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2437-2443
Status of the Progress of Fabrication of High Power Prototype Ion Extractor Grid for NBI System
The steady-state superconducting tokamak (SST) neutral beam injection (NBI) system has an ion extractor system that consists of three grids, each having a number of shaped apertures to extract a 90-A hydrogen ion current at 55 kV. During beam operation, the grid received heat load, which is removed by embedded water cooling channels. The ion optical design of grids demands stringent tolerances in various dimensions, which makes the complexity in the engineering design and fabrication. This article describes the status of the progress of the work done toward the development of technologies and routes for the successful fabrication of the prototype acceleration grid (PAG). Friction welding (FW) of a dissimilar metals joint of SS304L rod to oxygen-free electronic (OFE) copper plate was done for making water headers to supply water. scanning electron microscope (SEM) and energy-dispersive x-ray spectroscopy (EDS) analysis of FW samples shows that recrystallization occurred at the weld interface, and a fine grain is formed at the Cu side due to frictional heat and forging pressure. Elemental diffusion takes place across the joint interface, which improves metallurgical bonding between SS and Cu. CMM measurement of the CNC-machined grid shows that the dimensions are as per the design specification. Machined cooling channels and manifolds’ grooves are covered by a technique called copper electrodeposition (ED). Continuity of the cooling channels is checked by a liquid crystal display (LCD) display test, and radiography test (RT) results are satisfactory. Steady-state computational fluid dynamics (CFD) analysis with 0.44-MW/m2 heat load (max.) shows that maximum surface temperature is $150~^{\circ }$ C with a 0.22-kg/s water flow rate at $20~^{\circ }$ C and a velocity of 10.5 m/s. Knowledge gained from the prototype grid (PG) fabrication and acceptance test results shall be used for the fabrication of actual-size ion extractor grids for the NBI system to support Indian fusion program.
- 26 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2450-2455
Estimation of the Coefficient of Friction in Dissimilar Metals of Cu to SS Friction Weld Joints for NBI Ion Extractor Grid Fabrication
This article investigates friction welding (FW) between electrolytic tough pitch copper (Cu) and 304 stainless steel (SS) in a rod joint configuration with a 16 mm diameter, utilizing the continuous drive FW technique. This welding was conducted by varying friction pressure (FP) and upset pressure (UP), while other parameters remained constant. From the welding parameters, the “coefficient of friction” (COF) was estimated, which is found in the range of 0.18–0.40. The concept of the COF is widely applied in both science and engineering. The variation in COF during the FW process affected the torque, which ranged from 12.13 to 16.2 Nm, and the power, which varied between 2094 and 2902 W. Changes in COF, torque, and power were governed by the applied pressure, which, in turn, influenced the strength of the welded joints. Notably, higher COF values corresponded to significant improvements in the tensile strength of the joint. All samples fractured on the Cu side, away from the interface, with the maximum recorded tensile strength reaching 202 MPa.
- 26 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 54 (6) , 2450-2455
Estimation of the Coefficient of Friction in Dissimilar Metals of Cu to SS Friction Weld Joints for NBI Ion Extractor Grid Fabrication
This article investigates friction welding (FW) between electrolytic tough pitch copper (Cu) and 304 stainless steel (SS) in a rod joint configuration with a 16 mm diameter, utilizing the continuous drive FW technique. This welding was conducted by varying friction pressure (FP) and upset pressure (UP), while other parameters remained constant. From the welding parameters, the “coefficient of friction” (COF) was estimated, which is found in the range of 0.18–0.40. The concept of the COF is widely applied in both science and engineering. The variation in COF during the FW process affected the torque, which ranged from 12.13 to 16.2 Nm, and the power, which varied between 2094 and 2902 W. Changes in COF, torque, and power were governed by the applied pressure, which, in turn, influenced the strength of the welded joints. Notably, higher COF values corresponded to significant improvements in the tensile strength of the joint. All samples fractured on the Cu side, away from the interface, with the maximum recorded tensile strength reaching 202 MPa.
- 5 August 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 82 (3) , 730-758
Characterization and Integrity Assessment of Friction-Welded Joints Between ETP-Cu and SS304L for Fusion Applications
- 5 August 2025
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 82 (3) , 730-758
Characterization and Integrity Assessment of Friction-Welded Joints Between ETP-Cu and SS304L for Fusion Applications
- 26 February 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 34 (10) , 9078-9098
Analysis of Mechanical and Microstructural Properties in Larger-Sized Electrolytic Tough Pitch Copper to SS304L Pipe Joints Produced by Friction Welding
- 26 February 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 34 (10) , 9078-9098
Analysis of Mechanical and Microstructural Properties in Larger-Sized Electrolytic Tough Pitch Copper to SS304L Pipe Joints Produced by Friction Welding
- 19 November 2024
- Published by Springer Nature in Welding in the World
- Vol. 69 (2) , 431-448
Influence of rotational speed on interfacial microstructure and tensile properties of friction welded Al-SS pipe joints
- 19 November 2024
- Published by Springer Nature in Welding in the World
- Vol. 69 (2) , 431-448
Influence of rotational speed on interfacial microstructure and tensile properties of friction welded Al-SS pipe joints
- 5 April 2024
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 81 (1) , 45-60
Friction Welding of ETP-Cu Plate to SS304L Round Bar: An Experimental Study on Asymmetrical Dissimilar Metal Joints
- 5 April 2024
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 81 (1) , 45-60
Friction Welding of ETP-Cu Plate to SS304L Round Bar: An Experimental Study on Asymmetrical Dissimilar Metal Joints
- Open Access
- 1 January 2022
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 832
Microstructure evolution and mechanical properties of continuous drive friction welded dissimilar copper-stainless steel pipe joints
- 1 January 2022
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 832
Open AccessMicrostructure evolution and mechanical properties of continuous drive friction welded dissimilar copper-stainless steel pipe joints