Impact of Degradation and Material Crystallinity on the Mechanical Performance of a Bioresorbable Polymeric Stent
Open Access
- 20 May 2021
- journal article
- research article
- Published by Springer Nature in Journal of Elasticity
- Vol. 145 (1-2) , 243-264
Abstract
Bioresorbable polymeric stents (BPS) offer possibilities to help address the long-term complications associated with permanent vascular implants, however in-vivo degradation behaviour is not yet fully understood. Here, finite element analysis (FEA) techniques based on physio-chemical reaction diffusion equations are used to predict and analyse BPS degradation behaviour. Physio-chemical degradation models for polymers, both amorphous and semi-crystalline, are incorporated into the FEA software package Abaqus/Standard allowing for BPS degradation rate predictions to be made, with a focus on poly-L-lactide (PLLA). The outputs of the degradation models are linked to mechanical behaviour via three different damage models which couple the changes in molecular weight and crystallinity with a hyperelastic constitutive model for PLLA mechanical behaviour. A simplified representation of a PLLA BPS in an artery is used as a demonstration case. The effects of applied degradation product diffusion boundary conditions on the molecular weight and crystallinity of PLLA BPS under simulated degradation are examined, and the impact of material heterogeneities and mechanical load boundary condition on the scaffolding performance and elastic properties of the degrading stent are investigated. The results suggest that the BPS performance are strongly dependent on the assumed boundary conditions, both in terms of degradation product diffusion and mechanical loading.Keywords
Funding Information
- College of Engineering and Informatics, National University of Ireland, Galway
- National University of Ireland
- National University Ireland, Galway
This publication has 75 references indexed in Scilit:
- Assessment of Material By-Product Fate from Bioresorbable Vascular ScaffoldsAnnals of Biomedical Engineering, 2011
- Modeling of Deformation-Accelerated Breakdown of Polylactic Acid Biodegradable StentsJournal of Medical Devices, 2010
- Deformation-induced hydrolysis of a degradable polymeric cylindrical annulusBiomechanics and Modeling in Mechanobiology, 2009
- Bioabsorbable Coronary StentsCirculation: Cardiovascular Interventions, 2009
- Constitutive Framework for Biodegradable Polymers with Applications to Biodegradable StentsASAIO Journal, 2008
- Effects of rapid crystallization on hydrolytic degradation and mechanical properties of poly(l-lactide-co-ε-caprolactone)Reactive and Functional Polymers, 2006
- Cardiovascular stent design and vessel stresses: a finite element analysisJournal of Biomechanics, 2005
- In vitro degradation of poly(L‐ lactic acid) fibers in phosphate buffered salineJournal of Applied Polymer Science, 2002
- In vitro study of poly(lactic acid) pin degradationPolymer, 1999
- Pathobiologic Responses to Stenting 11Supported in part by grants from the National Institutes of Health (GM/HL49039 and HL03104), the Burroughs Wellcome Fund for Experimental Therapeutics, Durham, North Carolina, and the Whitaker Foundation, Rosslyn, Virginia.The American Journal of Cardiology, 1998