Hemodynamic Results and Mid-term Follow-up of 850 19 to 23 mm Perimount Magna Ease Valves
- 1 August 2018
- journal article
- research article
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 67 (04) , 274-281
Abstract
Background Aortic valve replacement (AVR) in small aortic roots remains a surgical dilemma with a higher risk of patient-prosthesis mismatch (PPM). The Perimount Magna Ease aortic valve (PMEAV) represents an attractive device in such cases. We examined the early hemodynamic performance, the mid-term outcomes of the PMEAV, and the impact of PPM on outcome and functional class. Methods We performed a retrospective analysis of prospectively collected in-hospital data, and a prospective single-center follow-up of 849 patients who received a 19 to 23 mm PMEAV (2008–2014). Concomitant mitral or tricuspid replacement was the exclusion criterion. Early hemodynamic features were prospectively collected; mid-term follow-up was conducted according to current guidelines. Results Size of implanted prosthesis was 19 mm in 11.5% of patients, 21 mm in 36.9%, and 23 mm in 51.5%. Operative mortality was 4.5% (3.1% for isolated AVR). The rate of severe and moderate PPMs was significantly higher in the 19 mm group. Follow-up was 99.9% complete (3.7 ± 2 years). Actuarial freedom from structural valve deterioration (SVD) at 5 years was 99.1%. At stratified Kaplan–Meier's analysis, PPM and age <70 years were associated with SVD. PPM was not associated with worse functional status (New York Heart Association class) or mortality at follow-up. Conclusion This series shows satisfactory clinical outcomes of the PMEAV implanted in small aortic annuli at mid-term follow-up. Although PPM may occur in smaller sizes, it has limited clinical impact, and it is not associated with mid-term mortality or worse functional class. Few SVD events are evidenced; nonetheless, limited follow-up duration and its methodology need to be considered.Keywords
This publication has 20 references indexed in Scilit:
- Long-term results of the Medtronic Mosaic porcine bioprosthesis in the aortic positionThe Journal of Thoracic and Cardiovascular Surgery, 2014
- The impact of prosthesis–patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-yearsEuropean Heart Journal, 2012
- Absence of prosthesis–patient mismatch with the new generation of Edwards stented aortic bioprosthesis☆Interactive CardioVascular and Thoracic Surgery, 2010
- POINT: Prosthesis–patient mismatch does not affect survival for patients greater than 70 years of age undergoing bioprosthetic aortic valve replacementThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Guidelines for reporting mortality and morbidity after cardiac valve interventionsThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Enlargement of the Small Aortic Root During Aortic Valve Replacement: Is There a Benefit?The Annals of Thoracic Surgery, 2008
- Meta-Analysis of Valve Hemodynamics and Left Ventricular Mass Regression for Stentless Versus Stented Aortic ValvesThe Annals of Thoracic Surgery, 2007
- Carpentier-Edwards PERIMOUNT Magna bioprosthesis: A stented valve with stentless performance?The Journal of Thoracic and Cardiovascular Surgery, 2005
- Hemodynamic Comparison of Bioprostheses for Complete Supra-Annular Position in Patients With Small Aortic AnnulusJACC, 2005
- Impact of Valve Prosthesis-Patient Mismatch on Short-Term Mortality After Aortic Valve ReplacementCirculation, 2003