Abstract
In the first part of this article the electronic automatic system for the measurements of dynamic breakdown voltages Ub with linearly rising (ramp) pulses is presented. It generates the sequence of ramp pulses with subvoltage level Usub≈0 during the relaxation time τ of the tube, and the ramp pulses start from the static breakdown voltage Us , thus enabling the correct study of electrical breakdowns and relaxation in gases. In the second part the measurements in argon with and without a voltage during the off period of the pulse are analyzed. The influence of the subvoltage on the mean value of the breakdown voltage Ub¯ as a function of the rise rate k , on the statistical Ub distributions and on the afterglow kinetics is also discussed.