LZLingpeng Zhan

Lingpeng Zhan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lingpeng Zhan has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Conformational Dynamics-Driven Engineering of Nanobody Biosensor for Enhanced Detection of Ochratoxin A

    by Shaowen Wu, Jintao Xu, Lingpeng Zhan, Hualian Mo, Rulei Li, Wenjie Huang, Yarong Zhao, Yanyi Huang, Guanbo Wang, Shijuan Yan

    Nanobodies are promising recognition elements for food safety biosensors, yet the relationship between their conformational dynamics and ligand binding remains poorly understood. This study presents an integrated computational–experimental framework to elucidate conformational dynamics-function relationships and guide the engineering of nanobody-based detection systems for ochratoxin A (OTA), a prevalent mycotoxin in agricultural commodities. Using the anti-OTA nanobody NB28, we employed molecular dynamics simulations, ion mobility-mass spectrometry, and collision-induced unfolding assays to investigate the ligand recognition mechanisms. NB28 binds OTA through a tunnel-like mechanism, inducing pronounced conformational shifts toward extended states, validated experimentally through collision cross-sectional measurements and unfolding profiles. Leveraging these dynamic insights, we engineered a T80C variant exhibiting ∼1.8-fold enhanced detection sensitivity with reduced IC50 values while preserving specificity. T80C demonstrated robust performance across cereal matrices, achieving detection limits well below the EU regulatory threshold of 5 μg/kg. This dynamics-driven approach provides a generalizable strategy for food safety biosensor development.


  • Enhancing MALDI-MSI spatial proteomics analysis through matrix solution acidification

    by Gaofeng Ji, Li Yi, Kunyue Deng, Peiqi Luo, Lingpeng Zhan

    A simple matrix acidification strategy enhances MALDI-MSI of intact proteins and digested peptides.


  • Open Access

    Deepening imaging-based spatial proteomics at high spatial resolution through controlled tissue resizing and in-situ bottom-up mass spectrometry

    by Kunyue Deng, Lingpeng Zhan, Li Yi, Jingpeng Zhang, Mingchuan Tang, Tianyi Chang, Gaofeng Ji, Xinyang Shao, Xiang Xu, Xiaoyun Wei, et al.

    Understanding the spatial organization of proteins in tissues is essential for elucidating biological function, but current proteomic imaging methods face limitations in resolution, sensitivity, and multiplexing capability. Here, we present IMPACT (Imaging Mass Spectrometry for Proteome Analysis on Compressed Tissue), a hydrogel-based workflow that integrates controlled vertical tissue compression following expansion to enhance protein detection while improving spatial resolution in mass spectrometry imaging (MSI). Through a 6-fold lateral expansion and 100-fold thickness reduction, analytes were concentrated at the surface to improve detection and enable analysis of thick specimen. Coupled with optimized in-gel digestion using hybrid enzymes, IMPACT increased protein identifications 3-fold compared to conventional MSI while maintaining spatial fidelity. We demonstrate IMPACT’s utility in mapping low-abundance proteins and resolving fine anatomical structures. Orthogonal validation with immunofluorescence and integration with spatial transcriptomics further reveal protein-RNA distribution discrepancies, highlighting the need for direct proteomic imaging. IMPACT bridges critical gaps in spatial proteomics by enabling high-resolution, high-sensitivity, and multiplexed untargeted protein imaging, opening new avenues for tissue biology and biomarker discovery.

  • Open Access

    Precise mycobacterial species and subspecies identification using the PEP-TORCH peptidome algorithm

    by Duran Bao, Sudipa Maity, Lingpeng Zhan, Seungyeon Seo, Qingbo Shu, Christopher J Lyon, Bo Ning, Adrian Zelazny, Tony Y Hu, Jia Fan

    Mycobacterial infections pose a significant global health concern, requiring precise identification for effective treatment. However, diagnosing them is challenging due to inaccurate identifications and prolonged times. In this study, we aimed to develop a novel peptidome-based method using mycobacterial growth indicator tube (MGIT) cultures for faster and more accurate identification. We created the PEPtide Taxonomy/ORganism CHecking (PEP-TORCH), an algorithm that analyzes tryptic peptides identified by mass spectrometry to diagnose species and subspecies with predominance scores. PEP-TORCH demonstrated 100% accuracy in identifying mycobacterial species, subspecies, and co-infections in 81 individuals suspected of mycobacterial infections, eliminating the need for a sub-solid culture procedure, the gold standard in clinical practice. A notable strength of PEP-TORCH is its ability to provide information on species and subspecies simultaneously, a process conventionally achieved sequentially. This capability significantly expedites pathogen identification. Furthermore, a targeted proteomics method was validated in 63 clinical samples using the taxa-specific peptides selected by PEP-TORCH, making them suitable as biomarkers in more clinically friendly settings. This comprehensive identification approach holds promise for streamlining treatment strategies in clinical practice.


  • B4C‐Assisted Paper Spray Ionization Mass Spectrometry

    by Dimei Hu, Lulu Yu, Zijian Wei, Lingpeng Zhan, Peiqi Luo

    A novel inorganic nonmetallic material boron carbide (B4C) was applied in paper spray ionization to analyze organic molecules in both negative and positive modes. The utilization of B4C has led to a notable enhancement in signal responses for various molecules, including bisphenols and drugs, by approximately two to four times. The limit of detection (LOD) of bisphenol AF and nilotinib standard solutions can reach 1 and 0.5 μg/mL, respectively. Moreover, linear relationships for bisphenol AF was established within the concentration range of 1–100 μg/mL, exhibiting strong correlation coefficients. Recovery experiments for BPAF in water samples from the inlet and outlet of a sewage treatment plant, conducted without any pretreatment, achieved a maximum recovery rate of 98.8% and an RSD below 9.78%.


  • Multi‐modal mass spectrometry imaging of a single tissue section

    by Lingpeng Zhan, Yanyi Huang, Guanbo Wang

    Mass spectrometry imaging (MSI) was developed to visualize spatial chemical information within tissues, thereby facilitating spatial multi‐omic analysis. However, due to the limited spatial information provided by individual modal MSI, correlating various chemical data within tissues remains a significant challenge. In recent years, multimodal MSI has garnered considerable attention due to its ability to visualize the spatial distributions of multiple biomolecules within tissues. Among the strategies employed in this field, multimodal imaging on a single tissue section circumvents multiple issues introduced by integration of images of consecutive tissue sections. In this minireview, we provide an overview of multimodal MSI on a single tissue section, with a particular focus on the use of Matrix‐Assisted Laser Desorption/Ionization–MSI for spatial multi‐omic investigations that offer a comprehensive and in‐depth elucidation of the biological state and activities, aiming to inspire the development of new approaches in this field.


  • Tracking the disulfide rearrangement of heated lactoglobulin by matrix‐assisted laser desorption/ionization‐in‐source decay top‐down analysis

    by Xiaoyun Wei, Peiqi Luo, Lingpeng Zhan

    Disulfide bond rearrangement is a common occurrence during protein analysis or treatment. A convenient and rapid method has been developed to investigate heat‐induced disulfide rearrangement of lactoglobulin using matrix‐assisted laser desorption/ionization‐in‐source decay (MALDI‐ISD) technology. By analyzing heated lactoglobulin in reflectron and linear mode, we demonstrated that cysteines C66 and C160 exist as free residues other than linked ones in some protein isomers. This method provides a straightforward and expeditious way to assess the cysteine status and structural changes of proteins under heat stress.


  • Evaluation of the reliability of MS1‐based approach to profile naturally occurring peptides with clinical relevance in urine samples

    by Jialu Jiang, Lingpeng Zhan, Liuyan Dai, Xiaopeng Yao, Yao Qin, Zhongqin Zhu, Mei Zhang, Wenjun Tong, Guanbo Wang

    Rationale: The profiling of natural urinary peptides is a valuable indicator of kidney condition. While front‐end separation limits the speed of peptidomic profiling, MS1‐based results suffer from limited peptide coverage and specificity. Clinical studies on chronic kidney disease require an effective strategy to balance the trade‐off between identification depth and throughput. Methods: CKD273, a urinary proteome classifier associated with chronic kidney disease, in samples from diabetic nephropathy patients was profiled in parallel using capillary electrophoresis–mass spectrometry (CE–MS), liquid chromatography with mass spectrometry (LC–MS), and matrix‐assisted laser desorption/ionization–mass spectrometry (MALDI‐MS). Through cross‐comparison of results from MS1 of unfractionated peptides and elution‐time‐resolved MS1 as well as MS/MS in LC– and CE–MS approaches, we evaluated the contribution of false‐positive identification to MS1‐based identification and quantitation, and analyzed the benefit of front‐end separation in terms of accuracy and efficiency. Results: In LC– and CE–MS, although MS1 data resulted in higher number of identifications than MS/MS, elution‐time‐dependent analysis revealed extensive interference by non‐CKD273 peptides, which would contribute up to 50% to quantitation if they are not separated from genuine CKD273 peptides. In the absence of separation, MS1 data resulted in lower numbers of identifications and abundance pattern that significantly deviated from those by liquid chromatography with tandem mass spectrometry (LC–MS/MS) or capillary electrophoresis with tandem mass spectrometry (CE–MS/MS). CE showed higher identification efficiency even when less sample was used or achieved faster separation. Conclusions: To ensure the reliability of MS1‐based urinary peptide profiling, front‐end separation should not be omitted, and elution time should be used in addition to intact mass for identification. Including MS/MS in data acquisition does not compromise the speed or identification number, while benefiting data reliability by providing real‐time sequence verification.


  • MALDI-TOF/TOF tandem mass spectrometry imaging reveals non-uniform distribution of disaccharide isomers in plant tissues

    by Lingpeng Zhan, Xi Huang, Jinjuan Xue, Huihui Liu, Caiqiao Xiong, Jiyun Wang, Zongxiu Nie


  • Open Access

    MALDI-TOF/TOF Tandem Mass Spectrometry Imaging Reveals Non-uniform Distribution of Disaccharide Isomers in Plant Tissues

    by Lingpeng Zhan, Xi Huang, Jinjuan Xue, Huihui Liu, Caiqiao Xiong, Jiyun Wang, Zongxiu Nie

    Mass spectrometry imaging (MSI) has been increasingly utilized in investigating the locations of biomolecules within tissues. However, the isomeric compounds are rarely distinguished in the MS images, due to inability of MSI methods to differentiate isomers in the probing area. Coupling tandem mass spectrometry with MSI can facilitate differentiating isomeric compounds in ion images. Here we apply MALDI-TOF/TOF tandem mass spectrometry imaging approach to revealing the spatial distributions of isomeric disaccharides in plant tissues. First, the MS/MS imaging analysis of disaccharide-matrix droplet spots demonstrated the feasibility of distinguishing isomeric species in tissues, by measuring the relative intensity of specific fragments. Then, we conducted tandem MS imaging of disaccharides in onion bulb tissues, which indicated that sucrose and other unknown non-sucrose disaccharides exhibit heterogeneous locations throughout the tissues. This method enables us to image disaccharide isomers differentially in biological tissues, and to discover new saccharide species in plant. This work also emphasizes the necessity of considering isobaric compounds when interpreting MSI results.