Sergio Rocha Bernardes
Research Subjects
Sergio Rocha Bernardes has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Geninho Thomé
Faculdade Ilapeo, Brasil
8 shared publications - Larissa Carvalho Trojan
Faculdade Ilapeo, Brasil
5 shared publications - Jean Uhlendorf
Neodent Curitiba Brazil
4 shared publications - Carolina Accorsi Cartelli
Neodent Curitiba Brazil
3 shared publications - Camila Pereira Vianna
Curitiba, Brazil
2 shared publications - Marcos Boaventura de Moura
Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Av. Pará 1720, Bloco 4LB, sala 39, Uberlandia, MG, 38405-902, Brazil
2 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (11) , 712
Five- to Nine-Year Clinical and Radiographic Performance of Morse-Tapered Hybrid Dental Implants: A Retrospective Observational Study
Background/Objectives: The long-term clinical performance of Morse-tapered hybrid dental implants remains insufficiently documented. This retrospective cohort study evaluated implant, prosthesis, and abutment survival, marginal bone loss (MBL), and the influence of implant- and patient-related variables over a follow-up period of up to 108 months. Methods: Patients who received Morse-tapered hybrid dental implants between 2017 and 2020 and had at least 5 years of follow-up were retrospectively evaluated. Implant, prosthesis, and abutment survival, as well as radiographic MBL, were assessed. MBL was determined using standardized periapical radiographs obtained from baseline to 108 months. Kaplan–Meier survival analysis and log-rank tests were used to evaluate survival outcomes, whereas longitudinal MBL was analyzed using linear mixed-effects models accounting for clustering at the patient level. Results: A total of 367 Helix GM® implants placed in 79 patients (mean age: 53.5 ± 13.4 years) were included, with follow-up ranging from 60 to 108 months. Cumulative implant survival was 99.2% at 108 months, with all implant failures occurring within the first year of function. Prosthesis survival ranged from 90.0% to 95.8%, and abutment survival ranged from 99.1% to 100%. Mean MBL remained below 1.0 mm throughout long-term follow-up. Implant survival and MBL were not significantly influenced by insertion torque, bone quality, loading protocol, or prosthetic rehabilitation design (p > 0.05). Smoking and depression were associated with implant failure in the study cohort (p < 0.05). Conclusions: Within the limitations of this retrospective, single-center cohort, the evaluated Morse-tapered hybrid dental implant system demonstrated favorable long-term clinical and radiographic performance, with high implant survival, favorable prosthetic outcomes, and limited marginal bone loss over up to 108 months of function. Implant survival and marginal bone stability were not significantly influenced by insertion torque, bone quality, loading protocol, or prosthetic rehabilitation design under the clinical conditions evaluated. These findings should be interpreted within the context of the specific implant system, clinical setting, and patient population investigated.
- 3 November 2026
- Published by MDPI AG in Dentistry Journal
- Vol. 14 (11) , 712
Open AccessFive- to Nine-Year Clinical and Radiographic Performance of Morse-Tapered Hybrid Dental Implants: A Retrospective Observational Study
Background/Objectives: The long-term clinical performance of Morse-tapered hybrid dental implants remains insufficiently documented. This retrospective cohort study evaluated implant, prosthesis, and abutment survival, marginal bone loss (MBL), and the influence of implant- and patient-related variables over a follow-up period of up to 108 months. Methods: Patients who received Morse-tapered hybrid dental implants between 2017 and 2020 and had at least 5 years of follow-up were retrospectively evaluated. Implant, prosthesis, and abutment survival, as well as radiographic MBL, were assessed. MBL was determined using standardized periapical radiographs obtained from baseline to 108 months. Kaplan–Meier survival analysis and log-rank tests were used to evaluate survival outcomes, whereas longitudinal MBL was analyzed using linear mixed-effects models accounting for clustering at the patient level. Results: A total of 367 Helix GM® implants placed in 79 patients (mean age: 53.5 ± 13.4 years) were included, with follow-up ranging from 60 to 108 months. Cumulative implant survival was 99.2% at 108 months, with all implant failures occurring within the first year of function. Prosthesis survival ranged from 90.0% to 95.8%, and abutment survival ranged from 99.1% to 100%. Mean MBL remained below 1.0 mm throughout long-term follow-up. Implant survival and MBL were not significantly influenced by insertion torque, bone quality, loading protocol, or prosthetic rehabilitation design (p > 0.05). Smoking and depression were associated with implant failure in the study cohort (p < 0.05). Conclusions: Within the limitations of this retrospective, single-center cohort, the evaluated Morse-tapered hybrid dental implant system demonstrated favorable long-term clinical and radiographic performance, with high implant survival, favorable prosthetic outcomes, and limited marginal bone loss over up to 108 months of function. Implant survival and marginal bone stability were not significantly influenced by insertion torque, bone quality, loading protocol, or prosthetic rehabilitation design under the clinical conditions evaluated. These findings should be interpreted within the context of the specific implant system, clinical setting, and patient population investigated.
- Open Access
- 28 November 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (12) , 1305
Retrospective Cohort Study of 4783 Morse Taper Hybrid Dental Implants: Survival Rate Analysis
This retrospective study aimed to evaluate the survival rate of hybrid dental implants in different patient profiles and clinical conditions. A total of 1215 patients’ files were analyzed from patients with at least one hybrid dental implant inserted at ILAPEO College (Curitiba, Brazil) from 2018 to 2024. The data collection was performed from 2021 to 2024. Parameters related to patients, implants, and surgical characteristics were collected. Descriptive summary statistics were estimated for all parameters. The associations between the dependent variables “implant survival” and patient, procedure, and implant characteristics were assessed by the Cox proportional hazards model. A total of 4783 hybrid dental implants (Helix, GM, Neodent) were placed in 1215 patients with a mean age of 57.17 ± 12.09 years. The most frequent patients’ medical conditions were diabetes, hypertension, thyroid dysfunction, use of steroids (corticoids), psychological limitations, and bruxism and clenching. Patients were followed for a mean period of 29.54 ± 18.95 months. Immediate loading was applied in 2302 (48.13%) implants and conventional loading in 1735 (36.27%). One hundred and fifty-one implants were lost due to a lack of osseointegration, resulting in an implant survival rate of 95.4% (CI: 94.4%; 96.6%). Adverse events were reported in 389 (8.13%) implants. Uncontrolled hypertension, hypertension without information on control, absence of final abutment, replacement implant, and adverse event occurrence were associated with implant loss. Treatment using a hybrid macrogeometry dental implant is an option for total or partial edentulous patients with compromised health and different clinical conditions.
- 28 November 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (12) , 1305
Open AccessRetrospective Cohort Study of 4783 Morse Taper Hybrid Dental Implants: Survival Rate Analysis
This retrospective study aimed to evaluate the survival rate of hybrid dental implants in different patient profiles and clinical conditions. A total of 1215 patients’ files were analyzed from patients with at least one hybrid dental implant inserted at ILAPEO College (Curitiba, Brazil) from 2018 to 2024. The data collection was performed from 2021 to 2024. Parameters related to patients, implants, and surgical characteristics were collected. Descriptive summary statistics were estimated for all parameters. The associations between the dependent variables “implant survival” and patient, procedure, and implant characteristics were assessed by the Cox proportional hazards model. A total of 4783 hybrid dental implants (Helix, GM, Neodent) were placed in 1215 patients with a mean age of 57.17 ± 12.09 years. The most frequent patients’ medical conditions were diabetes, hypertension, thyroid dysfunction, use of steroids (corticoids), psychological limitations, and bruxism and clenching. Patients were followed for a mean period of 29.54 ± 18.95 months. Immediate loading was applied in 2302 (48.13%) implants and conventional loading in 1735 (36.27%). One hundred and fifty-one implants were lost due to a lack of osseointegration, resulting in an implant survival rate of 95.4% (CI: 94.4%; 96.6%). Adverse events were reported in 389 (8.13%) implants. Uncontrolled hypertension, hypertension without information on control, absence of final abutment, replacement implant, and adverse event occurrence were associated with implant loss. Treatment using a hybrid macrogeometry dental implant is an option for total or partial edentulous patients with compromised health and different clinical conditions.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 71, e20230031
Three-dimensional finite element analysis of three internal tapered implant-abutment designs
Objective: The aim of this study was to compare the stress distribution in internal tapered connection implants with different adaptation geometries submitted to oblique load simulation using the Finite Element Analysis (FEA) method. Methods: Three different internal tapered implant-abutment assemblies were modeled by varying only the diameter of the abutment body in the cone region. The dimensions of the implants were 4.0 mm in diameter and 13 mm in length. Oblique loads of 210 N angled 30 degrees to the long axis of the implant were applied to a hemispherical body positioned over the abutments simulating a dental crown. The stress generated by the implant-abutment assembly was analyzed by the FEA method using the von Mises criterion. Results: A higher concentration of stress in the coronal region (collar) and implant body on the opposite side of the load application was shown, as well as in the body region of the abutments and in the screw threads. The cervical region of the implants showed the highest von Mises stress values, the highest values being observed in G3 (1034 MPa), followed by G2 (841 MPa) and G1 (702 MPa). Conclusion: According to the results presented, it can be concluded that the stress distribution was more homogeneous and less concentrated in the G1 implant-abutment assembly. Therefore, the use of abutments with dimensions standardized by the implant manufacturer is recommended.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 71, e20230031
Open AccessThree-dimensional finite element analysis of three internal tapered implant-abutment designs
Objective: The aim of this study was to compare the stress distribution in internal tapered connection implants with different adaptation geometries submitted to oblique load simulation using the Finite Element Analysis (FEA) method. Methods: Three different internal tapered implant-abutment assemblies were modeled by varying only the diameter of the abutment body in the cone region. The dimensions of the implants were 4.0 mm in diameter and 13 mm in length. Oblique loads of 210 N angled 30 degrees to the long axis of the implant were applied to a hemispherical body positioned over the abutments simulating a dental crown. The stress generated by the implant-abutment assembly was analyzed by the FEA method using the von Mises criterion. Results: A higher concentration of stress in the coronal region (collar) and implant body on the opposite side of the load application was shown, as well as in the body region of the abutments and in the screw threads. The cervical region of the implants showed the highest von Mises stress values, the highest values being observed in G3 (1034 MPa), followed by G2 (841 MPa) and G1 (702 MPa). Conclusion: According to the results presented, it can be concluded that the stress distribution was more homogeneous and less concentrated in the G1 implant-abutment assembly. Therefore, the use of abutments with dimensions standardized by the implant manufacturer is recommended.
- Open Access
- 24 August 2022
- Published by Wiley in Clinical Case Reports
- Vol. 10 (8) , e6248
Clinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report
Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability.
- 24 August 2022
- Published by Wiley in Clinical Case Reports
- Vol. 10 (8) , e6248
Open AccessClinical and radiographic outcomes of maxillary lateral incisors rehabilitation using Morse taper connection extra‐narrow implants at 12‐month follow‐up: A case report
Narrow‐diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one‐year outcomes of extra‐narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26‐year‐old male patient in need of fixed‐implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all‐ceramic prostheses 12 months after surgery. The 1 year follow‐up showed clinical and radiographic success of extra‐narrow implant rehabilitation. Also, both regions presented good evolution of peri‐implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow‐up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra‐narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra‐narrow implant predictability.
- Open Access
- 4 December 2021
- Published by Wiley in Clinical Case Reports
- Vol. 9 (12) , e05118
Clinical and radiographic success of injection‐molded 2‐piece zirconia implants submitted to immediate loading: A 12‐month report of two cases
This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection‐molded 2‐piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri‐implantitis signs, complete implant osseointegration, good marginal bone‐level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.
- 4 December 2021
- Published by Wiley in Clinical Case Reports
- Vol. 9 (12) , e05118
Open AccessClinical and radiographic success of injection‐molded 2‐piece zirconia implants submitted to immediate loading: A 12‐month report of two cases
This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection‐molded 2‐piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri‐implantitis signs, complete implant osseointegration, good marginal bone‐level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.
- 14 September 2020
- Published by Revista Odontologica do Brasil Central - ROBRAC in Revista Odontológica do Brasil Central
- Vol. 29 (88)
Simplificação da técnica para reabilitação de maxila atrófica com implantes zigomáticos com interface cônica interna e carregamento imediato: relato de caso
A reabilitação de maxilas atróficas com implantes dentários é sempre um desafio, visto que o uso de enxertos ósseos é quase sempre necessário para estabilização dos implantes. Os implantes zigomáticos têm sido utilizados como uma opção viável ao uso de procedimentos de enxertia óssea anterior à cirurgia. A interface cônica interna apresenta gap reduzido entre implante e componente protético, mostrando resultados biológicos e estéticos satisfatórios a longo prazo. Este artigo tem como objetivo relatar a reabilitação protética imediata de uma maxila atrófica com implantes convencionais e zigomáticos com interface cônica interna como opção ao uso de enxertos ósseos prévios. Paciente com 47 anos de idade, do sexo masculino, apresentava maxila atrófica e usava uma prótese total superior. O paciente foi reabilitado com quatro implantes convencionais na região anterior e dois implantes zigomáticos cônicos internos instalados nos ossos zigomáticos. Os torques de instalação dos implantes ≥ 60 N.cm proporcionaram estabilidade primária ideal e uma prótese (protocolo) foi instalada imediatamente utilizando a técnica do assentamento passivo. O caso clínico apresentado mostrou que, após 1 ano, resultados precisos e estéticos são possíveis de alcançar com a instalação de implantes zigomáticos combinados com implantes convencionais para reabilitação de maxilas atróficas de forma imediata e sem utilização de enxerto ósseos prévios.
- 14 September 2020
- Published by Revista Odontologica do Brasil Central - ROBRAC in Revista Odontológica do Brasil Central
- Vol. 29 (88)
Simplificação da técnica para reabilitação de maxila atrófica com implantes zigomáticos com interface cônica interna e carregamento imediato: relato de caso
A reabilitação de maxilas atróficas com implantes dentários é sempre um desafio, visto que o uso de enxertos ósseos é quase sempre necessário para estabilização dos implantes. Os implantes zigomáticos têm sido utilizados como uma opção viável ao uso de procedimentos de enxertia óssea anterior à cirurgia. A interface cônica interna apresenta gap reduzido entre implante e componente protético, mostrando resultados biológicos e estéticos satisfatórios a longo prazo. Este artigo tem como objetivo relatar a reabilitação protética imediata de uma maxila atrófica com implantes convencionais e zigomáticos com interface cônica interna como opção ao uso de enxertos ósseos prévios. Paciente com 47 anos de idade, do sexo masculino, apresentava maxila atrófica e usava uma prótese total superior. O paciente foi reabilitado com quatro implantes convencionais na região anterior e dois implantes zigomáticos cônicos internos instalados nos ossos zigomáticos. Os torques de instalação dos implantes ≥ 60 N.cm proporcionaram estabilidade primária ideal e uma prótese (protocolo) foi instalada imediatamente utilizando a técnica do assentamento passivo. O caso clínico apresentado mostrou que, após 1 ano, resultados precisos e estéticos são possíveis de alcançar com a instalação de implantes zigomáticos combinados com implantes convencionais para reabilitação de maxilas atróficas de forma imediata e sem utilização de enxerto ósseos prévios.
- Open Access
- 1 January 2020
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 68
Guided osteotomy and implants placed with free hands for double full arch rehabilitation with immediate prosthetic loading
Precise planning for dental implant placement requires appreciation of anatomical limitations and restorative purpose. Diagnosis can be made by complementary exams such as panoramic radiography and cone-beam computed tomography. The purpose of this study was to rehabilitate the upper and lower jaw of a patient with severe periodontal disease using a guided osteotomy and implants placed with free hands and Morse taper implants. The concept of guided surgery was used to prepare the alveolar bone to place eight implants, four implants in the upper jaw and four implants in the lower jaw, all have achieved a minimum torque of 60 Ncm. The modified suture technique was used to better stabilize the soft tissue around the mini conical abutments. The analogues were scanned by CAD/CAM for confection of the metallic structures of the bridges. On the third day, the upper and lower full arch prostheses were installed and simultaneous bilateral contacts were adjusted. After 12 months of patient follow-up, the implants and prostheses were in good condition of aesthetics and function, maintaining the success of the rehabilitation. Within the limitations of this clinical case, it can be concluded that the implants placed with free hands was facilitated by a previous guided osteotomy.
- 1 January 2020
- Published by FapUNIFESP (SciELO) in RGO - Revista Gaúcha de Odontologia
- Vol. 68
Open AccessGuided osteotomy and implants placed with free hands for double full arch rehabilitation with immediate prosthetic loading
Precise planning for dental implant placement requires appreciation of anatomical limitations and restorative purpose. Diagnosis can be made by complementary exams such as panoramic radiography and cone-beam computed tomography. The purpose of this study was to rehabilitate the upper and lower jaw of a patient with severe periodontal disease using a guided osteotomy and implants placed with free hands and Morse taper implants. The concept of guided surgery was used to prepare the alveolar bone to place eight implants, four implants in the upper jaw and four implants in the lower jaw, all have achieved a minimum torque of 60 Ncm. The modified suture technique was used to better stabilize the soft tissue around the mini conical abutments. The analogues were scanned by CAD/CAM for confection of the metallic structures of the bridges. On the third day, the upper and lower full arch prostheses were installed and simultaneous bilateral contacts were adjusted. After 12 months of patient follow-up, the implants and prostheses were in good condition of aesthetics and function, maintaining the success of the rehabilitation. Within the limitations of this clinical case, it can be concluded that the implants placed with free hands was facilitated by a previous guided osteotomy.
- Open Access
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Morse taper implant macrodesign, loading protocol and site of installation – retrospective study of 5,601 implants
Introduction The long-term implant-supported prosthetic rehabilitation monitoring is extremely important in evaluating parameters that could interfere in the success of the treatment. Objective To evaluate the influence of macrodesign (shape of the body and apex), length and diameter, insertion torque, site of installation as well as the loading protocol, on long-term survival rates. Material and method The data obtained was from the medical records of rehabilitated patients who had had at least one Morse taper implant surgery done at ILAPEO School between 2006 -2012. Incomplete medical records, from which it would have been impossible to extract all data essential to complete the study, were excluded. Result A total of 1,142 patient’s medical records comprised the sample; documenting the progress of 5,601 implants, done in both jaws and mandibles. The final survival rate was 98.31%, over an average time of 37.54 months. The type of implant most used was cylindrical (70.33%). The mean installation torque most evidenced in the study was between 41 and 50 Ncm. A logistical regression analysis showed that none of the following variables, site of installation, body and apex shape designs and length, had any significant statistical influence on implant loss. Torque increase and diameter influenced implant loss while immediate loading favored implant maintenance. Conclusion It can be concluded that Morse taper implants present a long-term survival rate that can be lowered by excessive torque, as well as by the diameter of the implant.
- 1 January 2019
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 48
Open AccessMorse taper implant macrodesign, loading protocol and site of installation – retrospective study of 5,601 implants
Introduction The long-term implant-supported prosthetic rehabilitation monitoring is extremely important in evaluating parameters that could interfere in the success of the treatment. Objective To evaluate the influence of macrodesign (shape of the body and apex), length and diameter, insertion torque, site of installation as well as the loading protocol, on long-term survival rates. Material and method The data obtained was from the medical records of rehabilitated patients who had had at least one Morse taper implant surgery done at ILAPEO School between 2006 -2012. Incomplete medical records, from which it would have been impossible to extract all data essential to complete the study, were excluded. Result A total of 1,142 patient’s medical records comprised the sample; documenting the progress of 5,601 implants, done in both jaws and mandibles. The final survival rate was 98.31%, over an average time of 37.54 months. The type of implant most used was cylindrical (70.33%). The mean installation torque most evidenced in the study was between 41 and 50 Ncm. A logistical regression analysis showed that none of the following variables, site of installation, body and apex shape designs and length, had any significant statistical influence on implant loss. Torque increase and diameter influenced implant loss while immediate loading favored implant maintenance. Conclusion It can be concluded that Morse taper implants present a long-term survival rate that can be lowered by excessive torque, as well as by the diameter of the implant.
- 1 June 2017
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 43 (3) , 175-179
Fracture Strength of Standard and Small Diameter Prosthetic Abutments for Full-Arch Implant-Supported Restorations
This study tested the fracture strength of prosthetic abutments with different sizes and combinations to support a 5-implant milled framework with distal extension. Prosthetic abutments with different dimensions (4.8-mm diameter mini conical abutment and 3.5-mm diameter microconical abutment) were screwed to 5 threaded implants. The following groups were divided (n = 3): G1 with 5 miniconical abutments (standard size), G2 with 5 microconical abutments (small sized), G3 with a combination of 3 small sized abutments and 2 standard sized abutments, and G4 with a combination of 2 small sized abutments and 3 standard sized abutments. Standardized titanium frameworks for full-arch fixed dental prosthesis were milled with equidistant holes for each of the 5 implants and abutments. A loading point was selected at 18 mm away from both distal implants. A universal testing system was used for the fracture strength tests and load was applied at a crosshead speed of 0.5 mm/min on the previously described loading points until component fracture. Mean fracture strength for each group was statistically compared (α = 0.05). Prosthetic screws were the only fractured components for all tested groups. Mean fracture strength was: G1, 1130.22 N; G2, 1031.36 N; G3, 757.9 N; and G4 792.03 N (P < .05). All prosthetic abutments and combinations that were tested provide adequate fracture strength for clinical use. However, the combination of standard and small diameter abutments leads to lower fracture strength compared with when only standard sized prosthetic abutments were used, irrespective of the abutment diameter (4.8- or 3.5-mm).
- 1 June 2017
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 43 (3) , 175-179
Fracture Strength of Standard and Small Diameter Prosthetic Abutments for Full-Arch Implant-Supported Restorations
This study tested the fracture strength of prosthetic abutments with different sizes and combinations to support a 5-implant milled framework with distal extension. Prosthetic abutments with different dimensions (4.8-mm diameter mini conical abutment and 3.5-mm diameter microconical abutment) were screwed to 5 threaded implants. The following groups were divided (n = 3): G1 with 5 miniconical abutments (standard size), G2 with 5 microconical abutments (small sized), G3 with a combination of 3 small sized abutments and 2 standard sized abutments, and G4 with a combination of 2 small sized abutments and 3 standard sized abutments. Standardized titanium frameworks for full-arch fixed dental prosthesis were milled with equidistant holes for each of the 5 implants and abutments. A loading point was selected at 18 mm away from both distal implants. A universal testing system was used for the fracture strength tests and load was applied at a crosshead speed of 0.5 mm/min on the previously described loading points until component fracture. Mean fracture strength for each group was statistically compared (α = 0.05). Prosthetic screws were the only fractured components for all tested groups. Mean fracture strength was: G1, 1130.22 N; G2, 1031.36 N; G3, 757.9 N; and G4 792.03 N (P < .05). All prosthetic abutments and combinations that were tested provide adequate fracture strength for clinical use. However, the combination of standard and small diameter abutments leads to lower fracture strength compared with when only standard sized prosthetic abutments were used, irrespective of the abutment diameter (4.8- or 3.5-mm).