Movement characteristics in young patients and the impact on CBCT image quality
- 1 April 2016
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 45 (4) , 20150426
Abstract
Objective:To assess patient movement characteristics in children and young adults and the impact on CBCT image quality.Methods:During 33 CBCT examinations, the patient (age average 14 years; range 9-25) had moved, identified by video observation (Movement group, MG). The CBCT datasets were matched with those of 33 non-moving patients according to age, diagnostic task, examined region, field-of-view, and voxel resolution (Non-movement group, N-MG). Three observers scored the videos MG regarding motional state second-by-second (moving/non-moving), and movement characteristics: duration (seconds), complexity (uniplanar or multiplanar), and distance (10mm). The observers blindly assessed axial sections of the 66 examinations individually, categorizing image quality (appropriate/acceptable/inappropriate). Next, the observers blindly assessed axial sections of the matched-pairs images simultaneously, deciding which image in the pair had the higher image quality, or if it was impossible to decide. The ...Keywords
This publication has 19 references indexed in Scilit:
- Factors affecting patient movement and re-exposure in cone beam computed tomography examinationOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2015
- Radiographic observers' ability to recognize patient movement during cone beam CTDentomaxillofacial Radiology, 2014
- Movement of the patient and the cone beam computed tomography scanner: objectives and possible solutionsOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2013
- Cone beam CT image artefacts related to head motion simulated by a robot skull: visual characteristics and impact on image qualityDentomaxillofacial Radiology, 2013
- Dose distribution for dental cone beam CT and its implication for defining a dose indexDentomaxillofacial Radiology, 2012
- Effective dose range for dental cone beam computed tomography scannersEuropean Journal of Radiology, 2012
- Estimated pediatric radiation dose during CTPediatric Radiology, 2011
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- Reduction of the negative influence of patient motion on quality of CBCT scanMedical Hypotheses, 2010
- Conebeam CT of the Head and Neck, Part 1: Physical PrinciplesAmerican Journal of Neuroradiology, 2009