Abstract
To study the use of serial ultrasound gastric residual volume (GRV) measurements in predicting feed intolerance in critically ill patients. This study was conducted in various intensive care units (ICUs) of All India Institute of Medical Sciences, New Delhi. Forty-three critically ill patients aged more than 18 years were studied for a total of 130 enteral feeding days. Gastric residual volume was obtained by calculating the antral cross-sectional area (CSA), which is the product of anteroposterior (AP) and craniocaudal (CC) diameters of gastric antrum obtained using ultrasound in the right lateral decubitus position. A baseline measurement was done before the initiation of the enteral feed and termed GRV0, the ultrasound scanning was repeated every 1 hour for the first 4 hours and termed GRV1, GRV2, GRV3, and GRV4, respectively, and the patients were watched for feed intolerance. The receiver operating characteristic (ROC) curves were constructed to correlate the GRV at each time with feed intolerance. The data from 43 medical and surgical critically ill patients were analyzed. Out of 130 feeding days, 13 were noted to be feed intolerant. Gastric residual volume at the end of the fourth hour of feed, that is, GRV4 was the best predictor of feed intolerance with 99.3% area under the curve (AUROC), sensitivity of 99%, specificity of 99.3%, and 95% CI, 0.89–0.98 followed by GRV3, with AUROC of 96% and sensitivity and specificity of 92.3 and 96%, respectively, with 95% CI, 0.92–0.99. Ankalagi B, Singh PM, Rewari V, Ramachandran R, Aggarwal R, Soni KD, et al. Serial Ultrasonographic-measurement of Gastric Residual Volume in Critically Ill Patients for Prediction of Gastric Tube Feed Intolerance. Indian J Crit Care Med 2022;26(9):987–992.Keywords
This publication has 16 references indexed in Scilit:
- Intra- and Interrater Reliability of Ultrasound Assessment of Gastric VolumeAnesthesiology, 2014
- Ultrasound assessment of gastric volume in critically ill patientsIntensive Care Medicine, 2014
- Anesthesiologists’ learning curves for bedside qualitative ultrasound assessment of gastric content: a cohort studyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2013
- Validation of a Mathematical Model for Ultrasound Assessment of Gastric Volume by Gastroscopic ExaminationAnesthesia & Analgesia, 2013
- Epidemiologie, Diagnostik und Therapie erwachsener Patienten mit nosokomialer PneumoniePneumologie, 2012
- Impact of disease severity on gastric residual volume in critical patientsWorld Journal of Gastroenterology, 2011
- Methods for the Assessment of Gastric Emptying in Critically Ill, Enterally Fed AdultsNutrition in Clinical Practice, 2009
- North American Summit on Aspiration in the Critically Ill Patient: Consensus StatementJournal of Parenteral and Enteral Nutrition, 2002
- Scintigraphic measurement of gastric emptying and ultrasonographic assessment of antral area: relation to appetite.Gut, 1996
- Reliability and interobserver variability of ultrasonographic measurement of gastric emptying rateDigestive Diseases and Sciences, 1993