WSWalter Simson
Walter Simson
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Walter Simson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Guillaume Zahnd
Technische Universität München
1 shared publication- Guillaume Zahnd
Thera Medical GmbH, Munich, Germany
1 shared publication - Javier Esteban
Technical University of Munich, 9184 Munchen, Bayern, Germany
1 shared publication - Magdalini Paschali
Stanford Center for Artificial Intelligence in Medicine and Imaging, Stanford University, Stanford, USA
1 shared publication - Matthias Grimm
Department of General, Visceral, and Transplantation Surgery, Hospital of the LMU Munich, Ludwig-Maximilians-Universität (LMU), Munich, Germany
1 shared publication - Mingchuan Zhou
Robotic Micro-nano Manipulation Lab, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, China
1 shared publication
Latest Publications
- 20 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 1342-1349
Automatic Normal Positioning of Robotic Ultrasound Probe Based Only on Confidence Map Optimization and Force Measurement
Acquiring good image quality is one of the main challenges for fully-automatic robot-assisted ultrasound systems (RUSS). The presented method aims at overcoming this challenge for orthopaedic applications by optimizing the orientation of the robotic ultrasound (US) probe, i.e. aligning the central axis of the US probe to the tissue's surface normal at the point of contact in order to improve sound propagation within the tissue. We first optimize the in-plane orientation of the probe by analyzing the confidence map [1] of the US image. We then carry out a fan motion and analyze the resulting forces estimated from joint torques to align the central axis of the probe to the normal within the plane orthogonal to the initial image plane. This results in the final 3D alignment of the probe's main axis with the normal to the anatomical surface at the point of contact without using external sensors for surface reconstruction or localizing the point of contact in an anatomical atlas. The algorithm is evaluated both on a phantom and on human tissues (forearm, upper arm and lower back). The mean absolute angular difference ( $\pm$ STD) between true and estimated normal on stationary phantom, forearm, upper arm and lower back was $3.1 \pm 1.0^\circ$ , $3.7 \pm 1.7^\circ$ , $5.3\pm 1.3^\circ$ and $6.9 \pm 3.5^\circ$ , respectively. In comparison, six human operators obtained errors of 3.2 \pm 1.7^\circ on the phantom. Hence the method is able to automatically position the probe normal to the scanned tissue at the point of contact and thus improve the quality of automatically acquired ultrasound images.- 20 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 5 (2) , 1342-1349
Automatic Normal Positioning of Robotic Ultrasound Probe Based Only on Confidence Map Optimization and Force Measurement
Acquiring good image quality is one of the main challenges for fully-automatic robot-assisted ultrasound systems (RUSS). The presented method aims at overcoming this challenge for orthopaedic applications by optimizing the orientation of the robotic ultrasound (US) probe, i.e. aligning the central axis of the US probe to the tissue's surface normal at the point of contact in order to improve sound propagation within the tissue. We first optimize the in-plane orientation of the probe by analyzing the confidence map [1] of the US image. We then carry out a fan motion and analyze the resulting forces estimated from joint torques to align the central axis of the probe to the normal within the plane orthogonal to the initial image plane. This results in the final 3D alignment of the probe's main axis with the normal to the anatomical surface at the point of contact without using external sensors for surface reconstruction or localizing the point of contact in an anatomical atlas. The algorithm is evaluated both on a phantom and on human tissues (forearm, upper arm and lower back). The mean absolute angular difference ( $\pm$ STD) between true and estimated normal on stationary phantom, forearm, upper arm and lower back was $3.1 \pm 1.0^\circ$ , $3.7 \pm 1.7^\circ$ , $5.3\pm 1.3^\circ$ and $6.9 \pm 3.5^\circ$ , respectively. In comparison, six human operators obtained errors of 3.2 \pm 1.7^\circ on the phantom. Hence the method is able to automatically position the probe normal to the scanned tissue at the point of contact and thus improve the quality of automatically acquired ultrasound images.- Open Access
- 7 February 2019
- Published by Springer Nature
- p. 257
Abstract: Beamforming Sub-Sampled Raw Ultrasound Data with DeepFormer
- 7 February 2019
- Published by Springer Nature
- p. 257
Open AccessAbstract: Beamforming Sub-Sampled Raw Ultrasound Data with DeepFormer