Effect of Serum on Electrochemical Detection of Bioassays Having Ag Nanoparticle Labels
Open Access
- 22 April 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 6 (5) , 1956-1962
Abstract
The effect of serum on electrochemical detection of bioassays having silver nanoparticle (AgNP) detection labels was investigated. Both a model assay and an antigen-specific sandwich bioassay for the heart failure marker NT-proBNP were examined. In both cases, the AgNP labels were conjugated to a detection antibody. Electrochemical detection was carried out using a galvanic exchange/anodic stripping voltammetry method in which Au3+ exchanges with AgNP labels. The assays were carried out using a paper-based electrode platform. The bioassays were exposed to different serum conditions prior to and during detection. There are three important outcomes reported in this article. First, both the model- and antigen-specific assays could be formed in undiluted serum with no detectable interferences from the serum components. Second, to achieve the maximum possible electrochemical signal, the highest percentage of serum that can remain in an assay buffer during electrochemical detection is 0.25% when no washing is performed. The assay results are rendered inaccurate when 0.50% or more of serum is present. Third, the factors inhibiting galvanic exchange in serum probably relate to surface adsorption of biomolecules onto the AgNP labels, chelation of Au3+ by serum components, or both. The results reported here provide general guidance for using metal NP labels for electrochemical assays in biofluids.Keywords
Funding Information
- Welch Foundation (F-0032)
- National Heart, Lung, and Blood Institute (R01HL137601)
This publication has 48 references indexed in Scilit:
- Electrochemical Biosensors Employing an Internal Electrode Attachment Site and Achieving Reversible, High Gain Detection of Specific Nucleic Acid SequencesAnalytical Chemistry, 2011
- Protein Detection Using Arrayed Microsensor Chips: Tuning Sensor Footprint to Achieve Ultrasensitive Readout of CA-125 in Serum and Whole BloodAnalytical Chemistry, 2011
- Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: a reviewLab on a Chip, 2011
- Antibody production, design and use for biosensor-based applicationsSeminars in Cell & Developmental Biology, 2009
- Electrochemical Glucose Sensors and Their Applications in Diabetes ManagementChemical Reviews, 2008
- Biosensors for clinical diagnostics industrySensors and Actuators B: Chemical, 2003
- The Rise and Fall of i-STAT Point-of-Care Blood Gas Testing in an Acute Care HospitalAmerican Journal of Clinical Pathology, 2000
- Control of Electron Transfer Kinetics at Glassy Carbon Electrodes by Specific Surface ModificationAnalytical Chemistry, 1996
- THE DISTRIBUTION AND CHEMICAL COMPOSITION OF ULTRACENTRIFUGALLY SEPARATED LIPOPROTEINS IN HUMAN SERUMJournal of Clinical Investigation, 1955