Automatic Normal Positioning of Robotic Ultrasound Probe Based Only on Confidence Map Optimization and Force Measurement
- 20 January 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 1342-1349
Abstract
Acquiring good image quality is one of the main challenges for fully-automatic robot-assisted ultrasound systems (RUSS). The presented method aims at overcoming this challenge for orthopaedic applications by optimizing the orientation of the robotic ultrasound (US) probe, i.e. aligning the central axis of the US probe to the tissue's surface normal at the point of contact in order to improve sound propagation within the tissue. We first optimize the in-plane orientation of the probe by analyzing the confidence map [1] of the US image. We then carry out a fan motion and analyze the resulting forces estimated from joint torques to align the central axis of the probe to the normal within the plane orthogonal to the initial image plane. This results in the final 3D alignment of the probe's main axis with the normal to the anatomical surface at the point of contact without using external sensors for surface reconstruction or localizing the point of contact in an anatomical atlas. The algorithm is evaluated both on a phantom and on human tissues (forearm, upper arm and lower back). The mean absolute angular difference ( $\pm$ STD) between true and estimated normal on stationary phantom, forearm, upper arm and lower back was $3.1 \pm 1.0^\circ$ , $3.7 \pm 1.7^\circ$ , $5.3\pm 1.3^\circ$ and $6.9 \pm 3.5^\circ$ , respectively. In comparison, six human operators obtained errors of 3.2 \pm 1.7^\circ on the phantom. Hence the method is able to automatically position the probe normal to the scanned tissue at the point of contact and thus improve the quality of automatically acquired ultrasound images.
Keywords
This publication has 18 references indexed in Scilit:
- A Comparative Study on the Influence of Probe Placement on Quality Assurance Measurements in B-mode Ultrasound by Means of Ultrasound PhantomsThe Open Biomedical Engineering Journal, 2015
- Tracked “Pick-Up” Ultrasound for Robot-Assisted Minimally Invasive SurgeryIEEE Transactions on Biomedical Engineering, 2015
- Force and Position Control System for Freehand UltrasoundIEEE Transactions on Robotics, 2015
- Automatic bone detection and soft tissue aware ultrasound–CT registration for computer-aided orthopedic surgeryInternational Journal of Computer Assisted Radiology and Surgery, 2015
- Interface Design and Control Strategies for a Robot Assisted Ultrasonic Examination System2014
- Ultrasound confidence maps using random walksMedical Image Analysis, 2012
- Ultraschallkriterien zur Graduierung von Stenosen der A. carotis interna – Revision der DEGUM-Kriterien und Transfer in NASCET-StenosierungsgradeUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Ultrasound: Basic understanding and learning the languageInternational Journal of Shoulder Surgery, 2010
- Hippocrate: a safe robot arm for medical applications with force feedbackMedical Image Analysis, 1999
- The elastic moduli of human subchondral, trabecular, and cortical bone tissue and the size-dependency of cortical bone modulusJournal of Biomechanics, 1990