Acetabular Liner Fixation by Cement
Authors:
- 1 December 2003
- journal article
- review article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 417 (417) , 217-223
Abstract
Many situations in revision THA require the exchange of a PE liner in the setting of a well-fixed cementless acetabular shell. Unfortunately, a replacement liner is not always available, the locking mechanism of the metal shell may be damaged or incompatible with the desired liner, or the shell is malpositioned. Revision of a well-fixed cementless acetabular shell has been associated with considerable morbidity. This raises several questions: can a new PE liner be fixed in the existing shell using bone cement, and if so, which techniques can improve the end result, and in which patients should they be used? Biomechanical testing of cemented PE liners has shown initial fixation strengths that exceed conventional locking mechanisms. It is not known during what period this initial fixation will fail, but clinical reports with followup of as many as 6 years have shown survival in approximately 90% of cases. These studies have shown the importance of proper patient selection, accurate sizing of the PE liner, careful preparation of the substrate of the liner and the shell, and good cement technique. The potential advantages of this technique are less surgical morbidity, more rapid surgery and patient recovery, the ability to incorporate antibiotics in the cement, and more liner options.Keywords
This publication has 26 references indexed in Scilit:
- Dislocation of the polyethylene liner in hip arthroplastyActa Orthopaedica, 2002
- The strength of a cement acetabular locking mechanismThe Journal of Arthroplasty, 2001
- Wear-Through of a Modular Polyethylene LinerClinical Orthopaedics and Related Research, 2001
- Mechanical Stability of Polyethylene Liners Cemented Into Acetabular ShellsCritical Reviews in Biomedical Engineering, 2000
- Severe polyethylene wear in uncemented acetabular cup system componentsThe Journal of Arthroplasty, 1999
- Acetabular fracture associated with cementless acetabular component insertionThe Journal of Arthroplasty, 1999
- Polyethylene wear and periprosthetic osteolysis in metal-backed acetabular components with cylindrical linersThe Journal of Arthroplasty, 1998
- Wear of the polyethylene liner—metallic shell interface in modular acetabular componentsThe Journal of Arthroplasty, 1996
- Severe polyethylene wear in total hip arthroplastyThe Journal of Arthroplasty, 1994
- Separation of the Polyethylene Liner From Acetabular Cup Metal BackingClinical Orthopaedics and Related Research, 1992