William A. Jiranek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William A. Jiranek has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
John R. Owen
3 shared publicationsAndrew R. Noble
2 shared publicationsBenjamin W. Cramer
Departments of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, P.O. Box 980694, Richmond, VA 23298. address for W.A. Jiranek
2 shared publicationsDaniel B. Branham
2 shared publicationsJennifer S. Wayne
2 shared publicationsMark C. Willis
Departments of Orthopaedic Surgery and Biomedical Engineering, Orthopaedic Research Laboratory, Virginia Commonwealth University, P.O. Box 980694, Richmond, VA 23298. address for W.A. Jiranek
2 shared publications
Latest Publications
- 30 June 2006
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 21 (4) , 606-611
Effect of Pigmentation on the Mechanical and Polymerization Characteristics of Bone Cement
- 30 June 2006
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 21 (4) , 606-611
Effect of Pigmentation on the Mechanical and Polymerization Characteristics of Bone Cement
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (3) , 521-529
MECHANICAL EFFECTS OF THE EXTENDED TROCHANTERIC OSTEOTOMY
Background: The extended trochanteric osteotomy was introduced as a safe and effective exposure technique for revision hip surgery; however, intraoperative iatrogenic femoral fractures have been reported. This study examined the effects of the extended trochanteric osteotomy on the torsional strength of the femur with use of cadaver bones. We hypothesized that repair of the osteotomy fragment would restore the torsional strength to that of an intact femur and that an osteotomized femur containing a well-fixed stem would have the same torsional strength as an intact femur with a stem. Methods: Fifty-eight cadaveric human femora were divided into five groups, according to the repair technique, to examine the effects of the extended trochanteric osteotomy: intact, osteotomy, repaired osteotomy, implant, and implant-repaired osteotomy. Osteotomy fragments were reattached with use of three double-looped 18-gauge wires. A femoral stem was cemented into the last two groups. Specimens were tested mechanically in rotation until failure. Rotational properties were compared with one-way analysis of variance followed by post hoc pairwise comparisons. Linear regression analysis was performed for bone mineral density and torsional strength. Results: Torque to failure was reduced by 73% for the specimens in the osteotomy group compared with the intact group (p < 0.0001). Repair of the osteotomy did not improve torque to failure (p > 0.99). Femora in the implant-repaired osteotomy group displayed significantly improved torque-to-failure values compared with the specimens in the osteotomy and repaired osteotomy groups (p < 0.0001). However, the strength of the femora in the implant-repaired osteotomy group remained significantly less than that of the specimens in the implant group (p < 0.007). A significant linear relationship was observed between bone mineral density and torque to failure for femora in the intact (p < 0.006), osteotomy (p < 0.002), and repaired osteotomy (p < 0.001) groups. Conclusions: The extended trochanteric osteotomy reduces torsional strength by 73% even when the osteotomy fragment is repaired. Bone mineral density directly affects absolute femoral strength in this model. Clinical Relevance: In this in vitro cadaver study, the extended trochanteric osteotomy resulted in a significant reduction of torsional strength and energy required for fracture. Femoral stem insertion with osteotomy repair significantly improved torsional strength; however, this construct remained significantly weaker than that of a femur that had an implant without an osteotomy. This finding suggests that postoperative rehabilitation protocols should be even more restrictive with regard to weight-bearing and the use of abduction braces after revisions with use of an extended trochanteric osteotomy than after revisions that do not require an extended trochanteric osteotomy.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (3) , 521-529
MECHANICAL EFFECTS OF THE EXTENDED TROCHANTERIC OSTEOTOMY
Background: The extended trochanteric osteotomy was introduced as a safe and effective exposure technique for revision hip surgery; however, intraoperative iatrogenic femoral fractures have been reported. This study examined the effects of the extended trochanteric osteotomy on the torsional strength of the femur with use of cadaver bones. We hypothesized that repair of the osteotomy fragment would restore the torsional strength to that of an intact femur and that an osteotomized femur containing a well-fixed stem would have the same torsional strength as an intact femur with a stem. Methods: Fifty-eight cadaveric human femora were divided into five groups, according to the repair technique, to examine the effects of the extended trochanteric osteotomy: intact, osteotomy, repaired osteotomy, implant, and implant-repaired osteotomy. Osteotomy fragments were reattached with use of three double-looped 18-gauge wires. A femoral stem was cemented into the last two groups. Specimens were tested mechanically in rotation until failure. Rotational properties were compared with one-way analysis of variance followed by post hoc pairwise comparisons. Linear regression analysis was performed for bone mineral density and torsional strength. Results: Torque to failure was reduced by 73% for the specimens in the osteotomy group compared with the intact group (p < 0.0001). Repair of the osteotomy did not improve torque to failure (p > 0.99). Femora in the implant-repaired osteotomy group displayed significantly improved torque-to-failure values compared with the specimens in the osteotomy and repaired osteotomy groups (p < 0.0001). However, the strength of the femora in the implant-repaired osteotomy group remained significantly less than that of the specimens in the implant group (p < 0.007). A significant linear relationship was observed between bone mineral density and torque to failure for femora in the intact (p < 0.006), osteotomy (p < 0.002), and repaired osteotomy (p < 0.001) groups. Conclusions: The extended trochanteric osteotomy reduces torsional strength by 73% even when the osteotomy fragment is repaired. Bone mineral density directly affects absolute femoral strength in this model. Clinical Relevance: In this in vitro cadaver study, the extended trochanteric osteotomy resulted in a significant reduction of torsional strength and energy required for fracture. Femoral stem insertion with osteotomy repair significantly improved torsional strength; however, this construct remained significantly weaker than that of a femur that had an implant without an osteotomy. This finding suggests that postoperative rehabilitation protocols should be even more restrictive with regard to weight-bearing and the use of abduction braces after revisions with use of an extended trochanteric osteotomy than after revisions that do not require an extended trochanteric osteotomy.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (3) , 521-529
Mechanical Effects of the Extended Trochanteric Osteotomy
Background: The extended trochanteric osteotomy was introduced as a safe and effective exposure technique for revision hip surgery; however, intraoperative iatrogenic femoral fractures have been reported. This study examined the effects of the extended trochanteric osteotomy on the torsional strength of the femur with use of cadaver bones. We hypothesized that repair of the osteotomy fragment would restore the torsional strength to that of an intact femur and that an osteotomized femur containing a well-fixed stem would have the same torsional strength as an intact femur with a stem. Methods: Fifty-eight cadaveric human femora were divided into five groups, according to the repair technique, to examine the effects of the extended trochanteric osteotomy: intact, osteotomy, repaired osteotomy, implant, and implant-repaired osteotomy. Osteotomy fragments were reattached with use of three double-looped 18-gauge wires. A femoral stem was cemented into the last two groups. Specimens were tested mechanically in rotation until failure. Rotational properties were compared with one-way analysis of variance followed by post hoc pairwise comparisons. Linear regression analysis was performed for bone mineral density and torsional strength. Results: Torque to failure was reduced by 73% for the specimens in the osteotomy group compared with the intact group (p < 0.0001). Repair of the osteotomy did not improve torque to failure (p > 0.99). Femora in the implant-repaired osteotomy group displayed significantly improved torque-to-failure values compared with the specimens in the osteotomy and repaired osteotomy groups (p < 0.0001). However, the strength of the femora in the implant-repaired osteotomy group remained significantly less than that of the specimens in the implant group (p < 0.007). A significant linear relationship was observed between bone mineral density and torque to failure for femora in the intact (p < 0.006), osteotomy (p < 0.002), and repaired osteotomy (p < 0.001) groups. Conclusions: The extended trochanteric osteotomy reduces torsional strength by 73% even when the osteotomy fragment is repaired. Bone mineral density directly affects absolute femoral strength in this model. Clinical Relevance: In this in vitro cadaver study, the extended trochanteric osteotomy resulted in a significant reduction of torsional strength and energy required for fracture. Femoral stem insertion with osteotomy repair significantly improved torsional strength; however, this construct remained significantly weaker than that of a femur that had an implant without an osteotomy. This finding suggests that postoperative rehabilitation protocols should be even more restrictive with regard to weight-bearing and the use of abduction braces after revisions with use of an extended trochanteric osteotomy than after revisions that do not require an extended trochanteric osteotomy.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (3) , 521-529
Mechanical Effects of the Extended Trochanteric Osteotomy
Background: The extended trochanteric osteotomy was introduced as a safe and effective exposure technique for revision hip surgery; however, intraoperative iatrogenic femoral fractures have been reported. This study examined the effects of the extended trochanteric osteotomy on the torsional strength of the femur with use of cadaver bones. We hypothesized that repair of the osteotomy fragment would restore the torsional strength to that of an intact femur and that an osteotomized femur containing a well-fixed stem would have the same torsional strength as an intact femur with a stem. Methods: Fifty-eight cadaveric human femora were divided into five groups, according to the repair technique, to examine the effects of the extended trochanteric osteotomy: intact, osteotomy, repaired osteotomy, implant, and implant-repaired osteotomy. Osteotomy fragments were reattached with use of three double-looped 18-gauge wires. A femoral stem was cemented into the last two groups. Specimens were tested mechanically in rotation until failure. Rotational properties were compared with one-way analysis of variance followed by post hoc pairwise comparisons. Linear regression analysis was performed for bone mineral density and torsional strength. Results: Torque to failure was reduced by 73% for the specimens in the osteotomy group compared with the intact group (p < 0.0001). Repair of the osteotomy did not improve torque to failure (p > 0.99). Femora in the implant-repaired osteotomy group displayed significantly improved torque-to-failure values compared with the specimens in the osteotomy and repaired osteotomy groups (p < 0.0001). However, the strength of the femora in the implant-repaired osteotomy group remained significantly less than that of the specimens in the implant group (p < 0.007). A significant linear relationship was observed between bone mineral density and torque to failure for femora in the intact (p < 0.006), osteotomy (p < 0.002), and repaired osteotomy (p < 0.001) groups. Conclusions: The extended trochanteric osteotomy reduces torsional strength by 73% even when the osteotomy fragment is repaired. Bone mineral density directly affects absolute femoral strength in this model. Clinical Relevance: In this in vitro cadaver study, the extended trochanteric osteotomy resulted in a significant reduction of torsional strength and energy required for fracture. Femoral stem insertion with osteotomy repair significantly improved torsional strength; however, this construct remained significantly weaker than that of a femur that had an implant without an osteotomy. This finding suggests that postoperative rehabilitation protocols should be even more restrictive with regard to weight-bearing and the use of abduction braces after revisions with use of an extended trochanteric osteotomy than after revisions that do not require an extended trochanteric osteotomy.
- 1 January 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 418 (418) , 172-178
Late Loosening of Press-Fit Cementless Acetabular Components
Between January 1987 and September 1990, 67 consecutive cementless total hip arthroplasties were implanted in 59 patients by one surgeon. The mean age of the patients at surgery was 57 years (range, 23–80 years). All acetabular components were plasma-sprayed titanium hemispheric cups with four peripheral rim fins, but additional screw fixation was not used. The mean followup was 10.4 years (range, 8.8–12.5 years). With revision as the endpoint, the failure rate of this acetabular component at a mean of 10.4 years was 28% (19/67). Of the 56 patients (56 hips) with radiographic followup, loosening of the acetabular shell occurred in 10 hips in 10 patients (18%). Seventy percent of these loosened cups failed by tilt which occurred in a rapid manner; all of the patients required revision surgery. We examined the manner of loosening of a press-fit acetabular component after early (5-year) results showed high hip scores and a low failure rate.
- 1 January 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 418 (418) , 172-178
Late Loosening of Press-Fit Cementless Acetabular Components
Between January 1987 and September 1990, 67 consecutive cementless total hip arthroplasties were implanted in 59 patients by one surgeon. The mean age of the patients at surgery was 57 years (range, 23–80 years). All acetabular components were plasma-sprayed titanium hemispheric cups with four peripheral rim fins, but additional screw fixation was not used. The mean followup was 10.4 years (range, 8.8–12.5 years). With revision as the endpoint, the failure rate of this acetabular component at a mean of 10.4 years was 28% (19/67). Of the 56 patients (56 hips) with radiographic followup, loosening of the acetabular shell occurred in 10 hips in 10 patients (18%). Seventy percent of these loosened cups failed by tilt which occurred in a rapid manner; all of the patients required revision surgery. We examined the manner of loosening of a press-fit acetabular component after early (5-year) results showed high hip scores and a low failure rate.
- 1 December 2003
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 417 (417) , 217-223
Acetabular Liner Fixation by Cement
Many situations in revision THA require the exchange of a PE liner in the setting of a well-fixed cementless acetabular shell. Unfortunately, a replacement liner is not always available, the locking mechanism of the metal shell may be damaged or incompatible with the desired liner, or the shell is malpositioned. Revision of a well-fixed cementless acetabular shell has been associated with considerable morbidity. This raises several questions: can a new PE liner be fixed in the existing shell using bone cement, and if so, which techniques can improve the end result, and in which patients should they be used? Biomechanical testing of cemented PE liners has shown initial fixation strengths that exceed conventional locking mechanisms. It is not known during what period this initial fixation will fail, but clinical reports with followup of as many as 6 years have shown survival in approximately 90% of cases. These studies have shown the importance of proper patient selection, accurate sizing of the PE liner, careful preparation of the substrate of the liner and the shell, and good cement technique. The potential advantages of this technique are less surgical morbidity, more rapid surgery and patient recovery, the ability to incorporate antibiotics in the cement, and more liner options.
- 1 December 2003
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 417 (417) , 217-223
Acetabular Liner Fixation by Cement
Many situations in revision THA require the exchange of a PE liner in the setting of a well-fixed cementless acetabular shell. Unfortunately, a replacement liner is not always available, the locking mechanism of the metal shell may be damaged or incompatible with the desired liner, or the shell is malpositioned. Revision of a well-fixed cementless acetabular shell has been associated with considerable morbidity. This raises several questions: can a new PE liner be fixed in the existing shell using bone cement, and if so, which techniques can improve the end result, and in which patients should they be used? Biomechanical testing of cemented PE liners has shown initial fixation strengths that exceed conventional locking mechanisms. It is not known during what period this initial fixation will fail, but clinical reports with followup of as many as 6 years have shown survival in approximately 90% of cases. These studies have shown the importance of proper patient selection, accurate sizing of the PE liner, careful preparation of the substrate of the liner and the shell, and good cement technique. The potential advantages of this technique are less surgical morbidity, more rapid surgery and patient recovery, the ability to incorporate antibiotics in the cement, and more liner options.