Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report
Open Access
- 24 August 2022
- journal article
- research article
- Published by Wiley in Clinical Case Reports
- Vol. 10 (8) , e6248
Abstract
Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability.Keywords
This publication has 24 references indexed in Scilit:
- A retrospective multicenter case series evaluating a novel 3.0-mm expanding tapered body implant for the rehabilitation of missing incisors.2016
- Clinical and radiographic evaluation of narrow‐ vs. regular‐diameter dental implants: a 3‐year follow‐up. A retrospective studyClinical Oral Implants Research, 2013
- Immediate provisionalization of 3.0-mm-diameter implants replacing single missing maxillary and mandibular incisors: 1-year prospective study.2012
- Application of a narrow-diameter implant in a limited spaceJournal of Dental Sciences, 2010
- Outcome Evaluation of Early Placed Maxillary Anterior Single‐Tooth Implants Using Objective Esthetic Criteria: A Cross‐Sectional, Retrospective Study in 45 Patients With a 2‐ to 4‐Year Follow‐Up Using Pink and White Esthetic ScoresJournal of Periodontology, 2009
- Clinical Outcome of Narrow Diameter Implants: A Retrospective Study of 510 ImplantsJournal of Periodontology, 2008
- Evaluation of soft tissue around single‐tooth implant crowns: the pink esthetic scoreClinical Oral Implants Research, 2005
- Influence of implant diameters on the integration of screw implantsInternational Journal of Oral and Maxillofacial Surgery, 1997
- Tissue integration of non‐submerged implants. l‐year results of a prospective study with 100 ITI hollow‐cylinder and hollow‐screw implants.Clinical Oral Implants Research, 1990
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981