Controlled Pitch-Adjustment of Impeller Blades for an Intravascular Blood Pump
- 1 July 2012
- journal article
- biomedical engineering
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 58 (4) , 382-389
Abstract
Thousands of mechanical blood pumps are currently providing circulatory support, and the incidence of their use continues to increase each year. As the use of blood pumps becomes more pervasive in the treatment of those patients with congestive heart failure, critical advances in design features to address known limitations and the integration of novel technologies become more imperative. To advance the current state-of-the-art in blood pump design, this study investigates the inclusion of pitch-adjusting blade features in intravascular blood pumps as a means to increase energy transfer; an approach not explored to date. A flexible impeller prototype was constructed with a configuration to allow for a variable range of twisted blade geometries of 60–250°. Hydraulic experiments using a blood analog fluid were conducted to characterize the pressure-flow performance for each of these twisted positions. The flexible, twisted impeller was able to produce 1–25 mmHg for 0.5–4 L/min at rotational speeds of 5,000–8,000 RPM. For a given twisted position, the pressure rise was found to decrease as a function of increasing flow rate, as expected. Generally, a steady increase in the pressure rise was observed as a function of higher twisted degrees for a constant rotational speed. Higher rotational speeds for a specific twisted impeller configuration resulted in a more substantial pressure generation. The findings of this study support the continued exploration of this unique design approach in the development of intravascular blood pumps.Keywords
This publication has 12 references indexed in Scilit:
- A first‐in‐man study of the reitan catheter pump for circulatory support in patients undergoing high‐risk percutaneous coronary interventionCatheterization and Cardiovascular Interventions, 2009
- Pediatric Circulatory Support: Current Strategies and Future Directions. Biventricular and Univentricular Mechanical AssistanceASAIO Journal, 2008
- Long-Term Survival, Modes of Death, and Predictors of Mortality in Patients With Fontan SurgeryCirculation, 2008
- Numerical Design and Experimental Hydraulic Testing of an Axial Flow Ventricular Assist Device for Infants and ChildrenASAIO Journal, 2007
- An Expandable Percutaneous Catheter Pump for Left Ventricular SupportJACC, 2005
- Routine mechanical ventricular assist following the Norwood procedure—improved neurologic outcome and excellent hospital survivalThe Annals of Thoracic Surgery, 2004
- Surgical results of patients with a functional single ventricleEuropean Journal of Cardio-Thoracic Surgery, 2003
- Pediatric Circulatory Support SystemsASAIO Journal, 2002
- The History of Continuous‐Flow Blood PumpsArtificial Organs, 2000
- Surgical repair of tricuspid atresiaThorax, 1971