Shunsuke Kimura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shunsuke Kimura has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Arata Ebihara
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
10 shared publications - Keiichiro Maki
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
9 shared publications - Takashi Okiji
Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo 113-8549, Japan
9 shared publications - Satoshi Omori
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
8 shared publications - Hayate Unno
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
5 shared publications Keiichiro Maki
Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan
5 shared publications
Latest Publications
- Open Access
- 31 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 446
Effect of Different Downward Loads and Rotational Speeds on the Removal of Gutta-Percha and Root Canal Sealer Using a Nickel-Titanium Rotary Gutta-Percha Removal System: An Ex Vivo Study
Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aimed to examine how varying downward loads and rotational speeds affect the removal efficiency and torque/force generation of the HyFlex Remover. Sixty transparent straight resin canals filled with gutta-percha and AH Plus sealer were prepared using the HyFlex Remover at two rotational speeds (400 and 800 rpm) and three downward loads (2, 3, and 4 N; n = 10/group). The removal rate, calculated using micro-computed tomography, as well as removal time, maximum force, maximum torque, and cumulative torque were recorded and evaluated using two-way analysis of variance with Bonferroni correction (α = 0.05). The removal rate was consistently higher at 400 rpm than at 800 rpm (p < 0.001), while removal time and cumulative torque were greater at 400 rpm (p < 0.001). Maximum torque differed only between the 800-2 N and 800-4 N groups (p = 0.006). Maximum force increased with higher loads (p < 0.001), and at 3 N and 4 N, it was lower at 400 rpm than at 800 rpm (3 N: p = 0.039, 4 N: p < 0.001). Overall, lower downward loads reduced torque but prolonged working time, whereas higher rotational speeds shortened both working time and torque but decreased the removal rate.
- 31 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 446
Open AccessEffect of Different Downward Loads and Rotational Speeds on the Removal of Gutta-Percha and Root Canal Sealer Using a Nickel-Titanium Rotary Gutta-Percha Removal System: An Ex Vivo Study
Effective gutta-percha/sealer removal is essential for predictable nonsurgical endodontic retreatment, but the effects of key operational parameters on nickel–titanium rotary removal instruments remain insufficiently understood. This study aimed to examine how varying downward loads and rotational speeds affect the removal efficiency and torque/force generation of the HyFlex Remover. Sixty transparent straight resin canals filled with gutta-percha and AH Plus sealer were prepared using the HyFlex Remover at two rotational speeds (400 and 800 rpm) and three downward loads (2, 3, and 4 N; n = 10/group). The removal rate, calculated using micro-computed tomography, as well as removal time, maximum force, maximum torque, and cumulative torque were recorded and evaluated using two-way analysis of variance with Bonferroni correction (α = 0.05). The removal rate was consistently higher at 400 rpm than at 800 rpm (p < 0.001), while removal time and cumulative torque were greater at 400 rpm (p < 0.001). Maximum torque differed only between the 800-2 N and 800-4 N groups (p = 0.006). Maximum force increased with higher loads (p < 0.001), and at 3 N and 4 N, it was lower at 400 rpm than at 800 rpm (3 N: p = 0.039, 4 N: p < 0.001). Overall, lower downward loads reduced torque but prolonged working time, whereas higher rotational speeds shortened both working time and torque but decreased the removal rate.
- Open Access
Impact of Downward Load and Rotational Kinematics on Root Canal Instrumentation with a Heat-Treated Nickel–Titanium Rotary Instrument
This study analyzed how different downward loads and rotational kinematics influence NiTi rotary instrumentation outcomes. Heat-treated NiTi instruments were used to prepare extracted human single-rooted premolars with a moderate canal curvature. Instrumentation was performed using an automated endodontic instrumentation device with controlled downward loading and torque/force sensing, under different downward load settings (1, 2, and 3 N), employing either continuous rotation (CR) or optimum torque reverse (OTR) motion, which is a torque-sensitive reciprocation. Instrumentation was completed without instrument fracture or ledge formation in all six groups. OTR-3N specimens displayed a significantly lower upward force (i.e., screw-in force) than OTR-2N specimens (p < 0.05). OTR-1N specimens required a significantly longer instrumentation time than CR-1N specimens and the other OTR specimens (p < 0.05). At 1 mm from the apex, CR-2N specimens showed a significantly larger canal-centering ratio (i.e., larger deviation) than OTR-2N specimens (p < 0.05). Overall, applying a downward load of 2–3 N in OTR mode provided shaping efficiency similar to CR, but with a reduced screw-in force and enhanced canal-centering in the apical region, supporting the use of OTR as a promising alternative to CR for curved canal preparation using heat-treated NiTi instruments.
Open AccessImpact of Downward Load and Rotational Kinematics on Root Canal Instrumentation with a Heat-Treated Nickel–Titanium Rotary Instrument
This study analyzed how different downward loads and rotational kinematics influence NiTi rotary instrumentation outcomes. Heat-treated NiTi instruments were used to prepare extracted human single-rooted premolars with a moderate canal curvature. Instrumentation was performed using an automated endodontic instrumentation device with controlled downward loading and torque/force sensing, under different downward load settings (1, 2, and 3 N), employing either continuous rotation (CR) or optimum torque reverse (OTR) motion, which is a torque-sensitive reciprocation. Instrumentation was completed without instrument fracture or ledge formation in all six groups. OTR-3N specimens displayed a significantly lower upward force (i.e., screw-in force) than OTR-2N specimens (p < 0.05). OTR-1N specimens required a significantly longer instrumentation time than CR-1N specimens and the other OTR specimens (p < 0.05). At 1 mm from the apex, CR-2N specimens showed a significantly larger canal-centering ratio (i.e., larger deviation) than OTR-2N specimens (p < 0.05). Overall, applying a downward load of 2–3 N in OTR mode provided shaping efficiency similar to CR, but with a reduced screw-in force and enhanced canal-centering in the apical region, supporting the use of OTR as a promising alternative to CR for curved canal preparation using heat-treated NiTi instruments.
- Open Access
Thermal Treatment Prevents Effects of Downward Loads on the Screw-In Force Generation and Canal-Centering Ability of Nickel–Titanium Rotary Instruments
This study aimed to examine how downward load applied during instrumentation affects the stress generation and shaping properties in thermally treated and non-treated NiTi rotary instruments. ProTaper Universal (PTU; non-thermally treated) and ProTaper Gold (PTG; thermally treated) were used to prepare J-shaped canals in resin blocks. Load-controlled automated instrumentation and torque/force sensing devices were employed with preset downward loads of 1, 2, or 3 N (n = 10 each). The torque/force, instrumentation time, and canal-centering ratio were measured and analyzed using two-way or one-way analysis of variance with Tukey’s test (α = 0.05). In the PTU-1N group, instrumentation was not completed because a ledge was formed in all canals. The PTU-3N group showed significantly greater upward force (screw-in force) and clockwise torque, along with a significantly smaller canal-centering ratio (less deviation) at the apical 0 mm level, than the PTU-2N group (p < 0.05). The downward load did not influence the instrumentation time (p > 0.05). In the PTG groups, these effects of downward load on the force generation and canal-centering ratio were not significant (p > 0.05). In the non-thermally treated PTU instruments, greater downward loads enhanced screw-in force while decreasing apical canal deviation; however, these effects were abolished in the thermally treated PTG instruments. This study highlights the importance of adapting the instrumentation technique with instrument characteristics: thermally treated flexible instruments facilitate smoother use, while stiffer, non-thermally treated ones may require precise control of downward loads.
Open AccessThermal Treatment Prevents Effects of Downward Loads on the Screw-In Force Generation and Canal-Centering Ability of Nickel–Titanium Rotary Instruments
This study aimed to examine how downward load applied during instrumentation affects the stress generation and shaping properties in thermally treated and non-treated NiTi rotary instruments. ProTaper Universal (PTU; non-thermally treated) and ProTaper Gold (PTG; thermally treated) were used to prepare J-shaped canals in resin blocks. Load-controlled automated instrumentation and torque/force sensing devices were employed with preset downward loads of 1, 2, or 3 N (n = 10 each). The torque/force, instrumentation time, and canal-centering ratio were measured and analyzed using two-way or one-way analysis of variance with Tukey’s test (α = 0.05). In the PTU-1N group, instrumentation was not completed because a ledge was formed in all canals. The PTU-3N group showed significantly greater upward force (screw-in force) and clockwise torque, along with a significantly smaller canal-centering ratio (less deviation) at the apical 0 mm level, than the PTU-2N group (p < 0.05). The downward load did not influence the instrumentation time (p > 0.05). In the PTG groups, these effects of downward load on the force generation and canal-centering ratio were not significant (p > 0.05). In the non-thermally treated PTU instruments, greater downward loads enhanced screw-in force while decreasing apical canal deviation; however, these effects were abolished in the thermally treated PTG instruments. This study highlights the importance of adapting the instrumentation technique with instrument characteristics: thermally treated flexible instruments facilitate smoother use, while stiffer, non-thermally treated ones may require precise control of downward loads.
- Open Access
- 31 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 15 (1) , 288
Impact of Varying Amplitudes of Upward and Downward Motion on the Torque/Force Generation, Canal-Centering Ability, and Cyclic Fatigue Resistance of Nickel–Titanium Reciprocating Instrument
The optimal amplitude of pecking motion during nickel–titanium rotary root canal instrumentation remains unclear. This study evaluated how different pecking amplitudes influence the force/torque generation, canal-centering ability, and cyclic fatigue resistance of the Reciproc Blue R25 instrument. Thirty J-shaped resin canals were instrumented with Reciproc Blue using automated instrumentation and a torque/force sensing device with an up-and-down speed of 50 mm/min and varying pecking amplitudes: Group S (1 s apically, 0.5 s coronally), Group M (2 s apically, 1 s coronally), and Group L (4 s apically, 2 s coronally) (n = 10 each). Force/torque were recorded, and canal-centering ratios were determined. In a dynamic cyclic fatigue test, the Reciproc Blue instruments were rotated in a curved metal canal with 1 mm or 3 mm back-and-forth motions (n = 10 each). Group L exhibited significantly greater maximum downward force and cumulative upward (screw-in) force than Group S (p < 0.05), but torque was not significantly different across groups. Groups M and L exhibited a significantly smaller canal-centering ratio than Group S (p < 0.05). Pecking at 3 mm led to a significantly longer time to fracture and shorter fragment lengths than 1 mm pecking (p < 0.05). In the Reciproc Blue instrumentation, higher pecking amplitude improved canal-centering ability and cyclic fatigue resistance while increasing upward and downward forces.
- 31 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 15 (1) , 288
Open AccessImpact of Varying Amplitudes of Upward and Downward Motion on the Torque/Force Generation, Canal-Centering Ability, and Cyclic Fatigue Resistance of Nickel–Titanium Reciprocating Instrument
The optimal amplitude of pecking motion during nickel–titanium rotary root canal instrumentation remains unclear. This study evaluated how different pecking amplitudes influence the force/torque generation, canal-centering ability, and cyclic fatigue resistance of the Reciproc Blue R25 instrument. Thirty J-shaped resin canals were instrumented with Reciproc Blue using automated instrumentation and a torque/force sensing device with an up-and-down speed of 50 mm/min and varying pecking amplitudes: Group S (1 s apically, 0.5 s coronally), Group M (2 s apically, 1 s coronally), and Group L (4 s apically, 2 s coronally) (n = 10 each). Force/torque were recorded, and canal-centering ratios were determined. In a dynamic cyclic fatigue test, the Reciproc Blue instruments were rotated in a curved metal canal with 1 mm or 3 mm back-and-forth motions (n = 10 each). Group L exhibited significantly greater maximum downward force and cumulative upward (screw-in) force than Group S (p < 0.05), but torque was not significantly different across groups. Groups M and L exhibited a significantly smaller canal-centering ratio than Group S (p < 0.05). Pecking at 3 mm led to a significantly longer time to fracture and shorter fragment lengths than 1 mm pecking (p < 0.05). In the Reciproc Blue instrumentation, higher pecking amplitude improved canal-centering ability and cyclic fatigue resistance while increasing upward and downward forces.
- Open Access
- 23 August 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-14
Effect of repetitive up-and-down movements on torque/force generation, surface defects and shaping ability of nickel-titanium rotary instruments: an ex vivo study
The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions. Therefore, this study aimed to examine how repeated up-and-down movements at the working length affect torque/force generation, surface defects, and canal shaping ability of JIZAI and TruNatomy instruments. An original automated root canal instrumentation device was used to prepare canals and to record torque/force changes. The mesial roots of human mandibular molars with approximately 30˚ of canal curvature were selected through geometric matching using micro-computed tomography. The samples were divided into three groups according to the number of up-and-down movements at the working length (1, 3, and 6 times; n = 24 each) and subdivided according to the instruments: JIZAI (#13/0.04 taper, #25/0.04 taper, and #35/0.04 taper) or TruNatomy (#17/0.02 taper, #26/0.04 taper, and #36/0.03 tape) (n = 12 each). The design, surface defects, phase transformation temperatures, nickel-titanium ratios, torque, force, shaping ability, and surface deformation were evaluated. Data were analyzed with the Kruskal-Wallis and Dunn’s tests (α = 0.05). The instruments had different designs and phase transformation temperatures. The 3 and 6 up-and-down movements resulted in a smaller upward force compared to 1 movement (p < 0.05). TruNatomy generated significantly less maximum torque, force, and surface wear than JIZAI (p < 0.05). However, TruNatomy exhibited a larger canal deviation (p < 0.05). No statistical differences in shaping ability were detected between different up-and-down movements. Under laboratory conditions with JIZAI and TruNatomy, a single up-and-down movement at the working length increased the screw-in force of subsequent instruments in severely curved canals in the single-length instrumentation technique. A single up-and-down movement generated more surface defects on the file when using JIZAI. TruNatomy resulted in less stress generation during instrumentation, while JIZAI better maintained the curvature of root canals.
- 23 August 2024
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-14
Open AccessEffect of repetitive up-and-down movements on torque/force generation, surface defects and shaping ability of nickel-titanium rotary instruments: an ex vivo study
The screw-in effect is a tendency of a nickel-titanium (NiTi) rotary endodontic file to be pulled into the canal, which can result in a sudden increase in stress leading to instrument fracture, and over-instrumentation beyond the apex. To reduce screw-in force, repeated up-and-down movements are recommended to distribute flexural stress during instrumentation, especially in curved and constricted canals. However, there is no consensus on the optimal number of repetitions. Therefore, this study aimed to examine how repeated up-and-down movements at the working length affect torque/force generation, surface defects, and canal shaping ability of JIZAI and TruNatomy instruments. An original automated root canal instrumentation device was used to prepare canals and to record torque/force changes. The mesial roots of human mandibular molars with approximately 30˚ of canal curvature were selected through geometric matching using micro-computed tomography. The samples were divided into three groups according to the number of up-and-down movements at the working length (1, 3, and 6 times; n = 24 each) and subdivided according to the instruments: JIZAI (#13/0.04 taper, #25/0.04 taper, and #35/0.04 taper) or TruNatomy (#17/0.02 taper, #26/0.04 taper, and #36/0.03 tape) (n = 12 each). The design, surface defects, phase transformation temperatures, nickel-titanium ratios, torque, force, shaping ability, and surface deformation were evaluated. Data were analyzed with the Kruskal-Wallis and Dunn’s tests (α = 0.05). The instruments had different designs and phase transformation temperatures. The 3 and 6 up-and-down movements resulted in a smaller upward force compared to 1 movement (p < 0.05). TruNatomy generated significantly less maximum torque, force, and surface wear than JIZAI (p < 0.05). However, TruNatomy exhibited a larger canal deviation (p < 0.05). No statistical differences in shaping ability were detected between different up-and-down movements. Under laboratory conditions with JIZAI and TruNatomy, a single up-and-down movement at the working length increased the screw-in force of subsequent instruments in severely curved canals in the single-length instrumentation technique. A single up-and-down movement generated more surface defects on the file when using JIZAI. TruNatomy resulted in less stress generation during instrumentation, while JIZAI better maintained the curvature of root canals.
- Open Access
- 30 October 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-10
Phase transformation and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures
Background: The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of different heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures.Methods: Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05).Results: DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, VB, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05).Conclusions: Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, especially in the NCF values of instruments with a mixture of martensite/R-phase and austenite phases at the tested temperatures.
- 30 October 2023
- Published by Springer Nature in BMC Oral Health
- Vol. 23 (1) , 1-10
Open AccessPhase transformation and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures
Background: The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of different heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures.Methods: Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05).Results: DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, VB, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05).Conclusions: Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, especially in the NCF values of instruments with a mixture of martensite/R-phase and austenite phases at the tested temperatures.
- Open Access
- 11 August 2023
- Published by Elsevier in Journal of Dental Sciences
- Vol. 19 (2) , 929-936
Phase transformation behavior and mechanical properties of HyFlex EDM nickel-titanium endodontic rotary instrument: Evaluation at body temperature
- 11 August 2023
- Published by Elsevier in Journal of Dental Sciences
- Vol. 19 (2) , 929-936
Open AccessPhase transformation behavior and mechanical properties of HyFlex EDM nickel-titanium endodontic rotary instrument: Evaluation at body temperature
- Open Access
- 19 July 2023
- Published by Springer Nature in Research Square
Temperature-dependent phase composition and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures
Background The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of differently heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures. Methods Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05). Results DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05). Conclusions Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, particularly in instruments composed of a mix of martensite/R-phase and austenite.
- 19 July 2023
- Published by Springer Nature in Research Square
Open AccessTemperature-dependent phase composition and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures
Background The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of differently heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures. Methods Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05). Results DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05). Conclusions Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, particularly in instruments composed of a mix of martensite/R-phase and austenite.