Caliper measurements of femoral resection thickness in kinematic alignment total knee arthroplasty are accurate and reproducible
Authors:
Open Access
- 1 October 2025
- journal article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4)
Abstract
Purpose: To resurface the patient's knee to the prearthritic state in caliper‐verified kinematic alignment (KA) total knee arthroplasty, the thickness of femoral resections after adjusting for saw blade kerf and wear should equal the femoral component. The primary objective was to determine accuracy of caliper measurement by quantifying the systematic (i.e., bias) and random (i.e., precision) errors of both unworn and worn articular surfaces from varus and valgus knees. The secondary objective was to assess reproducibility. Methods: In this diagnostic test study, thickness of each femoral resection from the first patients with 20 varus knees and the first patients with 20 valgus knees was measured by the surgeon using a caliper with 10 mm wide jaws. Subsequently, an optical method established the gold standard thickness. From the difference between caliper and optical measurements, the mean error (bias) and the standard deviation of the error (precision) were computed. Three observers measured resection thickness in three trials on both worn and unworn surfaces for 12 patients with varus knees. Repeatability and reproducibility were assessed by computing the variance components from a two‐factor analysis of variance and corresponding intraclass correlation coefficient (ICC) values. Results: For worn and unworn surfaces from both varus and valgus knees, the bias was negligible and the precision was less than or equal to the 0.5 mm resolution of the caliper. For worn and unworn surfaces from varus knees, ICC values were > 0.95 for both repeatability and reproducibility. Conclusions: The caliper used in this study is a sufficiently accurate tool for measuring resection thickness intraoperatively on worn and unworn femoral articular surfaces regardless of knee deformity. The error is less than the resolution of the caliper and the reproducibility is high thus giving surgeons confidence that the native limb and joint lines will be restored provided that the measured resection thickness after correcting for sawblade kerf and wear equals the femoral component thickness to within ±0.5 mm. Level of Evidence: N/A.Keywords
This publication has 33 references indexed in Scilit:
- Correction of axial and rotational alignment after medial and lateral releases during balanced gap TKAActa Orthopaedica, 2010
- Results of an Initial Experience With Custom-fit Positioning Total Knee Arthroplasty in a Series of 48 PatientsOrthopedics, 2008
- Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variablesUltrasound in Obstetrics & Gynecology, 2008
- Three-Dimensional Mechanics, Kinematics, and Morphology of the Knee Viewed in Virtual RealityJournal of Bone and Joint Surgery, 2005
- The Functional Flexion-Extension Axis of the Knee Corresponds to the Surgical Epicondylar AxisThe Journal of Arthroplasty, 2005
- Does the femur roll-back with flexion?The Journal of Bone and Joint Surgery. British volume, 2004
- Accuracy of soft tissue balancing in total knee arthroplastyThe Journal of Arthroplasty, 2000
- Functional Medial Ligament Balancing in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2000
- Assessing Reproducibility by the Within-Subject Coefficient of Variation with Random Effects Models1996
- The Axes of Rotation of the KneeClinical Orthopaedics and Related Research, 1993