Cryo electron microscopy facilities running multiple instruments and serving users with varying skill levels need a robust and reliable method for benchmarking both the hardware and software components of their single particle analysis workflow. The workflow is complex, with many bottlenecks existing at the specimen preparation, data collection and image analysis steps; the samples and grid preparation can be of unpredictable quality, there are many different protocols for microscope and camera settings, and there is a myriad of software programs for analysis that can depend on dozens of settings chosen by the user. For this reason, we believe it is important to benchmark the entire workflow, using a standard sample and standard operating procedures, on a regular basis. This provides confidence that all aspects of the pipeline are capable of producing maps to high resolution. Here we describe benchmarking procedures using a test sample, rabbit muscle aldolase.Keywords
All Related Versions
Funding Information
- Simons Foundation (SF349247)
- National Institutes of Health (GM103310, S10 OD019994-01)
- Agouron Institute (F00316)
This publication has 22 references indexed in Scilit:
- 2.8 Å resolution reconstruction of the Thermoplasma acidophilum 20S proteasome using cryo-electron microscopyeLife, 2015
- Ultrastable gold substrates for electron cryomicroscopyScience, 2014
- Near-atomic resolution reconstructions using a mid-range electron microscope operated at 200kVJournal of Structural Biology, 2014
- High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopyUltramicroscopy, 2013
- Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EMNature Methods, 2013
- Prevention of overfitting in cryo-EM structure determinationNature Methods, 2012
- Outcome of the First Electron Microscopy Validation Task Force MeetingStructure, 2012
- Appion: An integrated, database-driven pipeline to facilitate EM image processingJournal of Structural Biology, 2009
- Automated molecular microscopy: The new Leginon systemJournal of Structural Biology, 2005
- FindEM—a fast, efficient program for automatic selection of particles from electron micrographsJournal of Structural Biology, 2004