Leopold Pleva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leopold Pleva has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Karel Frydrýšek
Department of Applied Mechanics, Faculty of Mechanical Engineering , VSB – Technical University of Ostrava , 17. listopadu 2172/15 , Ostrava – Poruba , Czech Republic
7 shared publications - Roman Madeja
Department of Trauma Surgery, University Hospital Ostrava, Ostrava, Czech Republic
7 shared publications - Pavel Krpec
V-NASS, A.S., Halasova 2938/1a, 703 00 Ostrava, Czech Republic
5 shared publications - Daniel Čepica
Department of Applied Mechanics, Faculty of Mechanical Engineering , VSB – Technical University of Ostrava , 17. listopadu 2172/15 , Ostrava – Poruba , Czech Republic
4 shared publications - Jana Pometlová
Department of Trauma Surgery, University Hospital Ostrava, Ostrava, Czech Republic
4 shared publications - Tomáš Halo
Faculty of Mechanical Engineering, VSB—Technical University of Ostrava, 17. listopadu 15/2172, 70800 Ostrava-Poruba, Czech Republic
4 shared publications
Latest Publications
- Open Access
- 25 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 9615
Analytical, Stochastic and Experimental Solution of the Osteosynthesis of the Fifth Metatarsal by Headless Screw
This paper evaluates the various approaches to strength and stiffness analysis of fracture osteosynthesis using a headless Herbert screw. The problem has been extensively addressed using several scientific approaches, namely the analytical approach, stochastic approach, experimental approach, and (marginally) using the finite elements method. The problem is illustrated on the use of a prototype headless screw Ti: 4.0/1.4 × 30/7 (manufacturer: Medin, Czech Republic) and the surgical treatment of the fifth metatarsal fracture. Mathematical equations for the analytical calculation of the maximum stresses in the screw were established for tensile/compression loading. This problem is also interesting because of its static indetermination in tension and compression; for this reason, it was necessary to use the deformation condition, i.e., the relationship between screw extension and bone contraction. The stochastic (probabilistic) approach, i.e., application of the Monte Carlo method, takes advantage of the mathematical equations derived during the analytical solution by respecting of the natural variabilities and uncertainties. The analytical and stochastic approaches were validated by measurements on porcine bones and by the finite element method. The data measured experimentally were also processed and used for deriving an equation, appropriately approximating the data. The main part of the measurement was to determine the axial force generated during osteosynthesis with a headless screw. The obtained compressional force was used to determine the maximal stress in the screw and bone. Finally, the methods were compared. In this paper, comprehensive and original approaches based on the authors’ experience with multiple methods are presented. Obtained results are necessary for headless screw designers during optimalization of the implants and are also useful for surgeons developing new surgical techniques. This biomechanical problem was solved in cooperation with the engineering industry and physicians to improve the quality of care for patients with trauma in orthopedics and surgery.
- 25 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (19) , 9615
Open AccessAnalytical, Stochastic and Experimental Solution of the Osteosynthesis of the Fifth Metatarsal by Headless Screw
This paper evaluates the various approaches to strength and stiffness analysis of fracture osteosynthesis using a headless Herbert screw. The problem has been extensively addressed using several scientific approaches, namely the analytical approach, stochastic approach, experimental approach, and (marginally) using the finite elements method. The problem is illustrated on the use of a prototype headless screw Ti: 4.0/1.4 × 30/7 (manufacturer: Medin, Czech Republic) and the surgical treatment of the fifth metatarsal fracture. Mathematical equations for the analytical calculation of the maximum stresses in the screw were established for tensile/compression loading. This problem is also interesting because of its static indetermination in tension and compression; for this reason, it was necessary to use the deformation condition, i.e., the relationship between screw extension and bone contraction. The stochastic (probabilistic) approach, i.e., application of the Monte Carlo method, takes advantage of the mathematical equations derived during the analytical solution by respecting of the natural variabilities and uncertainties. The analytical and stochastic approaches were validated by measurements on porcine bones and by the finite element method. The data measured experimentally were also processed and used for deriving an equation, appropriately approximating the data. The main part of the measurement was to determine the axial force generated during osteosynthesis with a headless screw. The obtained compressional force was used to determine the maximal stress in the screw and bone. Finally, the methods were compared. In this paper, comprehensive and original approaches based on the authors’ experience with multiple methods are presented. Obtained results are necessary for headless screw designers during optimalization of the implants and are also useful for surgeons developing new surgical techniques. This biomechanical problem was solved in cooperation with the engineering industry and physicians to improve the quality of care for patients with trauma in orthopedics and surgery.
- Open Access
- 25 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7470
Biomechanical Assessment of Cannulated Nails for the Treatment of Proximal Femur Fractures
This article focuses on a type of surgical implant used in orthopaedics and traumatology—cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.
- 25 July 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (15) , 7470
Open AccessBiomechanical Assessment of Cannulated Nails for the Treatment of Proximal Femur Fractures
This article focuses on a type of surgical implant used in orthopaedics and traumatology—cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.
- Open Access
- 23 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 5265
Numerical Analysis of the Calcaneal Nail C-NAIL
The presented article investigates the biomechanics of the calcaneal nail C-NAILTM by numerical calculations and, partially, experimentally. This nail is widely used in trauma and orthopaedics. A numerical model of implants directly interacting with the bone tissue model obtained from CT scans was calculated. The material properties of the bone tissue can be described by several models; in this work, a non-homogeneous material model with isotropic elements and prescribed elastic modulus was used to provide a more accurate model of the applied force distribution on the individual parts of the implants. The critical areas of the nail and its fixtures were investigated using finite element strength calculations to verify their strength and reliability, contributing to the safety and faster and easier treatment of patients. These analyses suggest that the strength of the calcaneal nail C-NAIL, as well as the stabilization of bone fragments resulting from its use, are sufficient for clinical practice.
- 23 May 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (10) , 5265
Open AccessNumerical Analysis of the Calcaneal Nail C-NAIL
The presented article investigates the biomechanics of the calcaneal nail C-NAILTM by numerical calculations and, partially, experimentally. This nail is widely used in trauma and orthopaedics. A numerical model of implants directly interacting with the bone tissue model obtained from CT scans was calculated. The material properties of the bone tissue can be described by several models; in this work, a non-homogeneous material model with isotropic elements and prescribed elastic modulus was used to provide a more accurate model of the applied force distribution on the individual parts of the implants. The critical areas of the nail and its fixtures were investigated using finite element strength calculations to verify their strength and reliability, contributing to the safety and faster and easier treatment of patients. These analyses suggest that the strength of the calcaneal nail C-NAIL, as well as the stabilization of bone fragments resulting from its use, are sufficient for clinical practice.
- Open Access
- 19 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1015
Stochastic Strength Analyses of Screws for Femoral Neck Fractures
This paper represents a multidisciplinary approach to biomechanics (medicine engineering and mathematics) in the field of collum femoris fractures, i.e., of osteosyntheses with femoral/cancellous screws with full or cannulated cross-sections. It presents our new numerical model of femoral screws together with their stochastic (probabilistic, statistical) assessment. In the first part of this article, the new simple numerical model is presented. The model, based on the theory of planar (2D) beams on an elastic foundation and on 2nd-order theory, is characterized by rapid solution. Bending and compression loadings were used for derivation of a set of three 4th-order differential equations. Two examples (i.e., a stainless-steel cannulated femoral screw and full cross-section made of Ti6Al4V material) are presented, explained, and evaluated. In the screws, the internal shearing forces, internal normal forces, internal bending moments, displacement (deflections), slopes, and mechanical stresses are calculated using deterministic and stochastic approaches. For the stochastic approach and a “fully” probabilistic reliability assessment (which is a current trend in science), the simulation-based reliability assessment method, namely, the application of the direct Monte Carlo Method, using Anthill software, is applied. The probabilities of plastic deformations in femoral screws are calculated. Future developments, which could be associated with different configurations of cancellous screws, nonlinearities, experiments, and applications, are also proposed.
- 19 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1015
Open AccessStochastic Strength Analyses of Screws for Femoral Neck Fractures
This paper represents a multidisciplinary approach to biomechanics (medicine engineering and mathematics) in the field of collum femoris fractures, i.e., of osteosyntheses with femoral/cancellous screws with full or cannulated cross-sections. It presents our new numerical model of femoral screws together with their stochastic (probabilistic, statistical) assessment. In the first part of this article, the new simple numerical model is presented. The model, based on the theory of planar (2D) beams on an elastic foundation and on 2nd-order theory, is characterized by rapid solution. Bending and compression loadings were used for derivation of a set of three 4th-order differential equations. Two examples (i.e., a stainless-steel cannulated femoral screw and full cross-section made of Ti6Al4V material) are presented, explained, and evaluated. In the screws, the internal shearing forces, internal normal forces, internal bending moments, displacement (deflections), slopes, and mechanical stresses are calculated using deterministic and stochastic approaches. For the stochastic approach and a “fully” probabilistic reliability assessment (which is a current trend in science), the simulation-based reliability assessment method, namely, the application of the direct Monte Carlo Method, using Anthill software, is applied. The probabilities of plastic deformations in femoral screws are calculated. Future developments, which could be associated with different configurations of cancellous screws, nonlinearities, experiments, and applications, are also proposed.
- Open Access
- 12 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (2) , 362
Outcomes of Mini-Invasive Arthroscopic Arthrolysis Combined with Locking Screw and/or Intramedullary Nail Extraction after Osteosynthesis of the Proximal Humerus Fracture
Data on the effectiveness of arthroscopic arthrolysis and extraction of osteosynthetic material after osteosynthesis of the proximal humerus in patients with persisting problems are rare and insufficient. In this study, we performed arthroscopic arthrolysis and extraction of fixation screws, and, where protruding, extraction of the nail in 34 patients with problems persisting 12 months after osteosynthesis of the proximal humerus using an intramedullary nail. The effectiveness of the treatment was assessed using the Constant–Murley shoulder score and forward flexion difference between the treated arm and the contralateral one. A median increase of 16 points in CMS score and 30 degrees reduction in the arm forward flexion difference was recorded 12 months after the arthroscopy. The improvement was significantly higher in the patient group with intramedullary nail extraction (however, this group had worse pre-operative values and the screw was only extracted where likely to cause problems). The median time to heal was 11 weeks; no serious peri- or post-procedural complications occurred. Mini-invasive arthroscopic arthrolysis combined with extraction of osteosynthetic material proved to be a safe and effective method for treatment of patients after osteosynthesis of the proximal humerus using an intramedullary nail with persisting pain and/or mobility limitation.
- 12 January 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (2) , 362
Open AccessOutcomes of Mini-Invasive Arthroscopic Arthrolysis Combined with Locking Screw and/or Intramedullary Nail Extraction after Osteosynthesis of the Proximal Humerus Fracture
Data on the effectiveness of arthroscopic arthrolysis and extraction of osteosynthetic material after osteosynthesis of the proximal humerus in patients with persisting problems are rare and insufficient. In this study, we performed arthroscopic arthrolysis and extraction of fixation screws, and, where protruding, extraction of the nail in 34 patients with problems persisting 12 months after osteosynthesis of the proximal humerus using an intramedullary nail. The effectiveness of the treatment was assessed using the Constant–Murley shoulder score and forward flexion difference between the treated arm and the contralateral one. A median increase of 16 points in CMS score and 30 degrees reduction in the arm forward flexion difference was recorded 12 months after the arthroscopy. The improvement was significantly higher in the patient group with intramedullary nail extraction (however, this group had worse pre-operative values and the screw was only extracted where likely to cause problems). The median time to heal was 11 weeks; no serious peri- or post-procedural complications occurred. Mini-invasive arthroscopic arthrolysis combined with extraction of osteosynthetic material proved to be a safe and effective method for treatment of patients after osteosynthesis of the proximal humerus using an intramedullary nail with persisting pain and/or mobility limitation.
- Open Access
- 9 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (2) , 614
Biomechanical Analysis of Staples for Epiphysiodesis
Limb asymmetry can, and often does, cause various health problems. Blount bone staples (clips) are used to correct such uneven growth. This article analyzes the performance of a biomechanical staple during bone (tibia) growth arrest. The staples considered in this study were made of 1.4441 stainless steel, the model of tibia consisted of two materials representing corticalis and spongiosis. Hooke’s law was used for modeling materials’ behaviors for finite element analysis (FEA). The maxima of stress and total staple displacement were evaluated using the finite element method and verification of the results, along with the determination of the maximum loading (growing) force that the staples are capable of withstanding, was performed experimentally. The presented method can be used to determine the safety and usability of staples for bone growth arrest. According to our results, the design of Blount staples considered in this paper is safe and suitable for orthopedic treatment.
- 9 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (2) , 614
Open AccessBiomechanical Analysis of Staples for Epiphysiodesis
Limb asymmetry can, and often does, cause various health problems. Blount bone staples (clips) are used to correct such uneven growth. This article analyzes the performance of a biomechanical staple during bone (tibia) growth arrest. The staples considered in this study were made of 1.4441 stainless steel, the model of tibia consisted of two materials representing corticalis and spongiosis. Hooke’s law was used for modeling materials’ behaviors for finite element analysis (FEA). The maxima of stress and total staple displacement were evaluated using the finite element method and verification of the results, along with the determination of the maximum loading (growing) force that the staples are capable of withstanding, was performed experimentally. The presented method can be used to determine the safety and usability of staples for bone growth arrest. According to our results, the design of Blount staples considered in this paper is safe and suitable for orthopedic treatment.
- Open Access
Tension Hemothorax in Aortic Rupture: A Case Report
Background: The standard ATLS protocol calls for chest drain insertion in patients with hemothorax before performing further diagnostic steps. However, if trauma-induced thoracic aortic rupture is the underlying cause, such drainage can lead to massive bleeding and death of the patient. Case report: This report describes a case of a polytrauma patient (car accident), aged 21, with symmetrical chest and decreased breath sounds dorsally on the left. An urgent CT scan revealed subadventitial Grade III thoracic aortic transection with mediastinal hematoma, a massive left-sided hemothorax with mediastinal shift to the right, and other injuries. Stent-graft implantation with subsequent left hemithorax drainage was urgently performed, during which the patient became increasingly unstable from the circulatory point of view. This traumatic hemorrhagic shock was successfully managed at the ICU. Conclusion: Although hemothorax is a serious condition requiring rapid treatment, the knowledge of its origin is of utmost importance; performing chest drainage without bleeding control can lead to circulatory instability and death of the patient. Hence, where aortic injury can be suspected based on the mechanism of the injury, it is beneficial to perform spiral CT angiography for accurate diagnosis first and, in cases of aortic injury, to control the bleeding prior to drainage.
Open AccessTension Hemothorax in Aortic Rupture: A Case Report
Background: The standard ATLS protocol calls for chest drain insertion in patients with hemothorax before performing further diagnostic steps. However, if trauma-induced thoracic aortic rupture is the underlying cause, such drainage can lead to massive bleeding and death of the patient. Case report: This report describes a case of a polytrauma patient (car accident), aged 21, with symmetrical chest and decreased breath sounds dorsally on the left. An urgent CT scan revealed subadventitial Grade III thoracic aortic transection with mediastinal hematoma, a massive left-sided hemothorax with mediastinal shift to the right, and other injuries. Stent-graft implantation with subsequent left hemithorax drainage was urgently performed, during which the patient became increasingly unstable from the circulatory point of view. This traumatic hemorrhagic shock was successfully managed at the ICU. Conclusion: Although hemothorax is a serious condition requiring rapid treatment, the knowledge of its origin is of utmost importance; performing chest drainage without bleeding control can lead to circulatory instability and death of the patient. Hence, where aortic injury can be suspected based on the mechanism of the injury, it is beneficial to perform spiral CT angiography for accurate diagnosis first and, in cases of aortic injury, to control the bleeding prior to drainage.
- Open Access
- 17 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5616
Mechanics of Screw Joints Solved as Beams Placed in a Tangential Elastic Foundation
This article deals with a new original analytical solution of deformation, force and stress states in wood screw joints up to the limit values of pulling out/breaking the screw. The screws are under tension. The wood-to-screw interaction is effectively simplified by introducing several physical model variants using a tangential elastic non-linear foundation. The experimental verification of the proposed models using pull-out tests (i.e., pulling out screws from dry spruce wood in laboratory conditions) confirms the correctness of the proposed models of the elastic linear/non-linear foundation. The validity of the model is also analytically and experimentally verified in the biomechanical model of pulling out screws from the femur of a bovine/human cadaver, which confirms and expands the validity of newly designed screw joint models outside the timber structure area.
- 17 June 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (12) , 5616
Open AccessMechanics of Screw Joints Solved as Beams Placed in a Tangential Elastic Foundation
This article deals with a new original analytical solution of deformation, force and stress states in wood screw joints up to the limit values of pulling out/breaking the screw. The screws are under tension. The wood-to-screw interaction is effectively simplified by introducing several physical model variants using a tangential elastic non-linear foundation. The experimental verification of the proposed models using pull-out tests (i.e., pulling out screws from dry spruce wood in laboratory conditions) confirms the correctness of the proposed models of the elastic linear/non-linear foundation. The validity of the model is also analytically and experimentally verified in the biomechanical model of pulling out screws from the femur of a bovine/human cadaver, which confirms and expands the validity of newly designed screw joint models outside the timber structure area.
- Open Access
- 1 November 2019
- Published by Walter de Gruyter GmbH in Strojnícky časopis - Journal of Mechanical Engineering
- Vol. 69 (3) , 51-60
Biomechanics – Experimental Determination of Critical Force Needed for Cannula to be Torn out
The aim of this paper is to determinate critical (tearing) force. This force is needed to be caused, for cannula and its securing fixation (in this case by tapes), to be torn out from patient’s body, (i.e. applications in medico-chirurgical branches). To determine this quantity, experimental approach was used, in which for more realistic approach real human cutis (skin) was used. Data acquired from this experiment may be later used in designing of a device for automatic winding of infusion tubes etc. Measurements were performed on porcine and human skin.
- 1 November 2019
- Published by Walter de Gruyter GmbH in Strojnícky časopis - Journal of Mechanical Engineering
- Vol. 69 (3) , 51-60
Open AccessBiomechanics – Experimental Determination of Critical Force Needed for Cannula to be Torn out
The aim of this paper is to determinate critical (tearing) force. This force is needed to be caused, for cannula and its securing fixation (in this case by tapes), to be torn out from patient’s body, (i.e. applications in medico-chirurgical branches). To determine this quantity, experimental approach was used, in which for more realistic approach real human cutis (skin) was used. Data acquired from this experiment may be later used in designing of a device for automatic winding of infusion tubes etc. Measurements were performed on porcine and human skin.
- Open Access
- 15 December 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 118
Tissue ischemia microdialysis assessments following severe traumatic haemorrhagic shock: lactate/pyruvate ratio as a new resuscitation end point?
Intensive care of severe trauma patients focuses on the treatment of haemorrhagic shock. Tissues should be perfused sufficiently with blood and with sufficient oxygen content to ensure adequate tissue oxygen delivery. Tissue metabolism can be monitored by microdialysis, and the lactate/pyruvate ratio (LPR) may be used as a tissue ischemia marker. The aim of this study was to determine the adequate cardiac output and haemoglobin levels that avoid tissue ischemia. Adult patients with serious traumatic haemorrhagic shock were enrolled in this prospective observational study. The primary observed parameters included haemoglobin, cardiac output, central venous saturation, arterial lactate and the tissue lactate/pyruvate ratio. Forty-eight patients were analysed. The average age of the patients was 39.8 ± 16.7, and the average ISS was 43.4 ± 12.2. Hb < 70 g/l was associated with pathologic arterial lactate, ScvO2 and LPR. Tissue ischemia (i.e., LPR over 25) developed when CI ≤ 3.2 l/min/m2 and Hb between 70 and 90 g/l were observed. Severe tissue ischemia events were recorded when the Hb dropped below 70 g/l and CI was 3.2-4.8 l/min/m2. CI ≥ 4.8 l/min/m2 was not found to be connected with tissue ischemia, even when Hb ≤ 70 g/l. LPR could be a useful marker to manage traumatic haemorrhagic shock therapies. In initial traumatic haemorrhagic shock treatments, it may be better to maintain CI ≥ 3.2 l/min/m2 and Hb ≥ 70 g/l to avoid tissue ischemia. LPR could also be a useful transfusion trigger when it may demonstrate ischemia onset due to low local DO2 and early reveal low/no tissue perfusion.
- 15 December 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 118
Open AccessTissue ischemia microdialysis assessments following severe traumatic haemorrhagic shock: lactate/pyruvate ratio as a new resuscitation end point?
Intensive care of severe trauma patients focuses on the treatment of haemorrhagic shock. Tissues should be perfused sufficiently with blood and with sufficient oxygen content to ensure adequate tissue oxygen delivery. Tissue metabolism can be monitored by microdialysis, and the lactate/pyruvate ratio (LPR) may be used as a tissue ischemia marker. The aim of this study was to determine the adequate cardiac output and haemoglobin levels that avoid tissue ischemia. Adult patients with serious traumatic haemorrhagic shock were enrolled in this prospective observational study. The primary observed parameters included haemoglobin, cardiac output, central venous saturation, arterial lactate and the tissue lactate/pyruvate ratio. Forty-eight patients were analysed. The average age of the patients was 39.8 ± 16.7, and the average ISS was 43.4 ± 12.2. Hb < 70 g/l was associated with pathologic arterial lactate, ScvO2 and LPR. Tissue ischemia (i.e., LPR over 25) developed when CI ≤ 3.2 l/min/m2 and Hb between 70 and 90 g/l were observed. Severe tissue ischemia events were recorded when the Hb dropped below 70 g/l and CI was 3.2-4.8 l/min/m2. CI ≥ 4.8 l/min/m2 was not found to be connected with tissue ischemia, even when Hb ≤ 70 g/l. LPR could be a useful marker to manage traumatic haemorrhagic shock therapies. In initial traumatic haemorrhagic shock treatments, it may be better to maintain CI ≥ 3.2 l/min/m2 and Hb ≥ 70 g/l to avoid tissue ischemia. LPR could also be a useful transfusion trigger when it may demonstrate ischemia onset due to low local DO2 and early reveal low/no tissue perfusion.