Limited Revision with a Newly Designed Hinge Device for the Treatment of Mega‐Prosthesis Hinge Failure: Two Case Reports
Open Access
- 3 June 2024
- journal article
- research article
- Published by Wiley in Orthopaedic Surgery
- Vol. 16 (7) , 1744-1750
Abstract
Background: Surgical treatment for hinge failure in mega‐prosthesis continues to be a challenge. This study introduces a new method for treating hinge failure by using a unilateral prosthesis and hinge revision.Case Presentation: We here present two patients who underwent mega‐prosthesis reconstruction after resection of osteosarcoma in the distal femur. To address the issue of knee hyperextension after mega‐prosthesis reconstruction, one patient underwent three revision surgeries, two surgeries were performed using the original hinge, and one surgery involved a newly designed hinge. To resolve the problem of dislocation, one patient underwent three revisions, with the first two revisions not involving hinge replacement and the third revision involving a newly designed hinge. Two replacements of unilateral prosthesis and hinge renovations were successful.Conclusions: Unilateral prosthesis and newly designed hinge device revision are effective in treating the failure of old‐fashioned mega‐prosthesis hinges.Keywords
This publication has 28 references indexed in Scilit:
- Limb salvage surgery reconstructive techniques following long‐bone lower limb oncological resection: a systematic review and meta‐analysisAnz Journal of Surgery, 2023
- Radiographic Assessment of Aseptic Loosening of Tumor‐Type Knee Prosthesis in Distal FemurOrthopaedic Surgery, 2022
- What is the Cumulative Incidence of Revision Surgery and What Are the Complications Associated With Stemmed Cementless Nonextendable Endoprostheses in Patients 18 Years or Younger With Primary Bone Sarcomas About the KneeClinical Orthopaedics and Related Research, 2022
- Molded, Gamma-radiated, Argon-processed Polyethylene Components of Rotating Hinge Knee Megaprostheses Have a Lower Failure Hazard and Revision Rates Than Air-sterilized, Machined, Ram-extruded Bar Stock ComponentsClinical Orthopaedics and Related Research, 2020
- Guideline for Limb‐Salvage Treatment of OsteosarcomaOrthopaedic Surgery, 2020
- Early Mechanical Failure of a Tumoral Endoprosthesic Rotating Hinge in the Knee: Does Bumper Wear Contribute to Hyperextension Failure?Clinical Orthopaedics and Related Research, 2019
- Structural Failure of a Modern Knee Tumor MegaendoprosthesisCase Reports in Orthopedics, 2017
- Evaluation of Stability of Rotating Hinge Knee Prostheses: A Biomechanical StudyISRN Orthopedics, 2013
- Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literatureInternational Orthopaedics, 2011
- Revision of Broken Knee Megaprostheses: New Solution to Old ProblemsClinical Orthopaedics and Related Research, 2010