Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs
- 27 October 2023
- journal article
- research article
- Published by Springer Nature in Advances in Therapy
- Vol. 41 (1) , 231-245
Abstract
Introduction This study investigated patient satisfaction levels in five premium intraocular lenses (IOLs). A secondary aim was to determine whether patient satisfaction was associated with the cataract grade before lens surgery. Methods In this multicenter prospective comparative study, 164 patients from diverse backgrounds underwent cataract surgery and were assigned for identical bilateral implantation of multifocal IOLs. In addition to visual performance, quality of life was measured using the National Eye Institute Refractive Error Quality Of Life Instrument (NEI-RQL 42) scoring questionnaire. The Sirius Scheimpflug Analyzer was used to evaluate the posterior cornea and aberrations. Finally, the association of patient satisfaction reports with the Pentacam Cataract Grading Scale (PCGS) and Lens Opacities Classification System (LOCS III) was evaluated. Results A considerable subjective improvement was observed in uncorrected far, near (40 cm), and intermediate (60 cm) visual acuity in the five groups (P values < 0.001). A significant difference was observed in mesopic and photopic contrast sensitivity between Symfony, Trinova, and AT LISA at the spatial frequency of 12 cycles per degree, favoring Symfony (P < 0.001). PanOptix users had considerably lower mean coma values (P < 0.001), while AT LISA users had lower mean spherical aberrations (P = 0.009) compared to the other groups. No additional safety concerns relating to IOLs were recorded. Mean satisfaction had a high correlation with LOCS and Pentacam Nuclear Staging (PNS) in each lens group, e.g., correlation coefficient and P value for AT LISA were respectively r = 0.99, P < 0.001 and r = 0.97, P = 0.004. Conclusion Despite discrepancies between groups of lenses, most patients who received multifocal IOLs reported satisfaction at more than 3 years after the initial operation. A growing number of patients with cataracts are seeking spectacle-free vision with presbyopia-correcting IOLs. Hence, the high satisfaction rate among patients with cataract could indicate the value of offering a wider range of available lenses.Keywords
This publication has 38 references indexed in Scilit:
- Intraocular lens optics and aberrationsCurrent Opinion in Ophthalmology, 2016
- Bilateral implantation of +2.5 D multifocal intraocular lens and contralateral implantation of +2.5 D and +3.0 D multifocal intraocular lenses: Clinical outcomesJournal of Cataract & Refractive Surgery, 2016
- Visual Function after Implantation of a Diffractive Aspheric Trifocal Intraocular LensEuropean Journal of Ophthalmology, 2016
- Trifocal Intraocular Lens Implantation to Treat Visual Demands in Various Distances Following Lens RemovalAmerican Journal of Ophthalmology, 2016
- Index of contrast sensitivity (ICS) in pseudophakic eyes with different intraocular lens designsActa Ophthalmologica, 2014
- Effect of an aspheric intraocular lens on the ocular wave‐front adjusted for pupil size and capsulorhexis sizeActa Ophthalmologica, 2014
- Multifocal intraocular lenses in cataract surgery: Literature review of benefits and side effectsJournal of Cataract & Refractive Surgery, 2013
- Dissatisfaction after implantation of multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2011
- Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a +3.0 D additionJournal of Cataract & Refractive Surgery, 2009
- Dissatisfaction after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009