GSGregory James Skinner

Gregory James Skinner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gregory James Skinner has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Novel loss of function mutation in NOTCH1 in a family with bicuspid aortic valve, ventricular septal defect, thoracic aortic aneurysm, and aortic valve stenosis

    by Radoslaw Debiec, Stephen E. Hamby, Peter D. Jones, Sue Coolman, Manish Asiani, Shireen Kharodia, Gregory J. Skinner, Nilesh J. Samani, Tom R. Webb, Aidan Bolger

    Background: Bicuspid aortic valve is the most common congenital valvular heart defect in the general population. BAV is associated with significant morbidity due to valve failure, formation of thoracic aortic aneurysm, and increased risk of infective endocarditis and aortic dissection. Loss of function mutations in NOTCH1 (OMIM 190198) has previously been associated with congenital heart disease involving the aortic valve, left ventricle outflow tract, and mitral valve that segregates in affected pedigrees as an autosomal dominant trait with variable expressivity.Methods: We performed whole‐exome sequencing in four members of a three‐generational family (three affected and one unaffected subject) with clinical phenotypes including aortic valve stenosis, thoracic aortic aneurysm, and ventricular septal defect.Results: We identified 16 potentially damaging genetic variants (one stop variant, one splice variant, and 14 missense variants) cosegregating with the phenotype. Of these variants, the nonsense mutation (p.Tyr291*) in NOTCH1 was the most deleterious variant identified and the most likely variant causing the disease.Conclusion: Inactivating NOTCH1 mutations are a rare cause of familial heart disease involving predominantly left ventricular outflow tract lesions and characterized by the heterogeneity of clinical phenotype.


  • Open Access

    Echocardiographic Assessment of Pulmonary Arterial Hypertension for Pediatricians and Neonatologists

    by Gregory James Skinner

    There is a growing awareness of the role that increased pulmonary vascular resistance (PVR) plays in many pathologies, therefore assessment of pulmonary artery pressure is an increasingly requested investigation in the critical care environment. This article will go through the basic concepts regarding pulmonary artery pressure (PAP) and PVR, then will go on to outline the various echocardiographic parameters which are used to assess them. Finally, an outline of how to undertake this assessment will be presented.


  • Open Access

    Trifecta St. Jude medical® aortic valve in pulmonary position

    by Antonio F. Corno, Alan G. Dawson, Aidan P. Bolger, Branco Mimic, Suhair O. Shebani, Gregory J. Skinner, Simone Speggiorin

    Introduction: To evaluate an aortic pericardial valve for pulmonary valve (PV) regurgitation after repair of congenital heart defects. Methods: From July 2012 to June 2016 71 patients, mean age 24 ± 13 years (four to years) underwent PV implantation of aortic pericardial valve, mean interval after previous repair = 21 ± 10 years (two to 47 years). Previous surgery at mean age 3.2 ± 7.2 years (one day to 49 years): tetralogy of Fallot repair in 83% (59/71), pulmonary valvotomy in 11% (8/71), relief of right ventricular outflow tract (RVOT) obstruction in 6% (4/71). Pre-operative echocardiography and MRI showed severe PV regurgitation in 97% (69/71), moderate in 3% (2/71) with associated RVOT obstruction. MRI and knowledge-based reconstruction 3D volumetry (KBR-3D-volumetry) showed mean PV regurgitation = 42 ± 9% (20–58%), mean indexed RV end-diastolic volume = 169 ± 33 (130–265) ml m–2 BSA and mean ejection fraction (EF) = 46 ± 8% (33–61%). Cardio-pulmonary exercise showed mean peak O2/uptake = 24 ± 8 ml kg–1 min–1 (14–45 ml kg–1 min–1), predicted max O2/uptake 66 ± 17% (26–97%). Pre-operative NYHA class was I in 17% (12/71) patients, II in 70% (50/71) and III in 13% (9/71). Results: Mean cardio-pulmonary bypass duration was 95 ± 30ʹ (38–190ʹ), mean aortic cross-clamp in 23% (16/71) 46 ± 31ʹ (8–95ʹ), with 77% (55/71) implantations without aortic cross-clamp. Size of implanted PV: 21 mm in seven patients, 23 mm in 33, 25 mm in 23, and 27 mm in eight. The z-score of the implanted PV was −0.16 ± 0.80 (−1.6 to 2.5), effective orifice area indexed (for BSA) of native PV was 1.5 ± 0.2 (1.2 to –2.1) vs. implanted PV 1.2 ± 0.3 (0.76 to –2.5) (p = ns). In 76% (54/71) patients surgical RV modelling was associated. Mean duration of mechanical ventilation was 6 ± 5 h (0–26 h), mean ICU stay 21 ± 11 h (12–64 h), mean hospital stay 6 ± 3 days (three to 19 days). In mean follow-up = 25 ± 14 months (six to 53 months) there were no early/late deaths, no need for cardiac intervention/re-operation, no valve-related complications, thrombosis or endocarditis. Last echocardiography showed absent PV regurgitation in 87.3% (62/71) patients, trivial/mild degree in 11.3% (8/71), moderate degree in 1.45% (1/71), mean max peak velocity through RVOT 1.6 ± 0.4 (1.0–2.4) m s–1. Mean indexed RV end-diastolic volume at MRI/KBR-3D-volumetry was 96 ± 20 (63–151) ml m–2 BSA, lower than pre-operatively (p < 0.001), and mean EF = 55 ± 4% (49–61%), higher than pre-operatively (p < 0.05). Almost all patients (99% = 70/71) remain in NYHA class I, 1.45% = 1/71 in class II. Conclusion: (a) Aortic pericardial valve is implantable in PV position with an easy and reproducible surgical technique; (b) valve size adequate for patient BSA can be implanted with simultaneous RV remodelling; (c) medium-term outcomes are good with maintained PV function, RV dimensions significantly reduced and EF significantly improved; (d) adequate valve size will allow later percutaneous valve-in-valve implantation.


  • Open Access

    Usefulness of Four-Dimensional Trans-Oesophageal Echocardiography in Device Closure of An Unusual Post Myocardial Infarction Ventricular Septal Defect

    by Gregory James Skinner, Christopher Duke, Suhair Omar Shebani

    Presentation of the transoesophageal echocardiogram for a patient undergoing transcatheter closure of a post infarction ventricular septal defect through a pseudoaneurysm at the basal rather than the apical part of the septum, posing a diagnostic and interventional planning challenge. Four dimensional imaging clarified the complex anatomy of the pseudoaneurysm, aiding device closure.

  • Reversible Regional Myocardial Ischemia in a Six‐Month‐Old Infant Post Arterial Switch Operation Demonstrated by Speckle Tracking Echocardiography

    by Gregory J. Skinner, Suhair O. Shebani

    Mini‐ We present the case of an infant with coronary artery stenosis following an arterial switch operation for transposition of the great arteries. He was demonstrated to have reversible regional myocardial ischemia using speckle tracking echocardiography (STE), which corresponded to the affected territory seen when he underwent cardiac catheterization with revascularization. This demonstrates the utility of STE in infants with regional myocardial dysfunction.

  • Open Access

    Tricuspid valve tissue in the left ventricular outflow tract following ventricular septal defect repair

    by Gregory James Skinner, Suhair Omar Shebani

    The operation note documents: “it was necessary to use quite a lot of the tricuspid leaflet to completely close the defect superiorly”. Owing to poor transthoracic windows, we arranged for the patient to undergo a three-dimensional transoesophageal echocardiogram to help to delineate the lesion.

  • ASD closure under pressure

    by Suhair Omar Shebani, Gregory James Skinner, Christopher Duke

    Transcatheter atrial septal defect device implantation in elderly patients may cause acute pulmonary oedema when impaired left ventricular diastolic function causes an abrupt increase in left atrial pressure. Though left atrial pressure is often monitored during test occlusion of a defect, it is not clear at what cut-off value device implantation is contraindicated. We report successful closure of an atrial septal defect in a 73-year-old patient, even though the mean left atrial pressure increased from 18 to 25 mm Hg with device implantation. Although a fenestrated device was used, this did not prevent the rise in left atrial pressure. The patient was supported with mechanical ventilation, milrinone and intravenous diuretics following the procedure and did not develop pulmonary oedema. Her dyspnoea improved and her functional status increased from New York Heart Association (NYHA) III to NYHA II. In conclusion, successful device closure can be accomplished even with high left atrial pressure.


  • How to write a Problem Solving in Clinical Practice paper

    by Gregory J Skinner

    An overview of the concept of problem solving in clinical practice, and how to go about writing an article to be submitted.


  • Atrial septal defect closure with an Amplatzer septal occluder fenestrated with a coronary stent in a child with pulmonary arterial hypertension

    by Gregory J. Skinner, Robert M. Tulloh, Andrew J. Tometzki, Ingram Schulze-Neick, Gareth J. Morgan

    The presence of an atrial septal defect in pulmonary hypertension has benefits and detractions. Even in idiopathic pulmonary arterial hypertension, a significant left-to-right shunt at atrial level may increase the pulmonary arterial pressure and exacerbate the disease. However, it is well recognised that the presence of an atrial communication may be protective in subgroups with severe disease, allowing maintenance of cardiac output during times of increased pulmonary resistance. In the present paper, we present the case of a young boy with significant idiopathic pulmonary arterial hypertension and an atrial septal defect. We report our technique of septal occlusion using a device to decrease left-to-right shunting with concomitant stent insertion in that device to maintain the potential for right-to-left shunting during times of high pulmonary arterial pressure.