Fan Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fan Yang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Chenxi Hu
National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Hang Jin
Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Institute of Medical Imaging, Shanghai, 200032, PR China; Department of Radiology, Shanghai Geriatric Medical Center and Zhongshan Hospital Minhang Campus, Shanghai, 201104, PR China
2 shared publications - Jie Li
Shanghai Jiao Tong University, Shanghai, China
2 shared publications Juan Gao
National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications- Zhihao Xue
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Zhuo Chen
National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications
Latest Publications
- Open Access
- 11 April 2025
- Published by Association for the Advancement of Artificial Intelligence (AAAI) in Proceedings of the AAAI Conference on Artificial Intelligence
- Vol. 39 (2) , 2114-2122
Contrasting Adversarial Perturbations: The Space of Harmless Perturbations
Existing works have extensively studied adversarial examples, which are minimal perturbations that can mislead the output of deep neural networks (DNNs) while remaining imperceptible to humans. However, in this work, we reveal the existence of a harmless perturbation space, in which perturbations drawn from this space, regardless of their magnitudes, leave the network output unchanged when applied to inputs. Essentially, the harmless perturbation space emerges from the usage of non-injective functions (linear or non-linear layers) within DNNs, enabling multiple distinct inputs to be mapped to the same output. For linear layers with input dimensions exceeding output dimensions, any linear combination of the orthogonal bases of the nullspace of the parameter consistently yields no change in their output. For non-linear layers, the harmless perturbation space may expand, depending on the properties of the layers and input samples. Inspired by this property of DNNs, we solve for a family of general perturbation spaces that are redundant for the DNN's decision, and can be used to hide sensitive data and serve as a means of model identification. Our work highlights the distinctive robustness of DNNs (i.e., consistency under large magnitude perturbations) in contrast to adversarial examples (vulnerability for small noises).
- 11 April 2025
- Published by Association for the Advancement of Artificial Intelligence (AAAI) in Proceedings of the AAAI Conference on Artificial Intelligence
- Vol. 39 (2) , 2114-2122
Open AccessContrasting Adversarial Perturbations: The Space of Harmless Perturbations
Existing works have extensively studied adversarial examples, which are minimal perturbations that can mislead the output of deep neural networks (DNNs) while remaining imperceptible to humans. However, in this work, we reveal the existence of a harmless perturbation space, in which perturbations drawn from this space, regardless of their magnitudes, leave the network output unchanged when applied to inputs. Essentially, the harmless perturbation space emerges from the usage of non-injective functions (linear or non-linear layers) within DNNs, enabling multiple distinct inputs to be mapped to the same output. For linear layers with input dimensions exceeding output dimensions, any linear combination of the orthogonal bases of the nullspace of the parameter consistently yields no change in their output. For non-linear layers, the harmless perturbation space may expand, depending on the properties of the layers and input samples. Inspired by this property of DNNs, we solve for a family of general perturbation spaces that are redundant for the DNN's decision, and can be used to hide sensitive data and serve as a means of model identification. Our work highlights the distinctive robustness of DNNs (i.e., consistency under large magnitude perturbations) in contrast to adversarial examples (vulnerability for small noises).
- Open Access
- 26 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2535
A Novel Approach to Incremental Diffusion for Continuous Dataset Updates in Image Retrieval
Diffusion is well known for its success in improving retrieval performance by exploiting the local structure of data distribution. Some recent works have focused on improving its efficiency by shifting the computing burden offline. However, we find that efficient offline diffusion handles continuously updating datasets with difficulty, which directly hinders its application in the real world. Unlike previous methods that apply diffusion to the entire gallery, we introduce an anchor graph to serve as an agent of the complete gallery graph. By doing that, we empower diffusion with the ability of retrieving newly added images at acceptable computational cost. We demonstrate that our proposed method is a good approximation of diffusion featuring fast online search speed and the ability of handling growing data. Moreover, experiments on benchmark datasets show that the proposed method outperforms the state of the art by a large margin with proper parameter settings.
- 26 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2535
Open AccessA Novel Approach to Incremental Diffusion for Continuous Dataset Updates in Image Retrieval
Diffusion is well known for its success in improving retrieval performance by exploiting the local structure of data distribution. Some recent works have focused on improving its efficiency by shifting the computing burden offline. However, we find that efficient offline diffusion handles continuously updating datasets with difficulty, which directly hinders its application in the real world. Unlike previous methods that apply diffusion to the entire gallery, we introduce an anchor graph to serve as an agent of the complete gallery graph. By doing that, we empower diffusion with the ability of retrieving newly added images at acceptable computational cost. We demonstrate that our proposed method is a good approximation of diffusion featuring fast online search speed and the ability of handling growing data. Moreover, experiments on benchmark datasets show that the proposed method outperforms the state of the art by a large margin with proper parameter settings.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2105-2119
DARCS: Memory-Efficient Deep Compressed Sensing Reconstruction for Acceleration of 3D Whole-Heart Coronary MR Angiography
Three-dimensional coronary magnetic resonance angiography (CMRA) requires reconstruction algorithms that can significantly suppress the artifacts encountered in heavily undersampled acquisitions. While unrolling-based deep reconstruction methods have achieved state-of-the-art performance on 2D image reconstruction, their application in 3D reconstruction is hindered by the large amount of memory required to train an unrolled network. In this study, we propose a memoryefficient deep compressed sensing method that employs a sparsifying transform based on a pre-trained artifact estimation network. The artifact image estimated by a welltrained network is expected to be sparse when the input image is artifact-free and less sparse when the input image has artifacts. Thus, the artifact estimation network can be used as an inherent sparsifying transform. The proposed method, De-Aliasing Regularization-based Compressed Sensing (DARCS), was compared with a patch-based lowrank method, de-aliasing generative adversarial network (DAGAN), 3D model-based deep learning (MoDL), plug-and-play, and AI-assisted compressed sensing (AI-CS) in terms of 3D CMRA acceleration. The results demonstrate that DARCS surpasses the reconstruction quality of the comparison methods, by approximately 2 dB in peak signal-to-noise ratio (PSNR). Furthermore, the proposed method generalizes well to different undersampling rates, patterns, and noise levels, with a memory usage of only 63% of that needed by 3D MoDL. In conclusion, DARCS improves reconstruction quality for 3D CMRA with reduced memory burden.
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (5) , 2105-2119
DARCS: Memory-Efficient Deep Compressed Sensing Reconstruction for Acceleration of 3D Whole-Heart Coronary MR Angiography
Three-dimensional coronary magnetic resonance angiography (CMRA) requires reconstruction algorithms that can significantly suppress the artifacts encountered in heavily undersampled acquisitions. While unrolling-based deep reconstruction methods have achieved state-of-the-art performance on 2D image reconstruction, their application in 3D reconstruction is hindered by the large amount of memory required to train an unrolled network. In this study, we propose a memoryefficient deep compressed sensing method that employs a sparsifying transform based on a pre-trained artifact estimation network. The artifact image estimated by a welltrained network is expected to be sparse when the input image is artifact-free and less sparse when the input image has artifacts. Thus, the artifact estimation network can be used as an inherent sparsifying transform. The proposed method, De-Aliasing Regularization-based Compressed Sensing (DARCS), was compared with a patch-based lowrank method, de-aliasing generative adversarial network (DAGAN), 3D model-based deep learning (MoDL), plug-and-play, and AI-assisted compressed sensing (AI-CS) in terms of 3D CMRA acceleration. The results demonstrate that DARCS surpasses the reconstruction quality of the comparison methods, by approximately 2 dB in peak signal-to-noise ratio (PSNR). Furthermore, the proposed method generalizes well to different undersampling rates, patterns, and noise levels, with a memory usage of only 63% of that needed by 3D MoDL. In conclusion, DARCS improves reconstruction quality for 3D CMRA with reduced memory burden.
- 15 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1225-1236
Robust Fast Inter-Bin Image Registration for Undersampled Coronary MRI Based on a Learned Motion Prior
Objective: To propose a 3D nonrigid registration method that accurately estimates the 3D displacement field from artifact-corrupted Coronary Magnetic Resonance Angiography (CMRA) images. Methods: We developed a novel registration framework for registration of artifact-corrupted images based on a 3D U-Net initializer and a deep unrolling network. By leveraging a supervised learning framework with training labels estimated from fully-sampled images, the unrolling network learns a task-specific motion prior which reduces motion estimation biases caused by undersampling artifacts in the source images. We evaluated the proposed method, UNROLL, against an iterative Free-Form Deformation (FFD) registration method and a recently proposed Respiratory Motion Estimation network (RespME-net) for 6-fold (in-distribution) and 11-fold (out-of-distribution) accelerated CMRA. Results: Compared to the baseline methods, UNROLL improved both the accuracy of motion estimation and the quality of motion-compensated CMRA reconstruction at 6-fold acceleration. Furthermore, even at 11-fold acceleration, which was not included during training, UNROLL still generated more accurate displacement fields than the baseline methods. The computational time of UNROLL for the whole 3D volume was only 2 seconds. Conclusion: By incorporating a learned respiratory motion prior, the proposed method achieves highly accurate motion estimation despite the large acceleration. Significance: This work introduces a fast and accurate method to estimate the displacement field from low-quality source images. It has the potential to significantly improve the quality of motion-compensated reconstruction for highly accelerated 3D CMRA.
- 15 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (4) , 1225-1236
Robust Fast Inter-Bin Image Registration for Undersampled Coronary MRI Based on a Learned Motion Prior
Objective: To propose a 3D nonrigid registration method that accurately estimates the 3D displacement field from artifact-corrupted Coronary Magnetic Resonance Angiography (CMRA) images. Methods: We developed a novel registration framework for registration of artifact-corrupted images based on a 3D U-Net initializer and a deep unrolling network. By leveraging a supervised learning framework with training labels estimated from fully-sampled images, the unrolling network learns a task-specific motion prior which reduces motion estimation biases caused by undersampling artifacts in the source images. We evaluated the proposed method, UNROLL, against an iterative Free-Form Deformation (FFD) registration method and a recently proposed Respiratory Motion Estimation network (RespME-net) for 6-fold (in-distribution) and 11-fold (out-of-distribution) accelerated CMRA. Results: Compared to the baseline methods, UNROLL improved both the accuracy of motion estimation and the quality of motion-compensated CMRA reconstruction at 6-fold acceleration. Furthermore, even at 11-fold acceleration, which was not included during training, UNROLL still generated more accurate displacement fields than the baseline methods. The computational time of UNROLL for the whole 3D volume was only 2 seconds. Conclusion: By incorporating a learned respiratory motion prior, the proposed method achieves highly accurate motion estimation despite the large acceleration. Significance: This work introduces a fast and accurate method to estimate the displacement field from low-quality source images. It has the potential to significantly improve the quality of motion-compensated reconstruction for highly accelerated 3D CMRA.
- 29 May 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1380-1395
Regularized SUPER‐CAIPIRINHA: Accelerating 3D variable flip‐angle T1 mapping with accurate and efficient reconstruction
Purpose: To propose an acceleration method for 3D variable flip‐angle (VFA) T1 mapping based on a technique called shift undersampling improves parametric mapping efficiency and resolution (SUPER).Methods: The proposed method incorporates strategies of SUPER, controlled aliasing in volumetric parallel imaging (CAIPIRINHA), and total variation‐based regularization to accelerate 3D VFA T1 mapping. The k‐space sampling grid of CAIPIRINHA is internally undersampled with SUPER along the contrast dimension. A proximal algorithm was developed to preserve the computational efficiency of SUPER in the presence of regularization. The regularized SUPER‐CAIPIRINHA (rSUPER‐CAIPIRINHA) was compared with low rank plus sparsity (L + S), reconstruction of principal component coefficient maps (REPCOM), and other SUPER‐based methods via simulations and in vivo brain T1 mapping. The results were assessed quantitatively with NRMSE and structural similarity index measure (SSIM), and qualitatively by two experienced reviewers.Results: rSUPER‐CAIPIRINHA achieved a lower NRMSE and higher SSIM than L + S (0.11 ± 0.01 vs. 0.19 ± 0.03, p < 0.001; 0.66 ± 0.05 vs. 0.37 ± 0.03, p < 0.001) and REPCOM (0.16 ± 0.02, p < 0.001; 0.46 ± 0.04, p < 0.001). The reconstruction time of rSUPER‐CAIPIRINHA was 6% of L + S and 2% of REPCOM. For the qualitative comparison, rSUPER‐CAIPIRINHA showed improvement of overall image quality and reductions of artifacts and blurring, although with a lower apparent SNR. Compared with 2D SUPER‐SENSE, rSUPER‐CAIPIRINHA significantly reduced NRMSE (0.11 ± 0.01 vs. 0.23 ± 0.04, p < 0.001) and generated less noisy reconstructions.Conclusion: By incorporating SUPER, CAIPIRINHA, and regularization, rSUPER‐CAIPIRINHA mitigated noise amplification, reduced artifacts and blurring, and achieved faster reconstructions compared with L + S and REPCOM. These advantages render 3D rSUPER‐CAIPIRINHA VFA T1 mapping potentially useful for clinical applications.
- 29 May 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (4) , 1380-1395
Regularized SUPER‐CAIPIRINHA: Accelerating 3D variable flip‐angle T1 mapping with accurate and efficient reconstruction
Purpose: To propose an acceleration method for 3D variable flip‐angle (VFA) T1 mapping based on a technique called shift undersampling improves parametric mapping efficiency and resolution (SUPER).Methods: The proposed method incorporates strategies of SUPER, controlled aliasing in volumetric parallel imaging (CAIPIRINHA), and total variation‐based regularization to accelerate 3D VFA T1 mapping. The k‐space sampling grid of CAIPIRINHA is internally undersampled with SUPER along the contrast dimension. A proximal algorithm was developed to preserve the computational efficiency of SUPER in the presence of regularization. The regularized SUPER‐CAIPIRINHA (rSUPER‐CAIPIRINHA) was compared with low rank plus sparsity (L + S), reconstruction of principal component coefficient maps (REPCOM), and other SUPER‐based methods via simulations and in vivo brain T1 mapping. The results were assessed quantitatively with NRMSE and structural similarity index measure (SSIM), and qualitatively by two experienced reviewers.Results: rSUPER‐CAIPIRINHA achieved a lower NRMSE and higher SSIM than L + S (0.11 ± 0.01 vs. 0.19 ± 0.03, p < 0.001; 0.66 ± 0.05 vs. 0.37 ± 0.03, p < 0.001) and REPCOM (0.16 ± 0.02, p < 0.001; 0.46 ± 0.04, p < 0.001). The reconstruction time of rSUPER‐CAIPIRINHA was 6% of L + S and 2% of REPCOM. For the qualitative comparison, rSUPER‐CAIPIRINHA showed improvement of overall image quality and reductions of artifacts and blurring, although with a lower apparent SNR. Compared with 2D SUPER‐SENSE, rSUPER‐CAIPIRINHA significantly reduced NRMSE (0.11 ± 0.01 vs. 0.23 ± 0.04, p < 0.001) and generated less noisy reconstructions.Conclusion: By incorporating SUPER, CAIPIRINHA, and regularization, rSUPER‐CAIPIRINHA mitigated noise amplification, reduced artifacts and blurring, and achieved faster reconstructions compared with L + S and REPCOM. These advantages render 3D rSUPER‐CAIPIRINHA VFA T1 mapping potentially useful for clinical applications.