Amy L. Throckmorton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amy L. Throckmorton has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Steven G. Chopski

    Division of Quantitative Methods and Modeling, Office of Research and Standards, Office of Generic Drugs, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, Silver Spring, MD, USA

    6 shared publications
  • Jugal Y. Kapadia

    BioCirc Research Laboratory, Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, VA, USA

    5 shared publications
  • Sonya S. Bhavsar

    Department of Mechanical Engineering, School of Engineering, Virginia Commonwealth University

    5 shared publications
  • William B. Moskowitz

    Virginia Commonwealth Univ, Med Coll Virginia, Div Pediat Cardiol, Richmond, VA 23284 USA

    5 shared publications
  • Emily A. Downs

    Virginia Commonwealth University

    4 shared publications
  • Ajit P. Yoganathan

    Georgia Inst Technol, Wallace H Coulter Sch Biomed Engn, Atlanta, GA 30332 USA

    3 shared publications

Latest Publications

  • Dual‐Pump Support in the Inferior and Superior Vena Cavae of a Patient‐Specific Fontan Physiology

    by Amy L. Throckmorton, Sergio Lopez‐Isaza, William Moskowitz

    The implementation of simultaneous mechanical cavopulmonary assistance having blood pumps located in both of the vena cavae is investigated as an approach to treating patients with an ailing Fontan physiology. Identical intravascular blood pumps are employed to model the hemodynamic support of a patient‐specific Fontan. Pressure flow characteristics, energy gain calculations, and blood damage analyses are assessed for each model. The performance of the dual‐support scenario is compared to conditions of mechanical support in the inferior vena cava only and to a nonsupported cavopulmonary circuit. The blood pump in the superior vena cava generates pressures ranging from 1 to 22 mm Hg for flow rates of 1–4 L/min at operating speeds of 1250–2500 rpm. The blood pump in the inferior vena cava produces pressures at levels approximately 20% lower. The blood pumps positively augment the hydraulic energy in the total cavopulmonary connection circuit as a function of flow rate and rotational speed. Scalar stress levels and fluid residence times are at acceptable levels. Damage indices for the dual‐support case, however, are elevated slightly above 3.5%. These results suggest that concurrent, mechanical assistance of the inferior vena cava and superior vena cava in Fontan patients has the potential to be beneficial, but additional studies are needed to further explore this approach.


  • A Viable Therapeutic Option: Mechanical Circulatory Support of the Failing Fontan Physiology

    by Amy L. Throckmorton, Sergio Lopez-Isaza, Emily A. Downs, Steven G. Chopski, James J. Gangemi, William Moskowitz

    A blood pump specifically designed to augment flow from the great veins through the lungs would ameliorate the poor physiology of the failing univentricular circulation and result in a paradigm shift in the treatment strategy for Fontan patients. This study is the first to examine mechanical cavopulmonary assistance with a blood pump in the inferior vena cava (IVC) and hepatic blood flow. Five numerical models of mechanical cavopulmonary assistance were investigated using a three-dimensional, reconstructed, patient-specific Fontan circulation from magnetic resonance imaging data. Pressure flow characteristics of the axial blood pump, energy augmentation calculations for the cavopulmonary circulation with and without pump support, and hemolysis estimations were determined. In all of the pump-supported scenarios, a pressure increase of 7–9.5 mm Hg was achieved. The fluid power of the cavopulmonary circulation was also positive over the range of flow rates. No retrograde flow from the IVC into the hepatic circulation was evident during support cases. Vessel suction risk, however, was found for greater operating rotational speeds. Fluid shear stresses and hemolysis predictions remained at acceptable levels with normalized index of hemolysis estimations at 0.0001 g/100L. The findings of this study support the continued design and development of this blood pump technology for Fontan patients with progressive cardiovascular insufficiency. Validation of these flow and performance predictions will be completed in the next round of experimental testing with blood bag evaluation.


  • Uniquely shaped cardiovascular stents enhance the pressure generation of intravascular blood pumps

    by Amy L. Throckmorton, James P. Carr, William B. Moskowitz, James J. Gangemi, Christopher M. Haggerty, Ajit P. Yoganathan


  • Controlled Pitch-Adjustment of Impeller Blades for an Intravascular Blood Pump

    by Amy L. Throckmorton, Michael G. Sciolino, Emily A. Downs, Robert S. Saxman, Sergio López-Isaza, William B. Moskowitz

    Thousands of mechanical blood pumps are currently providing circulatory support, and the incidence of their use continues to increase each year. As the use of blood pumps becomes more pervasive in the treatment of those patients with congestive heart failure, critical advances in design features to address known limitations and the integration of novel technologies become more imperative. To advance the current state-of-the-art in blood pump design, this study investigates the inclusion of pitch-adjusting blade features in intravascular blood pumps as a means to increase energy transfer; an approach not explored to date. A flexible impeller prototype was constructed with a configuration to allow for a variable range of twisted blade geometries of 60–250°. Hydraulic experiments using a blood analog fluid were conducted to characterize the pressure-flow performance for each of these twisted positions. The flexible, twisted impeller was able to produce 1–25 mmHg for 0.5–4 L/min at rotational speeds of 5,000–8,000 RPM. For a given twisted position, the pressure rise was found to decrease as a function of increasing flow rate, as expected. Generally, a steady increase in the pressure rise was observed as a function of higher twisted degrees for a constant rotational speed. Higher rotational speeds for a specific twisted impeller configuration resulted in a more substantial pressure generation. The findings of this study support the continued exploration of this unique design approach in the development of intravascular blood pumps.


  • Twisted Cardiovascular Cages for Intravascular Axial Flow Blood Pumps to Support the Fontan Physiology

    by Amy L. Throckmorton, Emily A. Downs, John A. Hazelwood, Jonathan O. Monroe, Steven G. Chopski

    Failing single ventricle physiology represents an ongoing challenge in mechanical assist device development, requiring pressure augmentation in the cavopulmonary circuit, reduction of systemic venous pressure, and increased cardiac output to achieve hemodynamic stabilization. To meet these requirements, we are developing a percutaneously-placed, axial flow blood pump to support ailing single ventricle physiology in adolescents and adults. We have modified the outer cage of the device to serve as both a protective and functional design component. This study examined the performance of 3 cage geometries with varying directions of filament twist using numerical simulations and hydraulic experiments. All 3 cage and pump models performed in acceptable ranges to support Fontan patients. The cage design employing filaments that are twisted in the opposite direction to the impeller blades and in the direction of the diffuser blades (against-with) demonstrated superior performance by generating a pressure rise range of 5–38 mm Hg of flow rates of 0.5–6 l/min at rotational speeds of 5000–7000 rpm. The blood damage indices for all of the cages were found to be well below 2%, and the scalar stress levels were below 200 Pa. This study represents ongoing progress in the development of the impeller and cage assembly. Validation of the results will continue in experiments with blood bag evaluation as well as by particle image velocimetry measurements.


  • Laser Flow Measurements in an Idealized Total Cavopulmonary Connection With Mechanical Circulatory Assistance

    by Steven G. Chopski, Emily Downs, Christopher M. Haggerty, Ajit P. Yoganathan, Amy L. Throckmorton

    This study examined the interactive fluid dynamics between a cavopulmonary assist device and univentricular Fontan circulation. We conducted two-dimensional particle image velocimetry measurements on an idealized total cavopulmonary connection (TCPC) with an axial pump prototype intravascularly inserted into the inferior vena cava (IVC) and then in the IVC and the superior vena cava (SVC) for a dual-pump support case. The glass model of the TCPC consisted of rigid vessels having a diameter of 13.4 mm and a one-diameter vessel offset at the TCPC junction. Fluid velocity profiles were examined at a cardiac output of 3 L/min and SVC and IVC flow ratios of 30/70%, 40/60%, and 50/50% and pump rotational speeds from 3000 to 9000 rpm. In addition, cardiac outputs of 5 and 7 L/min were also examined. As compared to the flow profile with the pump present, the measured velocity field demonstrated the presence of rotational (i.e., out of plane) motion, which forced the higher-velocity regions toward the periphery of the vessel. As a result, few flow vortices were captured in the image plane downstream of the pump in the TCPC junction. However, the velocity profiles for all cases demonstrated the expected shunting preference of IVC flow toward the right pulmonary artery. Furthermore, the inclusion of the pump provided a pressure rise of 3 to 9 mm Hg, which would be sufficient to relieve systemic hypertension in Fontan patients with circulatory dysfunction.


  • Mechanical Cavopulmonary Assistance of a Patient-Specific Fontan Physiology: Numerical Simulations, Lumped Parameter Modeling, and Suction Experiments

    by Amy L. Throckmorton, James P. Carr, Sharjeel A. Tahir, Ryan Tate, Emily A. Downs, Sonya S. Bhavsar, Yi Wu, John D. Grizzard, William B. Moskowitz

    This study investigated the performance of a magnetically levitated, intravascular axial flow blood pump for mechanical circulatory support of the thousands of Fontan patients in desperate need of a therapeutic alternative. Four models of the extracardiac, total cavopulmonary connection (TCPC) Fontan configuration were evaluated to formulate numerical predictions: an idealized TCPC, a patient-specific TCPC per magnetic resonance imaging data, and each of these two models having a blood pump in the inferior vena cava (IVC). A lumped parameter model of the Fontan physiology was used to specify boundary conditions. Pressure-flow characteristics, energy gain calculations, scalar stress levels, and blood damage estimations were executed for each model. Suction limitation experiments using the Sylgard elastomer tubing were also conducted. The pump produced pressures of 1–16 mm Hg for 2000–6000 rpm and flow rates of 0.5–4.5 L/min. The pump inlet or IVC pressure was found to decrease at higher rotational speeds. Maximum scalar stress estimations were 3 Pa for the nonpump models and 290 Pa for the pump-supported cases. The blood residence times for the pump-supported cases were shorter (0.9 s) as compared with the nonsupported configurations (2.5 s). However, the blood damage indices were higher (1.5%) for the anatomic model with pump support. The pump successfully augmented pressure in the TCPC junction and increased the hydraulic energy of the TCPC as a function of flow rate and rotational speed. The suction experiments revealed minimal deformation (<3%) at 9000 rpm. The findings of this study support the continued design and development of this blood pump.


  • Filament Support Spindle for an Intravascular Cavopulmonary Assist Device

    by Amy L. Throckmorton, Jugal Y. Kapadia, Thomas M. Wittenschlaeger, Tanisha J. Medina, Hien Q. Hoang, Sonya S. Bhavsar

    We are developing an intravascular axial flow blood pump to support adolescent and adult Fontan patients. To protect the blood vessel, this pump has an outer cage with radially arranged filaments and a newly designed spindle at the pump outlet. The outlet spindle is included to limit the axial movement of the rotor and to house bearings that support the rotor. This study evaluates the impact of the outlet spindle on pump performance using computational fluid dynamics (CFD) and experimental testing of a prototype configuration. We measured the pressure–flow performance of the prototype with a protective cage using a blood analog fluid. The pump with the cage filaments and spindle generated 1 to 16 mm Hg of pressure rise for flow rates of 1 to 4 L/min at 4000 to 7000 rpm. The difference between the CFD predictions and experimental results was found to be approximately 9.8%. Scalar stress levels remained below 570 Pa with exposure times on the order of 1.5 s. These results are acceptable and support the continued development of this cavopulmonary assist device with an outlet spindle to reinforce the protective cage filament design.


  • Flexible Impeller Blades in an Axial Flow Pump for Intravascular Cavopulmonary Assistance of the Fontan Physiology

    by Amy L. Throckmorton, Jugal Y. Kapadia, James P. Carr, Chelsea M. Powell, Ryan D. Tate, Donald V. Traynham


  • Interaction of an Idealized Cavopulmonary Circulation With Mechanical Circulatory Assist Using an Intravascular Rotary Blood Pump

    by Sonya S. Bhavsar, William B. Moskowitz, Amy L. Throckmorton

    This study evaluated the performance of an intravascular, percutaneously-inserted, axial flow blood pump in an idealized total cavopulmonary connection (TCPC) model of a Fontan physiology. This blood pump, intended for placement in the inferior vena cava (IVC), is designed to augment pressure and blood flow from the IVC to the pulmonary circulation. Three different computational models were examined: (i) an idealized TCPC without a pump; (ii) an idealized TCPC with an impeller pump; and (iii) an idealized TCPC with an impeller and diffuser pump. Computational fluid dynamics analyses of these models were performed to assess the hydraulic performance of each model under varying physiologic conditions. Pressure-flow characteristics, fluid streamlines, energy augmentation calculations, and blood damage analyses were evaluated. Numerical predictions indicate that the pump with an impeller and diffuser blade set produces pressure generations of 1 to 16 mm Hg for rotational speeds of 2000 to 6000 rpm and flow rates of 1 to 4 L/min. In contrast, for the same flow range, the model with the impeller only in the IVC demonstrated pressure generations of 1 to 9 mm Hg at rotational speeds of 10 000 to 12 000 rpm. Influence of blood viscosity was found to be insignificant at low rotational speeds with minimal performance deviation at higher rotational speeds. Results from the blood damage index analyses indicate a low probability for damage with maximum damage index levels less than 1% and maximum fluid residence times below 0.6 s. The numerical predictions further indicated successful energy augmentation of the TCPC with a pump in the IVC. These results support the continued design and development of this cavopulmonary assist device.