Midterm outcome of fourth-generation ceramic-on-ceramic bearing surfaces in revision total hip arthroplasty
Authors:
Open Access
- 1 May 2018
- journal article
- research article
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 26 (2)
Abstract
Purpose: The purpose of this study is to evaluate the clinical and radiologic outcomes after revision total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) bearing surfaces. Methods: A total of 52 revision THAs (28 men and 19 women) using the fourth-generation CoC bearing surfaces were retrospectively evaluated. Both acetabular cup and femoral stem were revised in all cases. The mean follow-up period was 7.3 years (range, 4.0–9.9 years). The clinical results with Harris hip score (HHS), Western Ontario McMaster Osteoarthritis Index (WOMAC), and radiologic outcomes were evaluated. Results: At the final follow-up examination, the average HHS was 90.4 (range, 67–100). The average WOMAC pain and physical function score were 2.8 (range, 0–12) and 16.4 (range, 0–42), respectively. Complications were observed in 10 hips (19.2%). However, there were no bearing surface-related complications, and no cases of dislocation and squeaking. Retroacetabular pelvic osteolysis without cup loosening was observed in one hip at the final follow-up. However, no hip showed radiographic signs of cup loosening, vertical or horizontal acetabular cup migrations, and changes of inclinations during the follow-up period. Conclusion: Our data showed that clinical and radiologic outcomes after revision THA using fourth-generation CoC bearing were favorable. Hence, revision THA with the use of CoC bearing surfaces can be preferentially considered. Further studies with long-term follow-up data are warranted.Keywords
This publication has 37 references indexed in Scilit:
- Fracture of Ceramic Bearing Surfaces following Total Hip Replacement: A Systematic ReviewBioMed Research International, 2013
- Risk Factors for Ceramic Liner Fracture after Total Hip ArthroplastyHIP International, 2012
- Large-diameter Delta Ceramic-on-ceramic Versus Common-sized Ceramic-on-polyethylene Bearings in THAOrthopedics, 2012
- High Rate of Ceramic Sandwich Liner FractureClinical Orthopaedics and Related Research, 2012
- Fractures of a sandwich ceramic liner at ten year follow-upInternational Orthopaedics, 2011
- A Squeaky Reputation: The Problem May Be Design-dependentClinical Orthopaedics and Related Research, 2011
- Mathematical evaluation of jumping distance in total hip arthroplastyActa Orthopaedica, 2009
- Auswirkungen von klinisch relevanten Aluminium Keramik-, Zirkonium Keramik- und Titanpartikel unterschiedlicher Größe und Konzentration auf die TNFα-Ausschüttung in einem humanen Makrophagensystem / Effects of clinically relevant alumina ceramic particles, circonia ceramic particles and titanium particles of different sizes and concentrations on TNFα release in a human monocytic cell lineBiomedical Engineering / Biomedizinische Technik, 2004
- Alumina hip joints characterized by run‐in wear and steady‐state wear to 14 million cycles in hip‐simulator modelJournal of Biomedical Materials Research Part A, 2004