An integrated multichannel system for air-coupled CMUT array imaging and guided wave detection applications

Authors:

Abstract
Capacitive micromachined ultrasonic transducers (CMUTs) made by MEMS process have become a new choice for air-coupled ultrasonic transducers due to their high sensitivity, low acoustic impedance and easy arraying. At present, in the air coupling application of CMUT transducer, due to the weak signal strength of single element, the CMUT array usually works in a whole piece, limiting the advantage of the array. Therefore, a multi-channel air-coupled CMUT imaging system with high-voltage DC bias and low-noise high-gain current signal amplification is designed to realize the electronic scanning of our CMUT arrays. The imaging system has 16 transmit and receive channels, and each channel consists of pulse transmitting circuit, AC/DC coupling circuit, impedance matching circuit, low-noise transimpedance amplification circuit, controllable gain amplification circuit and AD circuit. The imaging chain and element control method of our CMUT array were developed to realize the electronic scanning imaging of air-coupled ultrasound. The feasibility of the system for non-destructive testing was also verified via the Lamb wave detection in a metal plate.…

This publication has 10 references indexed in Scilit: