Phase transformation and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures
Authors:
Open Access
- 30 October 2023
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-10
Abstract
Background: The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of different heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures.Methods: Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05).Results: DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, VB, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05).Conclusions: Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, especially in the NCF values of instruments with a mixture of martensite/R-phase and austenite phases at the tested temperatures.Keywords
All Related Versions
Funding Information
- JST SPRING (JPMJSP2120)
- TMDU Research Fund (11BA)
This publication has 46 references indexed in Scilit:
- Nano‐indentation testing of new and fractured nickel‐titanium endodontic instrumentsInternational Endodontic Journal, 2011
- Phase transformation behaviour and bending property of twisted nickel-titanium endodontic instrumentsInternational Endodontic Journal, 2011
- Effect of heat treatment on transformation temperatures and bending properties of nickel–titanium endodontic instrumentsInternational Endodontic Journal, 2009
- Phase transformation behaviour and bending properties of hybrid nickel–titanium rotary endodontic instrumentsInternational Endodontic Journal, 2007
- Cyclic fatigue resistance and three‐dimensional analysis of instruments from two nickel–titanium rotary systemsInternational Endodontic Journal, 2006
- Influence of phase transformation on the torsional and bending properties of nickel–titanium rotary endodontic instrumentsInternational Endodontic Journal, 2006
- Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel‐titanium wires employed in the manufacture of rotary endodontic instrumentsInternational Endodontic Journal, 2005
- Physical metallurgy of Ti–Ni-based shape memory alloysProgress in Materials Science, 2005
- Questionnaire survey on the use of rotary nickel–titanium endodontic instruments by Australian dentistsInternational Endodontic Journal, 2004
- Bending properties and transformation temperatures of heat treated Ni‐Ti alloy wire for orthodontic appliancesJournal of Biomedical Materials Research, 1993