DARCS: Memory-Efficient Deep Compressed Sensing Reconstruction for Acceleration of 3D Whole-Heart Coronary MR Angiography
- 1 January 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2105-2119
Abstract
Three-dimensional coronary magnetic resonance angiography (CMRA) requires reconstruction algorithms that can significantly suppress the artifacts encountered in heavily undersampled acquisitions. While unrolling-based deep reconstruction methods have achieved state-of-the-art performance on 2D image reconstruction, their application in 3D reconstruction is hindered by the large amount of memory required to train an unrolled network. In this study, we propose a memoryefficient deep compressed sensing method that employs a sparsifying transform based on a pre-trained artifact estimation network. The artifact image estimated by a welltrained network is expected to be sparse when the input image is artifact-free and less sparse when the input image has artifacts. Thus, the artifact estimation network can be used as an inherent sparsifying transform. The proposed method, De-Aliasing Regularization-based Compressed Sensing (DARCS), was compared with a patch-based lowrank method, de-aliasing generative adversarial network (DAGAN), 3D model-based deep learning (MoDL), plug-and-play, and AI-assisted compressed sensing (AI-CS) in terms of 3D CMRA acceleration. The results demonstrate that DARCS surpasses the reconstruction quality of the comparison methods, by approximately 2 dB in peak signal-to-noise ratio (PSNR). Furthermore, the proposed method generalizes well to different undersampling rates, patterns, and noise levels, with a memory usage of only 63% of that needed by 3D MoDL. In conclusion, DARCS improves reconstruction quality for 3D CMRA with reduced memory burden.Keywords
All Related Versions
Funding Information
- National Key Research and Development Program of China (2024YFF0509200)
- National Natural Science Foundation of China (62001288)
- Shanghai Science and Technology Commission (22TS1400200)
This publication has 72 references indexed in Scilit:
- Clinical Application of Non‐Contrast‐Enhanced Dixon Water‐Fat Separation Compressed SENSE Whole‐Heart Coronary MR Angiography at 3.0 T With and Without NitroglycerinJournal of Magnetic Resonance Imaging, 2021
- 5D whole‐heart sparse MRIMagnetic Resonance in Medicine, 2017
- Four-dimensional respiratory motion-resolved whole heart coronary MR angiographyMagnetic Resonance in Medicine, 2016
- XD‐GRASP: Golden‐angle radial MRI with reconstruction of extra motion‐state dimensions using compressed sensingMagnetic Resonance in Medicine, 2015
- ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPAMagnetic Resonance in Medicine, 2013
- Coil compression for accelerated imaging with Cartesian samplingMagnetic Resonance in Medicine, 2012
- Low‐dimensional‐structure self‐learning and thresholding: Regularization beyond compressed sensing for MRI ReconstructionMagnetic Resonance in Medicine, 2011
- Two‐point dixon method with flexible echo timesMagnetic Resonance in Medicine, 2010
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraintMagnetic Resonance in Medicine, 2007