Trifecta St. Jude medical® aortic valve in pulmonary position
Open Access
- 1 January 2017
- journal article
- research article
- Published by Taylor & Francis in Nano Reviews & Experiments
- Vol. 8 (1) , 1299900
Abstract
Introduction: To evaluate an aortic pericardial valve for pulmonary valve (PV) regurgitation after repair of congenital heart defects. Methods: From July 2012 to June 2016 71 patients, mean age 24 ± 13 years (four to years) underwent PV implantation of aortic pericardial valve, mean interval after previous repair = 21 ± 10 years (two to 47 years). Previous surgery at mean age 3.2 ± 7.2 years (one day to 49 years): tetralogy of Fallot repair in 83% (59/71), pulmonary valvotomy in 11% (8/71), relief of right ventricular outflow tract (RVOT) obstruction in 6% (4/71). Pre-operative echocardiography and MRI showed severe PV regurgitation in 97% (69/71), moderate in 3% (2/71) with associated RVOT obstruction. MRI and knowledge-based reconstruction 3D volumetry (KBR-3D-volumetry) showed mean PV regurgitation = 42 ± 9% (20–58%), mean indexed RV end-diastolic volume = 169 ± 33 (130–265) ml m–2 BSA and mean ejection fraction (EF) = 46 ± 8% (33–61%). Cardio-pulmonary exercise showed mean peak O2/uptake = 24 ± 8 ml kg–1 min–1 (14–45 ml kg–1 min–1), predicted max O2/uptake 66 ± 17% (26–97%). Pre-operative NYHA class was I in 17% (12/71) patients, II in 70% (50/71) and III in 13% (9/71). Results: Mean cardio-pulmonary bypass duration was 95 ± 30ʹ (38–190ʹ), mean aortic cross-clamp in 23% (16/71) 46 ± 31ʹ (8–95ʹ), with 77% (55/71) implantations without aortic cross-clamp. Size of implanted PV: 21 mm in seven patients, 23 mm in 33, 25 mm in 23, and 27 mm in eight. The z-score of the implanted PV was −0.16 ± 0.80 (−1.6 to 2.5), effective orifice area indexed (for BSA) of native PV was 1.5 ± 0.2 (1.2 to –2.1) vs. implanted PV 1.2 ± 0.3 (0.76 to –2.5) (p = ns). In 76% (54/71) patients surgical RV modelling was associated. Mean duration of mechanical ventilation was 6 ± 5 h (0–26 h), mean ICU stay 21 ± 11 h (12–64 h), mean hospital stay 6 ± 3 days (three to 19 days). In mean follow-up = 25 ± 14 months (six to 53 months) there were no early/late deaths, no need for cardiac intervention/re-operation, no valve-related complications, thrombosis or endocarditis. Last echocardiography showed absent PV regurgitation in 87.3% (62/71) patients, trivial/mild degree in 11.3% (8/71), moderate degree in 1.45% (1/71), mean max peak velocity through RVOT 1.6 ± 0.4 (1.0–2.4) m s–1. Mean indexed RV end-diastolic volume at MRI/KBR-3D-volumetry was 96 ± 20 (63–151) ml m–2 BSA, lower than pre-operatively (p < 0.001), and mean EF = 55 ± 4% (49–61%), higher than pre-operatively (p < 0.05). Almost all patients (99% = 70/71) remain in NYHA class I, 1.45% = 1/71 in class II. Conclusion: (a) Aortic pericardial valve is implantable in PV position with an easy and reproducible surgical technique; (b) valve size adequate for patient BSA can be implanted with simultaneous RV remodelling; (c) medium-term outcomes are good with maintained PV function, RV dimensions significantly reduced and EF significantly improved; (d) adequate valve size will allow later percutaneous valve-in-valve implantation.Keywords
This publication has 53 references indexed in Scilit:
- Pulmonary valve replacement for congenital heart disease: What valve substitute should we be using?The Journal of Thoracic and Cardiovascular Surgery, 2016
- Early European experience with the Venus P-valve®: filling the gap in percutaneous pulmonary valve implantationEuroIntervention, 2016
- Pulmonary valve replacement in older children and adults using stented bioprosthesesMultimedia Manual of Cardio-Thoracic Surgery, 2016
- Differential Impact of Pulmonary Regurgitation on Patients With Surgically Repaired Pulmonary Stenosis Versus Tetralogy of FallotThe American Journal of Cardiology, 2016
- Hemodynamic performance of Trifecta: Single-center experience of 400 patientsAsian Cardiovascular and Thoracic Annals, 2014
- Which is the best tissue valve used in the pulmonary position, late after previous repair of tetralogy of Fallot?: Table 1:Interactive CardioVascular and Thoracic Surgery, 2013
- Younger age and valve oversizing are predictors of structural valve deterioration after pulmonary valve replacement in patients with tetralogy of FallotThe Journal of Thoracic and Cardiovascular Surgery, 2012
- Homograft survival after tetralogy of Fallot repair: determinants of accelerated homograft degenerationEuropean Heart Journal, 2007
- Surgical Management of Right Ventricular Dysfunction Late After Repair of Tetralogy of Fallot: Right Ventricular Remodeling SurgerySeminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual, 2006
- Factors associated with impaired clinical status in long-term survivors of tetralogy of Fallot repair evaluated by magnetic resonance imagingJACC, 2004