Evaluation of the reliability of MS1‐based approach to profile naturally occurring peptides with clinical relevance in urine samples
Authors:
- 22 August 2022
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 39 (S1) , e9369
Abstract
Rationale: The profiling of natural urinary peptides is a valuable indicator of kidney condition. While front‐end separation limits the speed of peptidomic profiling, MS1‐based results suffer from limited peptide coverage and specificity. Clinical studies on chronic kidney disease require an effective strategy to balance the trade‐off between identification depth and throughput. Methods: CKD273, a urinary proteome classifier associated with chronic kidney disease, in samples from diabetic nephropathy patients was profiled in parallel using capillary electrophoresis–mass spectrometry (CE–MS), liquid chromatography with mass spectrometry (LC–MS), and matrix‐assisted laser desorption/ionization–mass spectrometry (MALDI‐MS). Through cross‐comparison of results from MS1 of unfractionated peptides and elution‐time‐resolved MS1 as well as MS/MS in LC– and CE–MS approaches, we evaluated the contribution of false‐positive identification to MS1‐based identification and quantitation, and analyzed the benefit of front‐end separation in terms of accuracy and efficiency. Results: In LC– and CE–MS, although MS1 data resulted in higher number of identifications than MS/MS, elution‐time‐dependent analysis revealed extensive interference by non‐CKD273 peptides, which would contribute up to 50% to quantitation if they are not separated from genuine CKD273 peptides. In the absence of separation, MS1 data resulted in lower numbers of identifications and abundance pattern that significantly deviated from those by liquid chromatography with tandem mass spectrometry (LC–MS/MS) or capillary electrophoresis with tandem mass spectrometry (CE–MS/MS). CE showed higher identification efficiency even when less sample was used or achieved faster separation. Conclusions: To ensure the reliability of MS1‐based urinary peptide profiling, front‐end separation should not be omitted, and elution time should be used in addition to intact mass for identification. Including MS/MS in data acquisition does not compromise the speed or identification number, while benefiting data reliability by providing real‐time sequence verification.Keywords
Funding Information
- National Natural Science Foundation of China (21974069, 81974103)
This publication has 21 references indexed in Scilit:
- Urine Collagen Fragments and CKD Progression—The Cardiovascular Health StudyJournal of the American Society of Nephrology, 2015
- State‐of‐the‐art nanoplatform‐integrated MALDI‐MS impacting resolutions in urinary proteomicsProteomics – Clinical Applications, 2015
- Comparison of CE‐MS/MS and LC‐MS/MS sequencing demonstrates significant complementarity in natural peptide identification in human urineElectrophoresis, 2013
- A cross-platform toolkit for mass spectrometry and proteomicsNature Biotechnology, 2012
- A comparison between MALDI-MS and CE-MS data for biomarker assessment in chronic kidney diseasesJournal of Proteomics, 2012
- Naturally Occurring Human Urinary Peptides for Use in Diagnosis of Chronic Kidney DiseaseMolecular & Cellular Proteomics, 2010
- Simplified capillary electrophoresis nanospray sheath‐flow interface for high efficiency and sensitive peptide analysisRapid Communications in Mass Spectrometry, 2010
- Matrix‐free laser desorption/ionization mass spectrometry using silicon glancing angle deposition (GLAD) filmsRapid Communications in Mass Spectrometry, 2010
- Reproducibility of serum protein profiling by systematic assessment using solid‐phase extraction and matrix‐assisted laser desorption/ionization mass spectrometryRapid Communications in Mass Spectrometry, 2008
- Large‐scale protein identification of human urine proteome by multi‐dimensional LC and MS/MSProteomics – Clinical Applications, 2007