Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Hydrophobic IOLs
Authors:
- 1 December 2020
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (12) , 804-810
Abstract
PURPOSE: To measure the in vivo longitudinal chromatic aberration (LCA) from the chromatic difference of focus (480 to 700 nm) using psychophysical methods in patients bilaterally implanted with a hydrophobic trifocal intraocular lens (IOL). METHODS: Psychophysical best focus was measured in both eyes at different wavelengths (480 to 700 nm) and at three different viewing distances (0.00, +1.75, and +3.50 diopters [D]) using a custom-developed polychromatic adaptive optics set-up provided with a supercontinuum laser, a Hartmann-Shack wavefront sensor, a deformable mirror, a motorized Badal system, a pupil monitoring system, and a psychophysical channel with monochromatically illuminated stimuli. Measurements were performed on 10 patients (20 eyes) bilaterally implanted with hydrophobic trifocal diffractive IOLs (FineVisionHP POD F GF; PhysIOL). LCA was computed from the chromatic difference of focus curves as the difference between 480 and 700 nm at near, intermediate, and far. RESULTS: The LCA from psychophysical measurements was significantly higher for far vision (0.99 ± 0.06 diopters [D]), than for intermediate (0.67 ± 0.10 D) and near (0.23 ± 0.08 D) vision (one-way analysis of variance, P < .05). CONCLUSIONS: LCA for far vision was significantly higher than for intermediate and near vision in hydrophobic trifocal diffractive IOLs, in agreement with a previous study with the same optical design but hydrophilic material IOLs. The LCA for the hydro-phobic IOL is slightly higher than for the hydrophilic IOL at far. Different combinations of refractive and diffractive LCA will allow optimizing IOL designs to improve polychromatic image quality. [J Refract Surg. 2020;36(12):804–810.]Keywords
This publication has 31 references indexed in Scilit:
- Control of accommodation by longitudinal chromatic aberration and blue conesJournal of Vision, 2012
- Design and qualification of a diffractive trifocal optical profile for intraocular lensesJournal of Cataract & Refractive Surgery, 2011
- Energy Distribution between Distance and Near Images in Apodized Diffractive Multifocal Intraocular LensesInvestigative Ophthalmology & Visual Science, 2011
- Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench systemJournal of Cataract & Refractive Surgery, 2011
- Performance of presbyopia-correcting intraocular lenses in distance optical bench testsJournal of Cataract & Refractive Surgery, 2009
- The effect of chromatic dispersion on pseudophakic optical performanceBritish Journal of Ophthalmology, 2007
- History and development of the apodized diffractive intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Effect of Ocular Chromatic Aberration on Monocular Visual PerformanceOptometry and Vision Science, 1991
- ChromoretinoscopyVision Research, 1978
- Axial Chromatic Aberration of the Human EyeJournal of the Optical Society of America, 1957