Lars Schropp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lars Schropp has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Ann Wenzel
Oral Radiology, Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark
14 shared publications- Rubens Spin-Neto
Section for Oral Radiology and Endodontics, Department of Dentistry and Oral Health Aarhus University Aarhus Denmark
13 shared publications - Ann Wenzel
Section for Oral Radiology, Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark
9 shared publications Lambros Kostopoulos
6 shared publicationsAndreas Stavropoulos
Department of Periodontology and Community Dentistry Malmö University Malmö Sweden
5 shared publicationsFlemming Isidor
Prosthetic Dentistry Department of Dentistry Aarhus University Aarhus C Denmark
5 shared publications
Latest Publications
- Open Access
- 22 March 2024
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 83, 20-29
Longitudinal study of endodontic and periapical status of an adult Danish population examined in 2009, 2014, and 2019: a repeated cohort study
Objective: To describe endodontic changes in an adult Danish population (C2;2009–2014–2019) and compare them with a similar cohort (C1;1997–2003–2008). Material and methods: A randomly selected cohort (C2) with three full-mouth radiographic examinations. The frequencies of teeth, apical periodontitis (AP), root filled teeth, and lost teeth in C2 were compared to a similar cohort (C1) using regression analyses; effect of age, cohort, and period was assessed. Results: C1 had 330 and C2, 170 participants (mean age, C1: 42.9; C2: 47.3 years, p < .001). The proportion of individuals with no AP was similar in C1 and C2 (p = .46). C2 had a higher proportion of individuals with no root filled teeth (p < .001) and no tooth loss (p = .02) than C1. The proportion of AP and root filled teeth increased with age in both cohorts. C2 had fewer root filled teeth and lost teeth, fewest lost teeth in the youngest age groups. Conclusions: In C2, the prevalence of teeth with AP and root fillings increased with age, and few teeth were lost. Change in proportion of AP was similar in two cohorts; fewer root filled teeth and lost teeth in C2. The proportion of lost teeth in C2 showed cohort effect for older age groups.
- 22 March 2024
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 83, 20-29
Open AccessLongitudinal study of endodontic and periapical status of an adult Danish population examined in 2009, 2014, and 2019: a repeated cohort study
Objective: To describe endodontic changes in an adult Danish population (C2;2009–2014–2019) and compare them with a similar cohort (C1;1997–2003–2008). Material and methods: A randomly selected cohort (C2) with three full-mouth radiographic examinations. The frequencies of teeth, apical periodontitis (AP), root filled teeth, and lost teeth in C2 were compared to a similar cohort (C1) using regression analyses; effect of age, cohort, and period was assessed. Results: C1 had 330 and C2, 170 participants (mean age, C1: 42.9; C2: 47.3 years, p < .001). The proportion of individuals with no AP was similar in C1 and C2 (p = .46). C2 had a higher proportion of individuals with no root filled teeth (p < .001) and no tooth loss (p = .02) than C1. The proportion of AP and root filled teeth increased with age in both cohorts. C2 had fewer root filled teeth and lost teeth, fewest lost teeth in the youngest age groups. Conclusions: In C2, the prevalence of teeth with AP and root fillings increased with age, and few teeth were lost. Change in proportion of AP was similar in two cohorts; fewer root filled teeth and lost teeth in C2. The proportion of lost teeth in C2 showed cohort effect for older age groups.
- 1 October 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (7)
Effect of computer-assisted-learning and simulation clinics on dental students’ cognitive and performance skills: panoramic image errors related to patient’s head position
Objectives: To assess dental students’ ability to recognize head positioning errors in panoramic (PAN) images after individual learning via computer-assisted-learning (CAL) and in a simulation clinic (SIM). Both cognitive skills and performance in patient examination were assessed. Methods and materials: 60 students (mean age 23.25 years) participated in lectures on the relation between PAN-image errors and patient’s head position. Immediately after they took a test, based on which they were randomized to three groups: control (CON) group, CAL group, and SIM group (both CAL and training in a simulation clinic with a phantom). 4–5 weeks after intervention/no intervention, all students individually examined a patient with PAN-exposure. A blinded rater, not knowing group allocation, supervised patient exposure and assessed student’s performance (correct/incorrect head position in three planes). 1–2 weeks after, the students scored positioning errors in 40 PAN-images. Differences in cognitive test scores between groups were evaluated by ANOVA and in patient examination by χ2 tests, and within-group differences by sign-tests. Results: No statistically significant difference in cognitive test scores was seen between the SIM and CAL group, while the CON group scored lower (p < 0.003). In all groups, several students positioned the patient incorrectly in the Frankfort horizontal plane. All students performed well in the sagittal plane. Students in SIM group positioned the patient more correctly in the coronal plane. Conclusions: Training with CAL increased students’ cognitive skills compared with a control group. Simulated patient exposure with a phantom increased to some extent their performance skills in examination of patients.
- 1 October 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (7)
Effect of computer-assisted-learning and simulation clinics on dental students’ cognitive and performance skills: panoramic image errors related to patient’s head position
Objectives: To assess dental students’ ability to recognize head positioning errors in panoramic (PAN) images after individual learning via computer-assisted-learning (CAL) and in a simulation clinic (SIM). Both cognitive skills and performance in patient examination were assessed. Methods and materials: 60 students (mean age 23.25 years) participated in lectures on the relation between PAN-image errors and patient’s head position. Immediately after they took a test, based on which they were randomized to three groups: control (CON) group, CAL group, and SIM group (both CAL and training in a simulation clinic with a phantom). 4–5 weeks after intervention/no intervention, all students individually examined a patient with PAN-exposure. A blinded rater, not knowing group allocation, supervised patient exposure and assessed student’s performance (correct/incorrect head position in three planes). 1–2 weeks after, the students scored positioning errors in 40 PAN-images. Differences in cognitive test scores between groups were evaluated by ANOVA and in patient examination by χ2 tests, and within-group differences by sign-tests. Results: No statistically significant difference in cognitive test scores was seen between the SIM and CAL group, while the CON group scored lower (p < 0.003). In all groups, several students positioned the patient incorrectly in the Frankfort horizontal plane. All students performed well in the sagittal plane. Students in SIM group positioned the patient more correctly in the coronal plane. Conclusions: Training with CAL increased students’ cognitive skills compared with a control group. Simulated patient exposure with a phantom increased to some extent their performance skills in examination of patients.
- 1 September 2020
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 8 (5) , 896
Timing of Thoracic Outlet Decompression After Thrombolysis for Primary Upper Extremity Deep Venous Thrombosis: A Systematic Review
- 1 September 2020
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 8 (5) , 896
Timing of Thoracic Outlet Decompression After Thrombolysis for Primary Upper Extremity Deep Venous Thrombosis: A Systematic Review
- 1 March 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (3) , 20190315
Image-stitching artefacts and distortion in CCD-based cephalograms and their association with sensor type and head movement: ex vivo study
To assess presence and severity of image-stitching artefacts and distortion in lateral cephalograms acquired by CCD-based sensors and their association with movement. A human skull was mounted on a robot simulating five head movement types (antero posterior translation/lifting/nodding/lateral rotation/tremor), at three distances (0.75/1.5/3 mm), based on two patterns (skull returning/not returning to the initial position, except for tremor). Three cephalometric units, two ProMax-2D (Planmeca Oy, Finland), one with Dimax-3 (D-3) and one with Dimax-4 (D-4) sensor, and one Orthophos-SL (ORT, Dentsply-Sirona, Germany), acquired cephalograms during the predetermined movements, in duplicate (54 with movement, and 28 controls with no movement per unit). One observer assessed the presence of an image-stitching line (none/thin/thin with vertical stripes or thick), misalignment between the anatomical structure display (none/3 mm), and distortion in each image quadrant (present/absent), in duplicate. Severe image-stitching artefacts were defined for images scored with a thin line with vertical stripes or thick line and/or misalignment between anatomical structure display ≥1 mm. Severe distortion was defined for images scored with distortion in both anterior quadrants of the skull. Kappa-statistics provided intra observer agreement. Intra observer reproducibility was >0.8 (all assessed parameters). Severe image-stitching artefacts were scored in 70.4 and 18.5% of D-3 and D-4 movement images, respectively. Severe distortion was scored in 64.8% of D-3, 5.6% of D-4, and 37% of ORT movement images. Neither severe image-stitching artefacts nor severe distortion were observed in control images. Sensor type, movement type, distance, and pattern affected presence and severity of image-stitching artefacts and distortion in CCD-based cephalograms.
- 1 March 2020
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 49 (3) , 20190315
Image-stitching artefacts and distortion in CCD-based cephalograms and their association with sensor type and head movement: ex vivo study
To assess presence and severity of image-stitching artefacts and distortion in lateral cephalograms acquired by CCD-based sensors and their association with movement. A human skull was mounted on a robot simulating five head movement types (antero posterior translation/lifting/nodding/lateral rotation/tremor), at three distances (0.75/1.5/3 mm), based on two patterns (skull returning/not returning to the initial position, except for tremor). Three cephalometric units, two ProMax-2D (Planmeca Oy, Finland), one with Dimax-3 (D-3) and one with Dimax-4 (D-4) sensor, and one Orthophos-SL (ORT, Dentsply-Sirona, Germany), acquired cephalograms during the predetermined movements, in duplicate (54 with movement, and 28 controls with no movement per unit). One observer assessed the presence of an image-stitching line (none/thin/thin with vertical stripes or thick), misalignment between the anatomical structure display (none/3 mm), and distortion in each image quadrant (present/absent), in duplicate. Severe image-stitching artefacts were defined for images scored with a thin line with vertical stripes or thick line and/or misalignment between anatomical structure display ≥1 mm. Severe distortion was defined for images scored with distortion in both anterior quadrants of the skull. Kappa-statistics provided intra observer agreement. Intra observer reproducibility was >0.8 (all assessed parameters). Severe image-stitching artefacts were scored in 70.4 and 18.5% of D-3 and D-4 movement images, respectively. Severe distortion was scored in 64.8% of D-3, 5.6% of D-4, and 37% of ORT movement images. Neither severe image-stitching artefacts nor severe distortion were observed in control images. Sensor type, movement type, distance, and pattern affected presence and severity of image-stitching artefacts and distortion in CCD-based cephalograms.
- 1 February 2020
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 129 (2) , 158-164
Prevalence and severity of image-stitching artifacts in charge-coupled device–based cephalograms of orthodontic patients
- 1 February 2020
- Published by Elsevier in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
- Vol. 129 (2) , 158-164
Prevalence and severity of image-stitching artifacts in charge-coupled device–based cephalograms of orthodontic patients
- 1 December 2019
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 48 (8) , 20190209
Impact of CBCT on treatment decision related to surgical removal of impacted maxillary third molars: does CBCT change the surgical approach?
Objectives: To assess factors influencing treatment decision for maxillary third molars referred for cone beam CT (CBCT). Parameters influencing the decision to treat and to remove either the maxillary second molar or third molar were pursued. Methods: 111 impacted maxillary third molars, clinically examined including a panoramic image, in 86 patients (mean age 26 years, range 15–55) were referred for CBCT on suspicion of pathology/root resorption in the second molar, based on information in the panoramic image. The following parameters were assessed from the patient’s file, including the radiographic images: (1) third molar angulation; (2) initial treatment plan based on clinical examination and the panoramic image; (3) diagnoses based on information from CBCT; (4) treatment decision after additional CBCT information was available; (5) pre-/post-operative complications; (6) treatment of the maxillary second molar. Results: 70 cases (63.1%) underwent treatment, while 41 (36.9%) received no treatment. Change in treatment plan was registered in 65 cases (58.6%) after CBCT. In 12 cases (10.8%), treatment changed from removal of the third to removal of the second molar, while 25 (22.5%) were scheduled for removal in the initial treatment plan; but after CBCT, the decision was not to treat. If external root resorption involved the pulp of the second molar, there was an almost 17 times higher risk that this tooth was removed instead of the third molar (logistic regression analysis: odds ratio 16.8; p < 0.001). Conclusions: Findings in CBCT often changed the treatment plan. Severe external root resorption observed in CBCT was the main decisive factor for removing the second instead of the third molar.
- 1 December 2019
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 48 (8) , 20190209
Impact of CBCT on treatment decision related to surgical removal of impacted maxillary third molars: does CBCT change the surgical approach?
Objectives: To assess factors influencing treatment decision for maxillary third molars referred for cone beam CT (CBCT). Parameters influencing the decision to treat and to remove either the maxillary second molar or third molar were pursued. Methods: 111 impacted maxillary third molars, clinically examined including a panoramic image, in 86 patients (mean age 26 years, range 15–55) were referred for CBCT on suspicion of pathology/root resorption in the second molar, based on information in the panoramic image. The following parameters were assessed from the patient’s file, including the radiographic images: (1) third molar angulation; (2) initial treatment plan based on clinical examination and the panoramic image; (3) diagnoses based on information from CBCT; (4) treatment decision after additional CBCT information was available; (5) pre-/post-operative complications; (6) treatment of the maxillary second molar. Results: 70 cases (63.1%) underwent treatment, while 41 (36.9%) received no treatment. Change in treatment plan was registered in 65 cases (58.6%) after CBCT. In 12 cases (10.8%), treatment changed from removal of the third to removal of the second molar, while 25 (22.5%) were scheduled for removal in the initial treatment plan; but after CBCT, the decision was not to treat. If external root resorption involved the pulp of the second molar, there was an almost 17 times higher risk that this tooth was removed instead of the third molar (logistic regression analysis: odds ratio 16.8; p < 0.001). Conclusions: Findings in CBCT often changed the treatment plan. Severe external root resorption observed in CBCT was the main decisive factor for removing the second instead of the third molar.
- Open Access
- 22 March 2018
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 47 (5) , 20180013
An ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability
Objectives:To assess the impact of head motion artefacts and an automated artefact-correction system on CBCT image quality and interpretability for simulated diagnostic tasks.Methods:A partially dentate human skull was mounted on a robot simulating four types of head movement (antero-posterior translation, nodding, lateral rotation, and tremor), at three distances (0.75, 1.5, and 3 mm) based on two movement patterns (skull returning/not returning to the initial position). Two diagnostic tasks were simulated: dental implant planning and detection of a periapical lesion. Three CBCT units were used to examine the skull during the movements and no-motion (control): Cranex 3Dx (CRA), Orthophos SL 3D (ORT), and X1 without (X1wo) and with (X1wi) an automated motion artefact-correction system. For each diagnostic task, 88 examinations were performed. Three observers, blinded to unit and movement, scored image quality: presence of stripe artefacts (present/absent), overall unsharpness (present/absent), and image i...
- 22 March 2018
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 47 (5) , 20180013
Open AccessAn ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability
Objectives:To assess the impact of head motion artefacts and an automated artefact-correction system on CBCT image quality and interpretability for simulated diagnostic tasks.Methods:A partially dentate human skull was mounted on a robot simulating four types of head movement (antero-posterior translation, nodding, lateral rotation, and tremor), at three distances (0.75, 1.5, and 3 mm) based on two movement patterns (skull returning/not returning to the initial position). Two diagnostic tasks were simulated: dental implant planning and detection of a periapical lesion. Three CBCT units were used to examine the skull during the movements and no-motion (control): Cranex 3Dx (CRA), Orthophos SL 3D (ORT), and X1 without (X1wo) and with (X1wi) an automated motion artefact-correction system. For each diagnostic task, 88 examinations were performed. Three observers, blinded to unit and movement, scored image quality: presence of stripe artefacts (present/absent), overall unsharpness (present/absent), and image i...
- 1 February 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (2) , 20160289
Detection of patient movement during CBCT examination using video observation compared with an accelerometer-gyroscope tracking system
To compare video observation (VO) with a novel three-dimensional registration method, based on an accelerometer-gyroscope (AG) system, to detect patient movement during CBCT examination. The movements were further analyzed according to complexity and patient age. In 181 patients (118 females/63 males; age average 30 years, range: 9–84 years), 206 CBCT examinations were performed, which were video-recorded during examination. An AG was, at the same time, attached to the patient head to track head position in three dimensions. Three observers scored patient movement (yes/no) by VO. AG provided movement data on the x-, y- and z-axes. Thresholds for AG-based registration were defined at 0.5, 1, 2, 3 and 4 mm (movement distance). Movement detected by VO was compared with that registered by AG, according to movement complexity (uniplanar vs multiplanar, as defined by AG) and patient age (≤15, 16–30 and ≥31 years). According to AG, movement ≥0.5 mm was present in 160 (77.7%) examinations. According to VO, movement was present in 46 (22.3%) examinations. One VO-detected movement was not registered by AG. Overall, VO did not detect 71.9% of the movements registered by AG at the 0.5-mm threshold. At a movement distance ≥4 mm, 20% of the AG-registered movements were not detected by VO. Multiplanar movements such as lateral head rotation (72.1%) and nodding/swallowing (52.6%) were more often detected by VO in comparison with uniplanar movements, such as head lifting (33.6%) and anteroposterior translation (35.6%), at the 0.5-mm threshold. The prevalence of patients who move was highest in patients younger than 16 years (64.3% for VO and 92.3% for AG-based registration at the 0.5-mm threshold). AG-based movement registration resulted in a higher prevalence of patient movement during CBCT examination than VO-based registration. Also, AG-registered multiplanar movements were more frequently detected by VO than uniplanar movements. The prevalence of patients who move was highest in patients younger than 16 years.
- 1 February 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (2) , 20160289
Detection of patient movement during CBCT examination using video observation compared with an accelerometer-gyroscope tracking system
To compare video observation (VO) with a novel three-dimensional registration method, based on an accelerometer-gyroscope (AG) system, to detect patient movement during CBCT examination. The movements were further analyzed according to complexity and patient age. In 181 patients (118 females/63 males; age average 30 years, range: 9–84 years), 206 CBCT examinations were performed, which were video-recorded during examination. An AG was, at the same time, attached to the patient head to track head position in three dimensions. Three observers scored patient movement (yes/no) by VO. AG provided movement data on the x-, y- and z-axes. Thresholds for AG-based registration were defined at 0.5, 1, 2, 3 and 4 mm (movement distance). Movement detected by VO was compared with that registered by AG, according to movement complexity (uniplanar vs multiplanar, as defined by AG) and patient age (≤15, 16–30 and ≥31 years). According to AG, movement ≥0.5 mm was present in 160 (77.7%) examinations. According to VO, movement was present in 46 (22.3%) examinations. One VO-detected movement was not registered by AG. Overall, VO did not detect 71.9% of the movements registered by AG at the 0.5-mm threshold. At a movement distance ≥4 mm, 20% of the AG-registered movements were not detected by VO. Multiplanar movements such as lateral head rotation (72.1%) and nodding/swallowing (52.6%) were more often detected by VO in comparison with uniplanar movements, such as head lifting (33.6%) and anteroposterior translation (35.6%), at the 0.5-mm threshold. The prevalence of patients who move was highest in patients younger than 16 years (64.3% for VO and 92.3% for AG-based registration at the 0.5-mm threshold). AG-based movement registration resulted in a higher prevalence of patient movement during CBCT examination than VO-based registration. Also, AG-registered multiplanar movements were more frequently detected by VO than uniplanar movements. The prevalence of patients who move was highest in patients younger than 16 years.
- 1 January 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (1) , 20160330
Radiographic signs of pathology determining removal of an impacted mandibular third molar assessed in a panoramic image or CBCT
Objectives:To (1) compare pathological findings related to the mandibular third molar in panoramic images (PAN) and CBCT; (2) estimate the frequency of removals if pathological findings were indicative; and (3) assess factors in PAN associated with resorption and marginal bone loss at the second molar as observed in CBCT.Methods:379 mandibular third molars were examined with PAN and CBCT. Four observers registered resorption and marginal bone loss at the second molar and increased periodontal space at the third molar in both imaging modalities. Agreement between PAN and CBCT, frequency of removals based on pathological findings in either of the two modalities and interobserver reproducibility was calculated. Logistic regression analyses assessed factors in PAN, which could predict marginal bone loss and resorption observed in CBCT.Results:Agreement between PAN and CBCT: resorption 54–74%; marginal bone loss 66–85%; and increased periodontal space 92–97%. Removals based on CBCT and PAN: 58–71% and 36–65%. ...
- 1 January 2017
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 46 (1) , 20160330
Radiographic signs of pathology determining removal of an impacted mandibular third molar assessed in a panoramic image or CBCT
Objectives:To (1) compare pathological findings related to the mandibular third molar in panoramic images (PAN) and CBCT; (2) estimate the frequency of removals if pathological findings were indicative; and (3) assess factors in PAN associated with resorption and marginal bone loss at the second molar as observed in CBCT.Methods:379 mandibular third molars were examined with PAN and CBCT. Four observers registered resorption and marginal bone loss at the second molar and increased periodontal space at the third molar in both imaging modalities. Agreement between PAN and CBCT, frequency of removals based on pathological findings in either of the two modalities and interobserver reproducibility was calculated. Logistic regression analyses assessed factors in PAN, which could predict marginal bone loss and resorption observed in CBCT.Results:Agreement between PAN and CBCT: resorption 54–74%; marginal bone loss 66–85%; and increased periodontal space 92–97%. Removals based on CBCT and PAN: 58–71% and 36–65%. ...