Analytical, Stochastic and Experimental Solution of the Osteosynthesis of the Fifth Metatarsal by Headless Screw
Authors:
- Kateřina VlčkováKVKateřina Vlčková
- Karel FrydrýšekKarel Frydrýšek
- Vojtěch BajtekVBVojtěch Bajtek
- Jiří DemelJDJiří Demel
- Leopold PlevaLPLeopold Pleva
- Miroslav HavlíčekMHMiroslav Havlíček
- Jana PometlováJPJana Pometlová
- Roman MadejaRMRoman Madeja
- Jiří KratochvílJKJiří Kratochvíl
- Pavel KrpecPKPavel Krpec
- Paweł OsemlakPOPaweł Osemlak
- Kristina ČabanováKČKristina Čabanová
Open Access
- 25 September 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 9615
Abstract
This paper evaluates the various approaches to strength and stiffness analysis of fracture osteosynthesis using a headless Herbert screw. The problem has been extensively addressed using several scientific approaches, namely the analytical approach, stochastic approach, experimental approach, and (marginally) using the finite elements method. The problem is illustrated on the use of a prototype headless screw Ti: 4.0/1.4 × 30/7 (manufacturer: Medin, Czech Republic) and the surgical treatment of the fifth metatarsal fracture. Mathematical equations for the analytical calculation of the maximum stresses in the screw were established for tensile/compression loading. This problem is also interesting because of its static indetermination in tension and compression; for this reason, it was necessary to use the deformation condition, i.e., the relationship between screw extension and bone contraction. The stochastic (probabilistic) approach, i.e., application of the Monte Carlo method, takes advantage of the mathematical equations derived during the analytical solution by respecting of the natural variabilities and uncertainties. The analytical and stochastic approaches were validated by measurements on porcine bones and by the finite element method. The data measured experimentally were also processed and used for deriving an equation, appropriately approximating the data. The main part of the measurement was to determine the axial force generated during osteosynthesis with a headless screw. The obtained compressional force was used to determine the maximal stress in the screw and bone. Finally, the methods were compared. In this paper, comprehensive and original approaches based on the authors’ experience with multiple methods are presented. Obtained results are necessary for headless screw designers during optimalization of the implants and are also useful for surgeons developing new surgical techniques. This biomechanical problem was solved in cooperation with the engineering industry and physicians to improve the quality of care for patients with trauma in orthopedics and surgery.Keywords
Funding Information
- European Union (SP2022/26, CZ.02.1.01/0.0/17_049/0008407, CZ.02.1.01/0.0/0.0/17_049/0008441)
This publication has 16 references indexed in Scilit:
- STOCHASTIC STRENGTH ANALYSIS OF COMPRESSION HEADLESS SCREWMM Science Journal, 2020
- OSTEOSYNTHESIS OF THE FRACTURED FIFTH METATARSUS WITH HEADLESS SCREW2019
- Strength Analyses of Screws for Femoral Neck FracturesJournal of Medical and Biological Engineering, 2018
- Using of mobile flood protection on the territory of the Moldova as possible protection of the communityIOP Conference Series: Earth and Environmental Science, 2017
- Analysis of Locking Self-Taping Bone Screws for Angularly Stable PlatesJournal of Medical and Biological Engineering, 2017
- Inflammation, fracture and bone repairBone, 2016
- Stochastic Computer Approach Applied in the Reliability Assessment of Engineering Structures2016
- Distinguishing Jones and Proximal Diaphyseal Fractures of the Fifth MetatarsalClinical Orthopaedics and Related Research, 2008
- Correlation of cancellous bone microarchitectural parameters from microCT to CT number and bone mechanical propertiesMaterials Science and Engineering: C, 2007
- Differentiating Human Bone from Animal Bone: A Review of Histological MethodsJournal of Forensic Sciences, 2007