Electroenzymatic choline sensing at near the theoretical performance limit
- 8 December 2020
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 1040-1047
Abstract
A high performance, electroenzymatic microsensor for choline based on choline oxidase (ChOx) immobilized on Pt coated with permselective polymer layers has been created that exhibits sensitivity approaching the theoretical performance limit. Sensor construction was guided by simulations performed with a detailed mathematical model. Implantable microsensors with an array of electroenzymatic sensing sites provide a means to record concentration changes of choline, an effective surrogate for acetylcholine due to its very rapid turnover in the brain, and other neurochemicals in vivo. However, electroenzymatic sensors generally have insufficient sensitivity and response time to monitor neurotransmitter signaling on the millisecond timescale with cellular-level spatial resolution. Model simulations suggested that choline sensor performance can be improved significantly by optimizing immobilized ChOx layer thickness and minimizing the thicknesses of permselective polymer coatings as well. Electroenzymatic choline sensors constructed with a ∼5 μm-thick crosslinked ChOx layer atop 200 nm-thick permselective films (poly(m-phenylenediamine) and Nafion) exhibited unprecedented sensitivity and response time of 660 ± 40 nA μM−1 cm−2 at 37 °C and 0.36 ± 0.05 s, respectively, while maintaining excellent selectivity. Such performance characteristics provide greater flexibility in the design of microelectrode array (MEA) probes with near cellular-scale sensing sites arranged in more dense arrays. Also, faster response times enable better resolution of transient acetylcholine signals and better correlation of these events with electrophysiological recordings so as to advance study of brain function.Keywords
Funding Information
- National Institute of Neurological Disorders and Stroke (R01NS087494)
This publication has 41 references indexed in Scilit:
- Continuous Online Microdialysis Using Microfluidic Sensors: Dynamic Neurometabolic Changes during Spreading DepolarizationACS Chemical Neuroscience, 2013
- Optimizing the Temporal Resolution of Fast-Scan Cyclic VoltammetryACS Chemical Neuroscience, 2012
- Multiplexed, High Density Electrophysiology with Nanofabricated Neural ProbesPLOS ONE, 2011
- Collection, storage, and electrophoretic analysis of nanoliter microdialysis samples collected from awake animals in vivoAnalytical and Bioanalytical Chemistry, 2011
- Silicon Wafer-Based Platinum Microelectrode Array Biosensor for Near Real-Time Measurement of Glutamate in VivoSensors, 2008
- Prefrontal Acetylcholine Release Controls Cue Detection on Multiple TimescalesNeuron, 2007
- Chronic second‐by‐second measures of l‐glutamate in the central nervous system of freely moving ratsJournal of Neurochemistry, 2007
- Second‐by‐second measurement of acetylcholine release in prefrontal cortexEuropean Journal of Neuroscience, 2006
- Dynamic Changes in Brain Glucose and Lactate in Pericontusional Areas of the Human Cerebral Cortex, Monitored with Rapid Sampling On-Line Microdialysis: Relationship with Depolarisation-Like EventsJournal of Cerebral Blood Flow & Metabolism, 2005
- Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part 1. An adsorption-controlled mechanismElectrochimica Acta, 1998